Log:
Assessments - 4, GPA: 3.5 ( )

Instruções de Operação Frymaster, Modelo CT16 Series

Fabricante : Frymaster
Arquivo Tamanho: 1.58 mb
Arquivo Nome : 6f91d1aa-b722-4d3e-b7b0-e7f29a354bb2.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


If not present, replace computer. Motor is running at wrong speed (i.e. average time for three individual buns to pass through toaster is NOT between 15 and 18 seconds). A. Toaster improperly configured for power supply. A. Check data plate for voltage rating, and verify that power supply and toaster match. A. Improper power-supply. A. Verify that the power supply is 20 amp single-phase 200, 208 or 240VAC (depending upon model). Platen heats, but unit does not reach setpoint. B. Failed temperature probe. B. Use a temperature-measuring device to determine actual platen temperature. If measured temperature is within 10 degrees of the temperature displayed on the computer and the probe resistance at pins 3 and 5 of the 9-pin connector does not correspond to the appropriate value in the probe resistance chart on Pages 24 and 25, replace the probe. C. Failed computer. C. Use a temperature-measuring device to determine actual platen temperature. If measured temperature is within 10 degrees of the temperature displayed on the computer and probe resistance at pins 3 and 5 of the 9-pin connector corresponds to the value in the probe resistance chart on Pages 24 and 25, replace the computer. 1-7 PROBLEM PROBABLE CAUSES CORRECTIVE ACTION Platen does not heat, but computer display is on. A. Failed computer. A. Check for 12VDC on computer pins 6 & 7. If NOT present AND motor is running, replace computer. Check for 5VDC on terminals 3 & 4 of main heater relay and pins 1 and 6 of computer. If NOT present at either point AND motor is running, replace computer. B. Broken/loose wire between computer and latch relay, or failed latch relay. B. Check for 12VDC on computer pins 6 & 7. If present and wiring is intact, replace latch relay. C. Failed main heater probe. C. Determine temperature of platen then measure main heater probe resistance at pins 3 & 5 of 9-pin connector. If the probe resistance is NOT approximately equal to the corresponding resistance in the chart on Pages 24 and 25, replace the probe. D. Broken/loose wire between computer and main heater relay, or failed main heater relay. D. Check for 5VDC on terminals 3 & 4 of main heater relay AND on computer pins 1 & 6. If present on pins 1 & 6, but NOT on terminals 3 & 4, and wiring is intact, replace the main heater relay. E. Failed platen. E. Check for 5VDC on terminals 3 & 4 of main heater relay and for line voltage on terminal 2 of main heater relay and terminal 4 of latch relay. If expected voltage is present at all three points, replace the platen. Probe Resistance Chart For use with CT16 Series toasters manufactured with Minco Thermistor probes only. F OHMS C F OHMS C F OHMS C F OHMS C F OHMS C 60 1059 16 160 1268 71 260 1473 127 360 1674 182 460 1872 238 65 1070 18 165 1278 74 265 1483 129 365 1684 185 465 1882 241 70 1080 21 170 1289 77 270 1493 132 370 1694 188 470 1892 243 75 1091 24 175 1299 79 275 1503 135 375 1704 191 475 1901 246 80 1101 27 180 1309 82 280 1514 138 380 1714 193 480 1911 249 85 1112 29 185 1320 85 285 1524 141 385 1724 196 485 1921 252 90 1122 32 190 1330 88 290 1534 143 390 1734 199 490 1931 254 95 1133 35 195 1340 91 295 1544 146 395 1744 202 495 1940 257 100 1143 38 200 1350 93 300 1554 149 400 1754 204 500 1950 260 105 1154 41 205 1361 96 305 1564 152 405 1764 207 505 1960 263 110 1164 43 210 1371 99 310 1574 154 410 1774 210 510 1969 266 115 1174 46 215 1381 102 315 1584 157 415 1783 213 515 1979 268 120 1185 49 220 1391 104 320 1594 160 420 1793 216 520 1989 271 125 1195 52 225 1402 107 325 1604 163 425 1803 218 525 1998 274 130 1204 54 230 1412 110 330 1614 166 430 1813 221 530 2008 277 135 1216 57 235 1422 113 335 1624 168 435 1823 224 535 2018 279 140 1226 60 240 1432 116 340 1634 171 440 1833 227 540 2029 282 145 1237 63 245 1442 118 345 1644 174 445 1843 229 545 2039 286 150 1247 66 250 1453 121 350 1654 177 450 1852 232 550 2049 288 155 1258 68 255 1463 124 355 1664 179 455 1862 235 1-8 1-9 1.5 Wiring Diagrams NOTE: These diagrams depict wiring as of the date of manual publication. They may not reflect design changes made to the equipment after publication. Always refer to the wiring diagram affixed to the unit when actually troubleshooting or servicing this equipment. NON-CE TOASTERS 1-10 CE AND AUSTRALIAN TOASTERS 1.6 Schematic 98 12Volt Secondary LINE VOLTAGE Cover Interloc k High Limit COM NO 1 2 3 5 4 Main Heater Probe 6 7 0 1 6 8 2 4 COMPUTER 3 4 Main Heater Relay Latch Relay Drive Motor Transformer 1 2 Resistor Main Heater Cartridge Heater LINE FILTER (CE AND AUSTRALIAN TOASTERS ONLY) M F Fan 1-11 THIS PAGE INTENTIONALLY LEFT BLANK. CT16 SERIES TOASTER SERVICE AND PARTS MANUAL CHAPTER 2: PARTS LIST 2.1 Introduction CT16 Toasters manufactured for use in the European Union (CE) and those manufactured for use elsewhere are identical in most respects, but there are some important differences. The paragraphs that follow summarize the differences and provide a list of the parts that are unique to each model. The most signifi...

Este manual também é adequado para os modelos :
Toasters - CT16 Series (1.58 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias