MSA7X Series Enclosure

About this document
Backplane replacement
This document details procedures for replacing a failed
backplane in an MSA7X Series Enclosure.
instructions
Before you begin

For updates, visit the HP website:
CAUTION: Before removing the failed component, make sure
http://www.hp.com/support/manuals.
that you have the replacement part available. Removing a
component impacts the airflow and cooling ability of the

device.
To prevent improper cooling and thermal damage, do not
operate the storage enclosure unless all bays are populated
with either a component or a blank.

Do not remove more than one component or blank from the

enclosure at a time. Doing so impacts the airflow and cooling
ability of the device. To avoid possible overheating, insert the

new or replacement component as quickly as possible. If the
internal temperature exceeds acceptable limits, the enclosure

may overheat and automatically shut down or restart.

Parts can be damaged by electrostatic discharge. Use proper

anti-static protection.


Verifying component failure


Before replacing the midplane, use the following methods to
verify component failure:


Check the following component status LEDs as identified in

the following tables:

• Hard drives—test with known good hard drives.

• I/O module—test with known good I/O module.

• Fan module—test with known good fan module.

Check the host log for errors.



Hard drive LED combinations

Online/activity LED Fault/UID LED
Interpretation
(green)
(amber/blue)

On, off, or flashing Alternating amber
The drive has failed, or

and blue
a predictive failure

alert has been received
for this drive; it also

has been selected by a
© Copyright 2007 Hewlett-Packard Development Company, L.P.
management
application.
The information contained herein is subject to change without notice.
The only warranties for HP products and services are set forth in the
On, off, or flashing Steadily blue
The drive is operating
express warranty statements accompanying such products and services.
normally, and it has
Nothing herein should be construed as constituting an additional
been selected by a
warranty. HP shall not be liable for technical or editorial errors or
management
omissions contained herein.
application.

On
Amber, flashing
A predictive failure
Part number: 436513-001
regularly (1 Hz)
alert has been received
for this drive.
First edition: 02/2007
Replace the drive as
*436513-001*
soon as possible.
On Off The drive is online, but

it is not currently active.


...

Este manual também é adequado para os modelos :
dados de dispositivos de processamento - HP MSA70 Dual Domain (25) 300GB 2.5-inch DP SAS HDD 7.5TB Bundle (506.04 kb)
dados de dispositivos de processamento - HP StorageWorks MSA70 with 25 72GB SAS SFF 1.8TB Bundle (506.04 kb)
dados de dispositivos de processamento - HP StorageWorks MSA70 with 25 146GB SAS SFF 3.6TB Bundle (506.04 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias