|
Facilidade de uso
Mattress MUST fit bed frame and side rails snugly to prevent patient entrapment. Follow the manufacturer’s instructions. Monitor patient frequently. Read and understand the Owner’s/Operator’s Manual prior to using this equipment. Invacare product manuals are available at or your dealer. • Refer to the instructions provided with the side rails for the installation procedure. Part No 1148138 15 Invacare®MA80 Series Mattresses 4 OPERATION 4.3 Installing the Control Unit Bed Hook 1. Pull out the bed hook on the back of the control unit. 2. Place the control unit on the footboard. If the bed does not have a footboard, place the • control unit on a flat surface, leaving room for the hose to hang down. FIGURE 2 Installing the Control Unit 4.4 Connecting the Hose CAUTION . Ensure that the hose connecting the control unit to the mattress is routed such that it cannot be stepped on, kinked, squeezed or otherwise damaged. 1. Locate the hose at the foot end of the mattress. 2. Locate the control unit connector on the right side of the control unit. 3. Lift and hold the connector cover up. 4. Push the hose connector (Detail “A”) onto the control connector. Invacare®MA80 Series Mattresses 16 Part No 1148138 4 OPERATION 5. Ensure the hose connector is flush with the control unit connector. Control Unit DETAIL “A” Connector Cover Hose Control Unit Holes Connector Connector FIGURE 3 Connecting the Hose 4.5 Connecting the Power Cord WARNING . DO NOT alter plug to fit a non-conforming outlet. Instead, have an electrician install a properly grounded outlet. Failure to use the correct plug and outlet can result in a potential safety hazard. CAUTION Ensure that the power cord of the control unit is not pinched, or has any objects placed on it, and also ensure it is not located where it can be stepped on or tripped over. Part No 1148138 17 Invacare®MA80 Series Mattresses 4 OPERATION 1. Examine the hospital grade power cord supplied with the control Control Unit unit. 2. Perform one of the following: • If the plug is damaged - Call your supplier for a replacement hospital grade cord. • If the plug is not damaged - Plug the end of the supplied hospital grade power cord into the power outlet on the side of the control unit. Power 3. Plug the other end of the plug into a properly grounded outlet on the wall. Outlet Once the unit is plugged in, an AMBER LED on the • control unit is lit indicating that the system is in STAND BY mode. FIGURE 4 Connecting the Power Cord Invacare®MA80 Series Mattresses 18 Part No 1148138 4 OPERATION 4.6 Using the Front Panel DETAIL “A” - MA80 Fowler Button Power Fail LED Low Pressure LED Pulse Button Power Button Static Button Soft Button Max Inflate Button FRONT PANEL Lock/Alarm Button LCD Display Firm Button Low Pressure LED DETAIL “B” -Alternating Pressure Button Power Fail LED MA85 FRONT PANEL Power Button Static Button Firm Button Soft Button Fowler Button Max Inflate Button Lock/Alarm Button LCD Display FIGURE 5 Using the Front Panel Part No 1148138 19 Invacare®MA80 Series Mattresses 4 OPERATION Power Button 1. To turn the control unit on or off, press and release the Power button ( ). Once the unit is plugged in, an AMBER LED on the control unit is lit indicating that the system is in STAND BY mode. Once • the Power button is pressed and released, a GREEN LED illuminates indicating that the control unit is on. If the power comes on after a power outage, the control unit will go through its system initialization routine for a few seconds and then resume the desired function. Pulse Button (MA80 Power Unit) 1. Press the Pulse button ( ) to turn on Pulse mode and select one of four Pulse Times - 1, 3, 5 or 10 minutes. The pulse times are 1, 3, 5 or 10 minutes. The pulse times indicate the time between each low pulse. For example, if 5 • minutes is selected, all the air cushions in the mattress will inflate for 5 minutes (the selected time) to the selected comfort setting and then drop 20% pressure for 20 seconds. Alternating Pressure Button (MA85 Power Unit) 1. Press the Alternating Pressure button ( ) to select one of four alternating pressure modes. The alternating pressure times indicate the frequency of deflation or inflation of half of the air cushions (even or odd • numbered). For example, 10 minutes is selected. For example, 10 minutes is selected. In this example, the even numbered air cushions in the mattress will deflate, while the odd numbered cushions remain at constant pressure. When 10 minutes has elapsed, the even numbered air cushions will inflate while the odd numbered cushions remain at constant pressure. When 10 minutes has elapsed again, the odd numbered air cushions deflate while the even numbered cushions remain at constant pressure. The air cushions continue to inflate or deflate like this as long as an alternating pressure time has been selected. At all times, half of the air cushions remain at a constant pressure when an alternating pressure time has been selec...
Este manual também é adequado para os modelos :Travel Gear - MA85 (2.5 mb)