Instruções de Operação HoMedics, Modelo BPA-300

Fabricante : HoMedics
Arquivo Tamanho: 2.21 mb
Arquivo Nome : 1b200e0f-b92f-41fb-bc5a-1893457b239d.pdf
Língua de Ensino: enes
Ir para baixar



Facilidade de uso


This monitor comes with two sizes of arm cuffs: Standard Size Fits 9.5"–14.2" (24 cm – 36 cm) Large Size Fits 13.4"–18.1" (34 cm – 46 cm) The appropriate cuff is suitable for your use if the colored arrow falls within the solid color line as shown below. If the Arrow falls outside of the Solid Color Line, you need a cuff with another circumference. For circumferences less than 9.5", contact HoMedics Consumer Relations. ARROW MUST FALL WITHIN YELLOW BAND ARROW MUST FALL WITHIN YELLOW BAND 9.5–14.2 Inches 24–36 Centimeters Standard Size Cuff Fits: Center tube over middle of arm MODEL# PP-BPCUFF5 Position cuff edge 0.6.–1.0. (1.5–2.5cm) above elbow. Center tube over middle of arm. Fit cuff securely. Allow room for two fingers to fit between the cuff and your arm. Solid Colored Line Colored Arrow BPA-300-A.qxd 10/5/06 4:20 PM Page 13 3. Open the arm cuff so that your arm may be placed through it. 4. Remove tight fitting clothing from around your upper left arm. 5. Position cuff edge 0.8-1.2 inches (2-3cm) above elbow. 6. Center tube over middle of arm. 7. Pull the end of the cuff so that it tightens evenly around your arm. Press the hook and loop material together to secure. Allow room for 2 fingers to fit between the cuff and your arm. 8. Lay your arm on a table (palm upward) so the cuff is at the same height as your heart. Make sure the tube is not kinked. 15 16 1. If the cuff is not assembled, pass the end of the cuff furthest away from the tubing through the metal D-ring in order to form a loop. The smooth side without the felt material should be on the inside of the cuff loop. 2. Plug the cuff tube into the left side of the unit. Position cuff edge 0.6.–1.0. (1.5–2.5cm) above elbow Center tube over middle of arm. F Insert plug here ARROW MUST FALL WITHIN YELLOW BAND D-ring End of cuff Felt Material on the outside of cuff BPA-300-A.qxd 10/5/06 4:20 PM Page 15 BPA-300-A.qxd 10/5/06 4:20 PM Page 17 Note: If it is not possible to fit the cuff to your left arm, it can also be placed on your right arm. However, all measurements should be made using the same arm. To use on the right arm, you must position the artery symbol “ ” over the main artery. Locate the main artery by pressing with two fingers approximately 1" (2 cm) above the bend of your elbow on the inside of your right arm. Identify where the pulse can be felt the strongest. This is your main artery. Main Artery 17 MEASUREMENT PROCEDURE Important Notes: • Blood pressure changes with every heartbeat and is in constant fluctuation throughout the day. • Blood pressure measurement can be affected by the position of the user, his or her physiologic condition and other factors. For greatest accuracy, wait 1 hour after exercising, bathing, eating, drinking beverages with alcohol or caffeine, or smoking to measure blood pressure. • Before measurement, it is suggested that you sit quietly for 15 minutes as measurements taken during a relaxed state will have greater accuracy. You should not be physically tired or exhausted while taking a measurement. • During the measurement, do not talk or move your arm or hand muscles. • See page 25 for additional notes regarding your blood pressure measurement. 18 BPA-300-A.qxd 10/5/06 4:20 PM Page 19 1. Press the User Select Button to choose User 1 or User 2. OR After the user number is selected, press the START/STOP button to confirm the chosen user. 2. With the cuff wrapped around your arm, press the START/STOP button. Do not inflate the cuff unless it is wrapped around your arm. All digits will light up to check the display functions. The checking procedure will be completed after about 2 seconds. STARTSTOP 19 3. After all symbols disappear, the display will show a blinking “0”. The monitor is “Ready to Measure” and will automatically inflate the cuff to start measurement. 4. Once your systolic pressure is determined, the monitor will begin deflating to measure your diastolic pressure. Note: This monitor will re-inflate automatically if the system detects that your body requires more pressure for measurement. 5. When the measurement is completed, the cuff will deflate entirely. Systolic pressure, diastolic pressure and pulse will be shown simultaneously on screen. The measurement is then automatically stored into memory. 20 BPA-300-A.qxd 10/5/06 4:20 PM Page 21 Note: 1. This monitor automatically turns off approximately 1 minute after last operation. You may also press the START/STOP button to turn the unit off. 2. To interrupt the measurement, you may press the START/STOP (recommended), “M”, User-Select or Date/Time Set buttons. The cuff will deflate immediately after a button is pressed. RISK CATEGORY INDICATOR The U.S. Department of Health and Human Services and the National Institutes of Health have developed a blood pressure standard classifying blood pressure ranges into 4 stages. This unit is equipped with an innovative blood pressure classification indicator, which visually indicates the assumed risk level (normal,...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias