Log:
Assessments - 2, GPA: 4 ( )

Instruções de Operação Panasonic, Modelo EW3153

Fabricante : Panasonic
Arquivo Tamanho: 2.4 mb
Arquivo Nome : EW3153.PDF
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


2. Press the Memory/Recall button. • The average readings of all recorded measurements are displayed. • When readings from 90 measurements have been saved the average of the readings from all 90 measurements will be displayed. (If there is only 1 measurement recorded, mark will not be displayed.) • The mark will be displayed. • Blood pressure indicator will be lit up for approximately 6 seconds. 3. Press the Memory/Recall button to display readings starting with from the most recent measurement. • Each time the Memory/Recall button is pressed readings are displayed in order of the most recent measurement. • The memory number, measurement date, and time are alternately displayed in approximately seconds. 4. Press the Adjust button “2” on the wireless display to switch off the unit. • If you forget to switch off the unit it will do so automatically after approx. 30 seconds. (After approx. 2 seconds.) (After approx. 2 seconds.) (After approx. 2 seconds.) 5 English Deleting all data stored in memory (1) Recall the user whom you want to delete using the user selection button. ( ) Recall stored data using the Memory/Recall button. (3) Press the Memory/Recall button again and hold it (for approx. 3 seconds) until all readings are deleted. NOTE: Readings from individual measurements cannot be deleted. (4) If everything has been deleted, the selected or mark and will be displayed. English 6 ComparingAMandPMAverageSystolicBloodPressure Average AM and PM systolic blood pressure is displayed in order to allow you to compare readings from both time periods. Use of the AM and PM average systolic blood pressure comparison function can aid in the detection of a blood pressure pattern known as “early morning surge” in which blood pressure rises rapidly in the morning. AM/PM comparison can only be done when the date and time have been set up. These can be compared after readings have been saved, and even when the unit is turned off. 1. Press the user selection button to select the user for a comparison of average AM and PM systolic blood pressures. • Each time the button is pressed the user switches from one to the other. 2. Press the button. • The average AM and PM systolic blood pressure for the selected user will be displayed. AM… 3:00 AM to 11:00 AM PM… 6:00 PM to :59 AM The average systolic blood pressure recorded during the time periods shown above will be displayed. When the time has not been recorded or a single reading has been recorded, “ ” will be displayed. • • 3.PresstheAdjustbutton“2”toswitchofftheunit. • If you forget to switch off the unit it will do so automatically after approx. 30 seconds. 7 English AfterUse Since the wireless display cannot be secured in place, be careful to avoid dropping the unit. 1 Tilt the main unit (using the handle) in the direction of the arrow until the unit is locked. 2 Place the wireless display on top of the unit securely. TotransporttheunitCarry the main unit and the wireless display separately. • English 8 Specifications Power source DC 6 V (Main unit: Four AA/LR6 size alkaline batteries) AC 1 0 V 60 Hz (when using AC adapter) DC 3 V (Wireless display: Two AA/LR6 size alkaline batteries) Display Digital LCD Method of measurement Oscillometric system Measurement range Blood pressure: 0 mmHg to 80 mmHg Pulse rate: 30 to 160 beats per minute Accuracy Blood pressure: Within ±3 mmHg Pulse rate: Within ±5% Operation temperature/ humidity range 10 °C to 40 °C (50 °F to 104 °F), 15% to 90% RH Storage temperature/ humidity range – 0 °C to 60 °C (–4 °F to 140 °F), 10% to 95% RH Measurable arm circumference Approx. 7.. to 13.. ( 0 cm to 34 cm) Weight Main unit: Approx. 1550 g (54.7 oz.) (not including batteries) Wireless display: Approx. 160 g (5.6 oz.) (not including batteries) Dimensions Main unit: 11.. . 6.. . 11.. ( 8.3 cm . 16.9 cm . 8.1 cm) Wireless display: 5.. . 3.. . .. (14.6 cm . 8.4 cm . 6.8 cm) Protection against electric shock Internally powered equipment, Type BF applied part AC adapter Input AC 1 0V 60 Hz Output DC 6V .0 A 9 English Q&A Q Why are the blood pressure values measured at home different from those measured at the doctor’s office? A Blood pressure varies in a 4-hour period. In addition, it can vary greatly depending on the weather, your mental state, amount of exercise, etc. In particular, there is the phenomenon of “White uniform hypertension” at doctor’s offices, where the blood pressure measured in a doctor’s office is higher because of stress or anxiety. In addition, if the blood pressure measured at home is sometimes higher and sometimes lower than the blood pressure measured at the doctor’s office, the following can be considered. Please pay attention to these points when taking measurements. 1 Measuring posture was poor. Did you take measurements while leaning forward with your body at an angle? Measurements were not taken at the upper arm. Please take measurements with your elbow in the arm support of the main unit. (See pages 15–17.) 3 Were you anxious...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias