Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação Minolta, Modelo Pulsox-2

Fabricante : Minolta
Arquivo Tamanho: 1.28 mb
Arquivo Nome : pulsox2manual.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


This indicates text consisting of a warning or precaution relating to safety. Please read the text carefully and use the equipment safely. This indicates an action which is prohibited. The prohibited action should never be carried out, under any circumstances. This indicates instructions concerning an action. Always follow the instructions carefully. This indicates an action which is prohibited. Never disassemble the product or unit. This symbol indicates type BF applied part. The instrument provide a particular degree of protection against electric shock, particularly the leakage current and reliability of the protective earth connection with an F-TYPE APPLIED PART. F-TYPE APPLIED PART indicates applied part isolated from all other parts of the instrument to such a degree that the patient leakage current allowable in single fault condition is not exceeded when a voltage equal to 1.1 times the highest rated mains voltage is applied between the applied part and earth. IPX4 This symbol indicates Splash-proof equipment. Authorized Standards For North America UL, C_ UL: WITH RESPECT TO ELECTRIC SHOCK, FIRE AND MECHANICAL HAZARDS ONLY IN ACCORDANCE WITH UL 2601-1, CAN/ CSA C22.2 No.601.1 MEDICAL EQUIPMENT (70SA) For Europe CE (Medical Device Directive): This instrument complies with EN60601-1, EN60601-1-2, EN1441, EN46001. SAFETY PRECAUTIONS To ensure correct use of this instrument, read the following points carefully and adhere to them. After you have read this manual, keep it in a safe place where it can be referred to anytime a question arises. WARNING (Failure to adhere to the following points may result in death or serious injury.) Do not use the instrument in places where flammable or combustible gases (anesthetic gas etc.) are present. Doing so may cause a fire. Do not put the batteries on a fire, short-circuit them, heat them or disassemble them. Doing so may cause explosion or heat generation, resulting in fire or injury. This device is designed to measure the oxygen saturation level (SpO2) and the pulse rate. It should not be used as a warning device to detect cessation of breathing or irregular breathing during sleep. CAUTION (Failure to adhere to the following points may result in injury or damage to the instrument or other property.) Do not use batteries other than those specified by MINOLTA. When installing batteries in the instrument, make sure that they are correctly oriented according to the (+) and (–) marks. For a model which use more than one battery, do not mix new and old batteries, or mix batteries of different types. Failure to adhere to these instructions may cause explosion of the batteries or leakage of electrolyte, resulting in fire, injury or corrosion. Do not place the instrument on an unstable or sloping surface. Doing so may result in its dropping or overturning, causing injury. Take care not to drop the instrument when carrying it. Do not operate the instrument for long periods of time with a finger holder attached to a patient. Low-temperature burn, redness or rash may result. If you feel pain or itchiness, stop use of the instrument immediately and consult a doctor. A doctor should also be consulted before using the instrument on infants, those with peripheral blood circulation problems or those with sensitive skins. If alkali fluid from the battery comes in contact with eyes, skin, or clothing, immediately wash the affected area and see a physician for treatment. Do not use wet batteries. do not use instrument if the battery compartment contains water. Doing so may cause explosion or heat generation, resulting in fire or injury. Do not disassemble or modify the instrument. Doing so may cause a fire or electric shock 1. BEFORE OPERATION Safety Notes CAUTION: Federal law restricts this device to sale by or on the order of a physician. The PULSOX-2 is a medical instrument, so instructions given by a doctor must be adhered to. The instrument is designed for measurement of the oxygen saturation (SpO2) of arterial blood and the pulse rate. Do not use it for any other purposes, such as warning of sleep apnea and breathing abnormalities. Package Contents Make sure that all the following items are supplied with the instrument. 1 PULSOX-2 main unit (. 1) 2 Neck strap NS-M (. 1) 3 AAA-size alkaline battery (. 2) Main Features This pulse type oximeter emits light to the user’s finger to measure the oxygen saturation (SpO2 %) of arterial blood and the pulse rate. • Compact, lightweight and portable The light weight, compactness, and portability of the PULSOX-2 allows it to be used for inspection of both outpatients and inpatients. In addition, it is easily transported by both doctors and nurses for house calls or home- care patients. • Battery-operated The PULSOX-2 is operated by two AAA-size alkaline batteries. 2. NAMES OF PARTS n Main unit Finger holder Battery cover lock Strap eyelet Battery cover: Open or close this cover when replacing thebatteries with new ones. Battery cover: It is ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias