103 SMOOTH is a registered trademark of Internetfitness.com Mt. Laurel, NJ Important Safety Instructions Important Safety Instructions WARNING! Read all instructions before using this appliance. DANGER - To reduce the risk of electric shock disconnect your treadmill from the electrical outlet prior to cleaning and/or service work. WARNING -To reduce the risk of burns, fire, electric shock, or injury to persons, install the treadmill on a flat level surface with access to a 120-volt, 20-amp grounded outlet. DO NOT USE AN EXTENSION CORD: DO NOT ATTEMPT TO DISABLE THE GROUNDED PLUG BY USING IMPROPER ADAPTERS, OR IN ANY WAY MODIFY THE CORD SET. A serious shock or fire hazard may result along with computer malfunctions. See Grounding Instructions, page 2. • Do not operate treadmill on deeply padded, plush or shag carpet. Damage to both carpet and treadmill may result. • Do not block the rear of the treadmill. Provide a minimum of 3 1/2 feet clearance between the rear of the treadmill and any fixed object. • Keep children away from the treadmill. There are obvious pinch points and other caution areas that can cause harm. • Keep hands away from all moving parts. • Never operate the treadmill if it has a damaged cord or plug. If it is not working properly, call your dealer. • Keep the cord away from heated surfaces. • Do not operate where aerosol spray products are being used or where oxygen is being administered. • Never operate the treadmill with the air openings blocked. Keep the air openings free of lint, hair, and the like. • Never drop or insert any object into any openings. • Do not use outdoors. • To disconnect, turn all controls to the off position, remove tether cord, then remove plug from outlet. • Do not attempt to use your treadmill for any purpose other than for the purpose it is intended. • Use handrails provided; they are for your safety. • Wear proper shoes. High heels, dress shoes, sandals or bare feet are not suitable to be used on your treadmill. Quality athletic shoes are recommended to avoid leg fatigue. Remove tether cord after use to prevent unauthorized treadmill operation. SAVE THESE INSTRUCTIONS - THINK SAFETY! 1 Important Electrical Information Important Electrical Information WARNING! • NEVER use a ground fault circuit interrupt (GFCI) wall outlet with this treadmill. • Route the power cord away from any moving part of the treadmill including the elevation mechanism and transport wheels. • NEVER remove any cover without first disconnecting AC power. • If voltage varies by ten percent (10%) or more, the performance of your treadmill may be affected. Such conditions are not covered under your warranty. If you suspect your voltage is low, contact your local power company or a licensed electrician for testing. See Diagnosis Guide, page 13. • NEVER expose this treadmill to rain or moisture. This product is NOT designed for use outdoors, near a pool or spa, or in any other high humidity environment. Grounding Instructions This product must be grounded. If it should malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This product is equipped with a cord having an equipment-grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances. DANGER - Improper connection of the equipment-grounding conductor can result in a risk of electric shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the product is properly grounded. Do not modify the plug provided with the product - if it will not fit the outlet, have a proper outlet installed by a qualified electrician. This product is for use on a nominal 120-volt circuit, and has a grounding plug that looks like the plug illustrated in sketch A. A temporary adapter that looks like the adapter illustrated in sketches B and C may be used to connect this plug to a 2-pole receptacle as shown in sketch B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet (sketch A) can be installed by a qualified electrician. The green colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box cover. Whenever the adapter is used, it must be held in place by a metal screw. Grounded Outlet Adapter Grounding Pin Grounded Outlet Box Tab for Grounding ScrewMetal Screw A B C 2 Treadmill Assembly Treadmill Assembly Attention! The following instructions are included only as information so that you, the consumer, understand basically how the treadmill is assembled. STEP 1: Remove treadmill from carton. You may pick the rear of the treadmill up and roll it off the packaging. Remove foam padding, wrap, etc. Observe for possible freight damage. Note: You will need a phillips screw driver and 1/2” wrench to complete assembly. STEP...