Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Sears, Modelo 831.28742

Fabricante : Sears
Arquivo Tamanho: 617.64 kb
Arquivo Nome : 99020115.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


831.287420 Serial No. Write the serial number in the space above for future reference. Serial Number Decal EXERCISE E(:;_ U IP M ENT HELPLINE! 1-800-736-6879 Patent Pending SEARS, ROEBUCK AND COo, HOFFMAN ESTATE_, I_ 1_017_1 TABLE OF CONTENTS IMPORTANT PRECAUTIONS .............................................................. 2 BEFORE YOU BEGIN ................................................................... 3 ASSEMBLY ........................................................................... 3 ADJUSTMENT AND OPERATION ........................................................... 6 MAINTENANCE AND TROUBLE-SHOOTING . ."................................................ 8 CONDITIONING GUIDELINES ............................................................. 9 PART LIST ........................................................................... 10 EXPLODED DRAWING ............................. "..................................... 11 ORDERING REPLACEMENT PARTS ............................................... .Back Cover WARRANTY .......................................................... _........ Back Cover 2 BEFORE YOU BEGIN Thank you for selecting the innovative SEARS LIFESTYLEFP CARDIO FORCE. The CARDIO FORCE offers a unique form of low-impact exercise that uses both the upper body and the lower body for increased cardiovascular benefits and greater toning results. For your benefit, read this manual carefully before you use the CARDIO FORCE. If you have additional questions, please call our toll-free HELPLINE at 1-800-736-6879, Monday through Saturday, 7 a.m. until 7 p.m. Central Time (excluding holidays). To help us assist you, please note the product model number and serial number when calling. The model number is 831.287420. The serial number can be found on a decal attached to the CARDIO FORCE (see the front cover of this manual). ASSEMBLY Place all parts of the CARDIO FORCE in a cleared • the included pedal tool (see the drawing below). area and remove the packing materials. Do not dispose of the packing matedals until assembly is com-PART CHART pleted. Read each step carefully before beginning. Use the drawings below to identify the small parts THE FOLLOWING TOOLS (NOT INCLUDED) ARE used in assembly. The number in parenthesis below REQUIRED FOR ASSEMBLY: each drawing refers to the key number of the part. The second number indicates the quantity needed for • one phillips screwdriver assembly. Note: Some small parts may have been pre- attached for shipping purposes. If a part is not found in • one adjustable wrench the parts bag, check to see if it has been pre-attached. • one rubber mallet Qq 3/4" x 2" Pedal Tool--1 1/2" Push Nut (30).--2 Note: Extra Push Nuts @ @ may have been included. 1/2" Dome Cap (29)--4 Note: One extra Dome Cap may have been included. 3/8" x 2 7/8" Carriage Bolt (35)--4 #6 x 3/8" Screw (16)--2 @8 3/8" Nylon Locknut (33)---4 1/4" x 2" Screw (17).--2 3 1. Find the Front Stabilizer (36), which has a decal on it. Make sure that there is a Large Round Endcap (8) on each end of the Front Stabilizer. Attach the Front Stabilizer (36) to the Frame (6) with two 3/8" x2 7/8" Carriage Bolts (35) and 3/8" Nylon Locknuts (33). Make sure that the indented holes in the Front Stabilizer are turned toward the frame. Attach the Rear Stabilizer (32) to the Frame (6) in the same manner. 2. Plug the Sensor Wire (15) into the back of the Monitor (1). Attach the Monitor to the bracket on the Frame (6) with the two #6 x 3/8" Screws (16). Make sure that the Sensor Wire is not pinched between the Monitor and the Frame. 3. IMPORTANT NOTE: Before assembling the 1/2" Dome Caps (29) in steps 3 and 4, be sun that all parts are oriented as shown in the drawings. The Dome Caps can be used only once; if the Dome Caps must be removed, it will be necessary to order new Dome Caps. Make sure that there are two 1/2" Pivot Bushings (20) in the indicated bracket on the Pedal Frame (7). Hold the Pedal Frame so the bracket is between the holes near the upper end of the Frame (6). Tap the 6" Pivot Rod (21) through the Pedal Frame and the Frame. Tap a 1/2" Dome Cap (29) onto each end of the Pivot Rod. 4. Make surethatthere isa 112"LinkArmBushing(19) in the end of each Link Arm (4) (see the inset drawing). Align the ends of the Link Arms with the indicated bracket on the Pedal Frame (7). Insert the 1 3/4" Rod (22) through the Link Arms and the bracket. Tap a 112" Dome Cap (29) onto each end of the Rod. 6 33 8 2 6 3 4 22 4 5. Attach the Seat (3) to the Seat Tube (5) with the two 1/4" x 2" Screws (17). Be sure that the Seat is oriented as shown. 3 6. Apply a small amount of grease to the two indicated shafts of the Pedal Frame (7). Slide a Pedal (12) onto the right shaft. Make sure that the Pedal is turned so the plastic tube is facing the Pedal Frame, as shown. Using the included pedal tool, tap a 1F2"Push Nut (30) onto the end of the shaft. Be sure that the Push Nut is turned as shown in the inset drawing. Attach the other Ped...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias