Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação Honeywell, Modelo PRESSURETROL L404V

Fabricante : Honeywell
Arquivo Tamanho: 792.28 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


L404T,V PressureTrol® Controllers are for use on oil burner systems for pressures up to 1035 kPa or 150 psi. PRODUCT DATA FEATURES • Models available in a series of control ranges, and pressure scales in kPa and psi. • All models automatically reset and have an adjustabledifferential. • Models have snap switch to open or close a circuit ona pressure rise. • Case has a clear plastic cover so setpoints can beobserved. • 1/4 inch—18 NPT connection for pipe on diaphragm assembly. • Ground screw terminal. L404F: • Controllers may be used with steam, air, ornoncombustible gases, or fluids noncorrosive to the pressure sensing element. L404T: • High pressure limits, break a circuit on oil pressure rise above setpoint. L404V: • Low pressure limits, makes a circuit on oil pressurerise above setpoint. Contents Application ........................................................................ 1 Features ........................................................................... 1 Specifications ................................................................... 2 Ordering Information ........................................................ 2 Installation ........................................................................ 4 Settings and Adjustments ................................................. 6 Checkout .......................................................................... 7 71-2429-06 L404F,T,V PRESSURETROLL404F,T,V PRESSURETROL CONTROLLERS SPECIFICATIONS Model: L404F,T,V PressureTrol® Controllers. See Table 1. Table 1. Models with kPa—psi and Other Pressure Scales. Model Number Operating Ranges Subtractive Differentiala Maximum Diaphragm pressure kPa psi kPa psi kPa psi L404F1060 15 to 100 2 to 15 15 to 40 2 to 6 170 25 L404F1078 35 to 350 5 to 50 40 to 100 6 to 14 590 85 L404F1094 140 to 2070 20 to 300 140 to 345 20 to 50 2410 350b L404F1102 70 to 1035 10 to 150 70 to 150 10 to 22 1550 225 L404F1219c 15 to 100 2 to 15 15 to 40 2 to 6 170 25 L404F1243c 35 to 350 5 to 50 40 to 100 6 to 14 590 85 L404F1227c 70 to 1035 10 to 150 70 to 150 10 to 22 1550 225 L404F1235c 140 to 2070 20 to 300 140 to 345 20 to 50 2410 350b L404F1300c 415 to 1240 60 to 180 40 fixed 6.0 Fixed 1550 225 L404F1326 0 to 100 0 to 15 15 to 40 2 to 6 170 25 L404F1334 0 to 350 0 to 50 40 to 100 6 to 14 590 85 L404F1342 35 to 1000 5 to 145 70 to 150 10 to 22 1550 225 L404F1359 70 to 2000 10 to 290 140 to 345 20 to 50 2410 350b L404F1367 7 to 55 1 to 8 5 to 14 0.75 to 2 170 25 L404F1375d 35 to 350 5 to 50 40 to 100 6 to 14 590 85 L404F1383d 70 to 1035 10 to 150 70 to 150 10 to 22 1550 225 L404F1391d 140 to 2070 20 to 300 140 to 345 20 to 50 2410 350b L404F1409d 15 to 100 2 to 15 15 to 40 2 to 6 170 25 L404F1441 0.35 to 3.5 Kg/cm2 5 to 50 psi 0.4 to 1.0 Kg/cm2 6 to 14 psi 6 Kg/cm2 85 psi L404T1055 35 to 350 5 to 50 40 to 100 6 to 14 590 85 L404T1063 70 to 1035 10 to 150 70 to 150 10 to 22 1550 225 L404V1087d 70 to 1035 10 to 150 70 to 150 10 to 22 1550 225 L404V1095d 35 to 350 5 to 50 40 to 100 6 to 14 590 85 a Nominal at midscale operating range. b Brass bellows instead of stainless steel diaphragm. c Models with 1/4-19 BSPT thread instead of 1/4-18 NPT thread. d Make-on-rise models with terminal B omitted for miswiring compliance. ORDERING INFORMATION When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the TRADELINE® Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone: 1. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 1885 Douglas Drive North Minneapolis, Minnesota 55422-4386 In Canada—Honeywell Limited/Honeywell Limitee, 35 Dynamic Drive, Toronto, Ontario M1V 4Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 71-2429—06 2 L404F,T,V PRESSURETROLL404F,T,V PRESSURETROL CONTROLLERS Table 2. Conversion Table. Operating Range Conversions Subtractive Differential Conversions kg/cm2 kPa psi kg/cm2 kPa psi 0.1 to 1.05 15 to 100 2 to 15 0.15 to 0.4 15 to 40 2 to 6 0.4 to 3.5 35 to 350 5 to 50 0.4 to 1.0 40 to 100 6 to 14 0.7 to 10.0 70 to 1035 10 to 150 0.7 to 1.6 70 to 150 10 to 22 1.5 to 20.0 140 to 2070 20 to 300 1.5 to 3.5 150 to 300 20 to 50 Table 3. Switch Ratings (Amperes). Switch State 120 Vac 240 Vac Full Load 8.0 5.1 Locked Rotor 48.0 30.6 Pressure Sensing Element: Stainless steel diaphragm (140 to 2070 kPa models) has brass bellows. Maximum Ambient Temperature: 66°C (150°F). Also, refer to note under Mounting. Adjustment Means: Screws on top of control case. Scales are marked in psi or kPa. Mounting Means: 1/4 inch-18 NPT connection on diaphragm assembly; or surface mounts using holes in back of...

Este manual também é adequado para os modelos :
Monitores de pressão arterial - PRESSURETROL L404F (792.28 kb)
Monitores de pressão arterial - PRESSURETROL L404T (792.28 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias