Log:
Assessments - 4, GPA: 3.5 ( )

Instruções de Operação Omron Healthcare, Modelo BP785

Fabricante : Omron Healthcare
Arquivo Tamanho: 1.44 mb
Arquivo Nome : e0eece7b-5799-44b6-a99d-d0debf893625.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


AVERAGING FUNCTION The monitor calculates the average reading based on the three most recent sets of measurement values taken within 10 minutes of the most recent reading. NOTES: • If two sets of measurement values are stored in the memory for the 10 minutes period, the average is based on the two sets of measurement values. If one set of measurement values is stored, this is displayed as the average. • When viewing the reading taken without setting the date and time, “-:--” is displayed instead of the date and time. 36 USING THE MEMORY FUNCTION USING THE MEMORY FUNCTION TO DISPLAY THE MEASUREMENT VALUES 1. Select your USER ID (A or B). 2. Press the Memory button ( ). The Average Symbol ( ) appears on the display when the average reading is shown. 37 USING THE MEMORY FUNCTION USING THE MEMORY FUNCTION 3. Press the Down button ( ) to display the most recent set of measurement values on the screen. The values are displayed from the most recent to the oldest. NOTE: The date and time are alternately displayed with the measurement Alternating display values. Press the Up or Down button to display the next set of values. : To the older readings : To the more recent readings NOTE: Press and hold the Up or Down button to display the values faster. TruReadTM Mode The average for the consecutive measurements appears on the display with the TruReadTM symbol ( ). To display the values for the individual measurements press the SET button while the average is displayed. 4. Press the START/STOP button to turn the power off. 38 USING THE MEMORY FUNCTION USING THE MEMORY FUNCTION MORNING AND EVENING AVERAGES The monitor calculates and displays a weekly average for measurements taken in the morning ( ) and evening ( ). The monitor stores 8 weeks of Morning Averages and 8 weeks of Evening Averages for each user (A and B). NOTE: The week begins Sunday at 4:00 AM MORNING AVERAGES Morning averages are based on the first average reading using the TruReadTM Mode or the first reading using the Single Mode. Measurement times must be between: 4:00 AM and 9:59 AM. EVENING AVERAGES Evening averages are based on the last average reading using the TruReadTM Mode or the last reading using the Single Mode. Measurement times must be between: 7:00 PM and 1:59 AM. 39 USING THE MEMORY FUNCTION USING THE MEMORY FUNCTION TO DISPLAY MORNING AND EVENING AVERAGES 1. Select your USER ID (A or B). 2. Press the Morning/ Evening Average button ( ) to select the Morning or Evening average. The average for the current week “THIS WEEK” appears on the display. 3. Press the Down ( ) button to display the previous weeks. With each press of the Down ( ) button, the values are displayed from 1 week ago to the older. With each press of the Up ( ) button, the values are displayed from 7 week ago to the recent. NOTE: If no measurement is taken in a given week, the display will appear as illustrated. 4. Press the START/STOP button to turn the monitor off. 40 USING THE MEMORY FUNCTION USING THE MEMORY FUNCTION DISPLAY COMBINATIONS In addition to the Morning Average and Evening Average Symbols, the monitor may also display the Morning Hypertension Symbol if the morning average for that week is above the AHA guidelines. (See page 13 for details.) Depending on your measurement results, these may be displayed in the following combinations. Display Morning Average Morning average from This Week with Morning Average Symbol Morning average from 7 weeks ago with Morning Average Symbol + Morning Hypertension Symbol Evening Average Evening average from This Week with Evening Average Symbol Evening average from 7 weeks ago with Evening Average Symbol + Morning Hypertension Symbol Average within AHA guidelines Average above AHA guidelines + Morning Hypertension 41 USING THE MEMORY FUNCTION USING THE MEMORY FUNCTION The Morning Hypertension Symbol () appears if the weekly average for morning measurements is above 135/85. In this case the Morning Hypertension Symbol () is displayed when the Evening Average is displayed, regardless of the values for the Evening Average. TO DELETE ALL VALUES STORED IN THE MEMORY The values stored in the memory are deleted by USER ID. You cannot partially delete values stored in the memory. All values for the user you select will be deleted. 1. Select your USER ID (A or B). 2. While holding the Memory button ( ) and the START/STOP button simultaneously for more than 2 seconds all values will be deleted. 42 CARE AND MAINTENANCE CARE AND MAINTENANCE To keep your digital blood pressure monitor in the best condition and protect the unit from damage, follow the directions listed below: Keep the monitor in the storage case when not in use. Make sure the AC adapter is placed under the main unit so that it does not damage the display. Avoid kinking or sharply bending the AC Adapter cord. Do not forcefully bend the arm cuff or air tube. Do not fold tightly. Clean the monitor with a soft dry cloth. Do not use any abrasive or volatile cleaners. Do not attempt...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias