Fabricante : HP
Arquivo Tamanho: 441.64 kb
Arquivo Nome :
|
por este dispositivo também tem outras instruções :
Facilidade de uso
Table 1 Controller status LEDs
1.
Halt I/O to the controller with HP P6000
Command View:
Item
LED
Indication
a.
In the navigation pane, select Storage
1
Blue LED identifies a specific controller
System→Hardware→Controller Enclosure.
module within the enclosure.
b.
Select the controller (Controller 1 or
2
Green LED indicates controller health.
Controller 2) to halt.
LED flashes green during boot and
c.
Click the Shut down tab.
becomes solid green after boot.
d.
In the Halt Controller section of the Shut
3
Flashing amber indicates a controller
Down Controller window, click Halt. This
termination, or the system is
halts controller processing while the power
inoperative and attention is required.
Solid amber indicates that the
remains on.
controller cannot reboot and that the
2.
Disconnect the SAS, Fibre Channel, Ethernet, and
controller should be replaced. If both
console cables from the halted controller. Ensure
the solid amber and solid blue LEDs
are lit, the controller has completed a
they are marked to facilitate reconnecting later.
warm removal procedures, and can
3.
Remove the controller.
be safely swapped.
a.
Loosen the thumbscrew on the mounting latch
4
MEZZ
Indicator is not used on FC controller.
and rotate the latch to the right (1,
The indicator is used on the FC-iSCSI
Figure 3 (page 3)).
or iSCSI/FCoE controller to indicate
iSCSI module status.
The controller will slightly eject from the
enclosure.
5
Green LED indicates write-back cache
status. Slow flashing green LED
b.
Position one hand under the controller, and
indicates standby power. Solid green
with the other hand, pull the controller out of
LED indicates cache is good with
the enclosure (2).
normal AC power applied.
6
Amber LED indicates DIMM status. The
Figure 3 Removing a controller
LED is off when DIMM status is good.
Slow flashing amber indicates DIMMs
are being powered by battery (during
AC power loss). Solid amber indicates
a DIMM failure.
Removing a controller
CAUTION:
Verify the location of the controller
being serviced. Removing the wrong controller
can result in data loss.
NOTE:
•
Replacement controllers do not have DIMM
4.
Push the blue button on top of the controller
modules, therefore the DIMMs from the
module (1, Figure 4 (page 4)) and slide off the
controller being removed must be
cover (2). Observe proper anti-static guidelines.
transferred to the replacement controller.
•
HP recommends that you replace the
controller while the controller enclosure is
powered on to ensure the controller
software on the redundant controller is
copied to the controller being installed.
Page 3
... Este manual também é adequado para os modelos :
dados de dispositivos de processamento - HP EVA P6350 450GB 10K SAS FIO Starter Kit (441.64 kb)
dados de dispositivos de processamento - HP EVA P6350 900GB 10K SAS Field Starter Kit (441.64 kb)
dados de dispositivos de processamento - HP EVA P6350 900GB 10K SAS FIO Starter Kit (441.64 kb)
dados de dispositivos de processamento - HP EVA P6350 EVA FC/1GbE SFF Combo Factory Kit (441.64 kb)