Log:
Assessments - 3, GPA: 3 ( )

Instruções de Operação Toshiba, Modelo MA-132 SERIES

Fabricante : Toshiba
Arquivo Tamanho: 872.75 kb
Arquivo Nome : 44bc6c0d-034f-4598-bea0-25f91dfadda5.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


The register will not operate in any position of the Control Lock unless one of these keys is inserted and set to the corresponding position on the Clerk Locks. Each of the keys may be inserted and pulled out in the neutral posiiton marked with (point). DISPLAY The front display is located at the top of the register just above the keyboard . FRONT DISPLAY PLU DPT RPT AMOUNT n f 3 1 ~t 1 U c r n □ U 1 L 1 1— 3 I _i o i u r f f T ▼ f T T ▼ SIP AL M REG (-) TXBL ST TL CG SHORT REAR or REMOTE DISPLAY NUMERIC DISPLAY AMOUNT (8 digits) RPT (1 digit): Displays the numeric data, such as amount, quantity, etc. Displays the repeat count of a Department or PLU item. It indicates nothing on the first item entry, showing 2, 3, 4, etc. from the second repeated item entry on. Since it has only one digit, 0 will be displayed for count 10, and 1 for 11, etc. DPT (1 digit): PLU (2 digits; one digit commonly used with the DPT digit): Displays the code No. which represents each Department Key. Displays the PLU code No. when a PLU item is entered. MESSAGE DESCRIPTORS (TRI-MARKS to appear) ▼ SLP: Appears when a validation slip has been properly inserted to allow validation. ▼ ALM: Appears with the alarm buzzer to indicate that the last operation or numeric entry has resulted in an error. To clear the error condition, depress the [c] key. ▼ REG: Appears when sale items have been entered. T (-): Appears when the |RTN MDSE], [DOLL DISCl, [Q, or | ITEM CORRl key has been operated. _ _ It also appears when the \ ST j , 1TXBL TL1 , or one of the total keys have been depressed and the displayed amount is negative. Y _ TXBL: Appears when a taxable item is entered or the [TXBL TL [ key is depressed. ▼ _ ST: Appears when the sub-total amount is displayed after the f ST] key has been depressed. Also appears when the [TXBL TL 1 key has been depressed. ▼ TL: Appears on a finalizing operation with the total amount displayed when a sale is finalized without any amount tendered. ▼ CG: When an amount tendering operation has been performed, this trimark appears with the change due displayed. ▼ SHORT: Appears when the amount tendered is less than the sale totaL with the shortage amount displayed. KEYBOARD LAYOUT The following are the Standard Keyboard Layout and two other variations of the MA-132 series, according to the tax requirements for different areas. Since this series is designed to be capable of programming many of the keys in the most desired location on the keyboard, please contact your TEC representative if any key is to change its location with another. STANDARD KEYBOARD (for a single-tax area) RECEIPT ON 0 Off CD -0 VALI DATE NS RF JF RCPT ISSUE DOLL DISC RTN MDSE X TX/M PLU # ITEM CORR C 7 8 9 4 5 6 1 2 3 0 00 I 1 2 R/A PO ST Chg TXBL TL CHK TEND AT/TL TYPICAL KEYBOARD FOR A DUAL-TAX AREA (Two Tax Modifier Keys Installed) VALI DATE #/NS RF JF RCPT ISSUE DOLL DISC RTN MDSE X TX1/M PLU TX2/M ITEM CORR C 7 8 9 5 6 1 2 3 0 00 i 1 2 R/A PO ST Chg TXBL TL CHK TEND AT/TL TYPICAL KEYBOARD FOR SINGLE-TAX AREA WITH MANUAL TAX ENTRY REQUIRED (One Tax Modifier Key and Manual Tax Key Installed) VALI DATE #/NS RF JF RCPT ISSUE DOLL DISC RTN MDSE X TX/M PLU TAX ITEM CORR C 7 8 9 4 5 6 1 2 3 0 00 i 1 2 R/A PO ST Chg TXBL TL CHK TEND AT/TL FUNCTION OF EACH KEY ON RECEIPT ON/OFF SWITCH M This switch has two positions available: "OFF" and "ON" positions. When in the "OFF" position, no receipt is issued from the register and sales are printed on the journal only. When the switch is set to the "ON" position, sales are printed on both receipt and journal rolls, then a receipt is issued which is cut and given to the customer. Alternating the switch position during a registration will not result in an error. In this case, the position set at the registration starting will rule whether a receipt is issued or not. When a reset (Z) report is taken, however, the data wiJJ. be printed also on the receipt roll regardless of the switch position. VALI DATE VALIDATION KEY This key is used to print a validation slip. To operate, insert a slip into the validation slot after registering the required item, and depress the I VALIDATE | key. The item and the amount will be printed on the slip. The system option provides program selections as to single- or multivalidation and consecutive No. print or non-print on the validation slip. NS NO-SALE KEY This key is used to open the cash drawer while the register is outside a sale in such occasions as giving change without relating to a sale. To operate, depress the [NS| key once. This key may also be operated to check the print condition on the receipt and journal. Usually, a non-add number cannot be entered prior to a no-sale operation within a receipt. However, it can be programmed to allow a nonadd number entry when a no-sale is operated. RF RECEIPT FEED KEY This key is used...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias