Log:
Assessments - 4, GPA: 4 ( )

Instruções de Operação Braun, Modelo BP 2510

Fabricante : Braun
Arquivo Tamanho: 550.87 kb
Arquivo Nome : D6057_2_NA.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


If you have any questions, please call: 1-888-848-2572 Merci d'avoir achete un produit Braun. Nous esperons que votre nouveau Braun PrecisionSensor™ vous donnera toute satisfaction. En cas de questions, veuillez telephoner au : 1-888-848-2572 Gracias por comprar un producto Braun. Esperamos que se encuentre completamente satisfecho con su nuevo PrecisionSensor™. Si Ud. tiene preguntas, por favor llame al: Cd. de Mexico 01-800-53-87-19-41 Interior del pais 01-800-55-08-58-00 6-054-008/01/VII-01 USA/CDN/MEX Printed in Germany Imprime en Allemagne Impreso en Alemania D E F F A C B SYS mmHg 1 / min mmHg DIA Puls mem I/O G mem I/O G English Braun PrecisionSensor™ is a blood pressure monitor that has been developed for easy and accurate blood pressure measurements at the wrist. The measuring accuracy of the product has been tested at the time of manufacture and proven by clinical tests. Blood pressure monitors should always be positioned at an appropriate measuring position close to the heart for reliable measurements. The Braun PrecisionSensor™ has an active positioning system that guides your arm via arrows on its display to the medically recommended measuring position close to the heart. However, to ensure accurate results, carefully read these instructions. What you should know about blood pressure Blood pressure constantly changes throughout the day. It rises sharply in the early morning and declines during the late morning. Blood pressure rises again in the afternoon and finally drops to a low level at night. That is why readings can fluctuate when taken at different times of the day. SYS mm HG 140 120 100 60 6 5 h 12 18 0 80DIA mm HG Blood pressure readings from a healthy 31 year old male, measured at 5 minute intervals Blood pressure measured in a doctor’s office provides only a momentary value. Repeated measurements at home may be useful when monitoring one’s actual blood pressure values. Many people may have a different blood pressure reading when they measure at home, because they tend to be more relaxed than when in the doctor‘s office. Regular blood pressure measurements taken at home may provide your doctor with useful information on your «everyday» values. The World Health Organisation (WHO) has set up the following standard blood pressure values when measured at resting pulse. Blood pressure Normal Mild Severe (mm Hg) values hypertension hypertension SYS = systolic = upper value up to 140 140 – 180 over 180 DIA = diastolic = lower value up to 90 90 – 110 over 110 Important • This product is intended for household use only. Keep product and batteries away from children. • People suffering from cardiac arrhythmia, vascular constriction, arteriosclerosis in extremeties, diabetes or users of cardiac pacemakers should consult their doctor before measuring their blood pressure themselves, because deviations in blood pressure values may occur in such cases. • The active positioning system was developed based on anthropological studies conducted in Europe and is applicable for populations with comparable conditions. The system guides the user for repeatable measuring positions. • If you are under medical treatment or receiving medication, please consult your doctor. • The use of this blood pressure monitor is not intended as a substitute for consultation with your doctor. • Do not spill liquids on this device. Product description A Display (LCD) B Memory button (model BP 2510 only) C I/0 (on/off) button D Select button (position sensor) E Battery compartment F Battery compartment cover G Cuff Inserting batteries • Use only alkaline batteries of the type LR 03 (AAA) (e.g. Duracell-Ultra) as supplied with this product. • Remove the battery cover (F) and insert two batteries with correct polarity (see symbol in the battery compartment (E)). • New batteries (e.g. Duracell-Ultra) will provide approximately 300 measurements. • Only discard dead batteries. They should not be disposed of in household waste, but at appropriate collection sites. Key rules for accurate blood pressure measurement • Always take readings at the same time of day, ideally in the morning, under the same conditions. • Wait at least 30 minutes after smoking or after coffee or tea consumption before measuring. • While taking a measurement, sit down, relax, keep still, do not move or speak. • Hold the monitor at heart level. • Wait approximately 3 minutes before repeating a measurement. Measuring For blood pressure measurements at the wrist an appropriate measuring position close to the heart is essential for accurate results. 1. Fasten the monitor on your left arm on top of the slim side of your forearm (see illustration). Make sure the cuff (G) fits tight. Press the I/0 button (C). 2. Take the measuring position as shown. Your arms should remain close to your body. Make sure the monitor is approximately at heart level. 3a. When the monitor is at the appropriate measuring level, an acoustic signal will sound and the display will show a heart...

Este manual também é adequado para os modelos :
Monitores de pressão arterial - BP2005 (550.87 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias