Log:
Assessments - 1, GPA: 5 ( )

Instruções de Operação Oregon Scientific, Modelo PM138E

Fabricante : Oregon Scientific
Arquivo Tamanho: 106.68 kb
Arquivo Nome : a4d7f0e7-91b1-47e6-963e-2c7403e0ea86.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Designed for ease-of-use, this product can be worn like a necklace or easily tied to a belt. A specially-designed wristband (optional feature) enables the product to be worn like a wristwatch. The unit's trouble-free qualities are enhanced through the products lightweight and small size. FEATURES 1. Pulse monitor 2. 12 /24 hr. real-time clock 3. Count-up / count-down timer 4. EL back light DESCRIPTION AND FUNCTION OF PARTS [FIG. A] A. LCD - Single-line, three-function display B. [MODE / SET] Button - Alternates between current-time and timer modes - Initiates settings changes C. Pulse Sensor - Detects a person's pulse rate D. [START / STOP] Button - To start or stop the count-up or count-down timer E. [PULSE ] Button - Sets the unit to pulse display from other display modes - Returns unit to previous mode from Pulse mode F. [ RESET / ADV] Button - Activates EL back light - Resets count-up / count-down timer - Increases values when setting the time or count-down timer G. Battery Compartment [FIG. B] - Insert one (1) CR2032 3V lithium cell BATTERY INSTALLATION: MAIN UNIT 1. Carefully unscrew the back panel. 2. Insert one (1) CR2032 3V lithium cell or equivalent [FIG. B]. 3. Replace the battery compartment door. Note: If not disposed properly, batteries can be harmful. Protect the environment by taking exhausted batteries to authorized disposal stations. WEARING THE PULSEMETER With the attached cord, the device can be worn like a necklace [FIG. C]. Alternately, the cord can be used to secure the device to a waist belt or clothing. Note: Optionally sold, a specially designed wrist strap worn in the same manner as a watch [FIG. D] and [FIG. E]. WEATHER RESISTANCE Designed for active outdoor use, this product is weather resistant and can be used under normal weather conditions. Avoid prolonged exposure to extreme weather conditions such as extreme cold or rain. ABOUT THE CLOCK In clock mode the unit will display the time. The time can be displayed in a 12-hour or 24-hour format as hours, minutes and seconds. To set the current time: 1. If the count-up / down timer is displayed, press [MODE / SET] to enter the clock mode [FIG F]. From pulse mode, press [PULSE ] to exit pulse mode followed by [MODE / SET] to toggle between clock and count up / down timer modes. 2. In clock mode, press and hold [MODE / SET] for two seconds. The 12-hour value will flash. 3. Press [ RESET / ADV] to make a selection between 12-hour and 24-hour format. 4. Press [MODE / SET], the hour digits will flash. 5. Press [ RESET / ADV] to advance the numbers until the appropriate hour digit is displayed. Holding down the button will increase the value rapidly. 6. Press [MODE / SET], the minute digits will flash. 7. Again, press [ RESET / ADV] to advance the numbers until the appropriate minute digit is displayed. 8. Press [MODE / SET], the "seconds" will flash. 9. Again, press [ RESET / ADV] to reset the "seconds" to zero. When the "seconds" correspond to the correct time and then press [MODE / SET] to confirm and exit. ABOUT THE TIMER The timer can count up from zero or count down from a pre-set time. Starting from zero the timer can count to a maximum time of 29-hours, 59- minutes, and 59-seconds (29:59' 59"). The unit will also count down from 29-hours, 59-minutes, and 59-seconds to zero. In count-down timer mode, once the unit reaches zero, if not stopped, the unit will continue and start counting upwards. To indicate that the unit is in count-up timer mode an up [ ] arrow will be displayed. Respectively, the count-down mode display is indicated by a down [ ] arrow. To use the count-up timer: 1. If the clock is displayed, press [MODE / SET] to enter the count-up / down timer mode [FIG. G]. From pulse mode, press [PULSE ] to exit pulse mode followed by [MODE / SET] to toggle between clock and count-up / down timer modes. 2. If the count-up timer display does not show zero hours, minutes, and seconds, Press and hold [RESET] for 2 seconds to reset the count-up timer to zero. 3. Press [START / STOP] to start the timer. 4. Press [START / STOP] again to stop and pause the timer. 5. Press and hold [RESET] for 2 seconds to reset the timer to zero. To use the count-down timer: 1. If the clock is displayed, press [MODE / SET] to enter the count-up / down timer mode [FIG. H]. From pulse mode, press [PULSE ] to exit pulse mode followed by [MODE / SET] to toggle between clock and count-up / down timer modes. 2. To set the count-down timer, press and hold [MODE / SET] for 2 seconds, the hour digits will flash. 3. Press [ RESET / ADV] to advance the numbers until the appropriate hour digit is displayed. Holding down the button will increase the value rapidly. 4. Press [MODE / SET], the minute digits will flash. 5. Again, press [ RESET / ADV] to advance the numbers until the appropriate minute digit is displayed. 6. Press [MODE / SET], the "seconds" will flash. 7. Again, press [ RESET / ADV] to advance the numbers until the appropriate minute digit is displa...

Este manual também é adequado para os modelos :
Formadores - PM138 (106.68 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias