Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação HP, Modelo HP EVA3000 Disk Array

Fabricante : HP
Arquivo Tamanho: 112.67 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Fibre Channel disk
HP model displayed in
Minimum supported
Recommended
HP Command View EVA
firmware version
firmware version
ND2505823A
HP00
HP04
250GB
ND25058238
HP00
HP04
400GB
NB40059392
HP02
HP03
500GB
NB50058855
HP02
HP03
Important notes and workarounds
This section identifies important notes and workarounds specific to the EVA3000/5000 hardware and
VCS software. Operating constraints for related software applications are included in the following
documents:
HP StorageWorks Command View EVA release notes
HP StorageWorks EVA replication software consolidated release notes
These documents can be downloaded from the following website:
ht p://www.hp.com/support/manuals
Click Storage Software under storage and then select your product.
Information on avoiding problem situations specific to operating systems can be found in the individual
operating system release notes. See “Supported operating system specifications” on page 6.
Connecting an EVA3000/5000 to a 4 GB McData switch
When connecting an EVA3000/5000 to a 4 GB-capable McData switch, do not connect any of the EVA
ports to port 0 on the McData switch. Otherwise, the storage system will not start up.
The port 0 restriction will remain effective until a firmware fix is available.
Login failure occurs for EVA connected to a Brocade 4100 switch with 2 GB
SFP cables
An EVA3000/5000 running VCS 4.100 that is connected to a Brocade 4100 switch with 2 GB SFP
cables may intermittently experience a login failure. This issue is not experienced if the Brocade switch
has 4 GB SFP cables.
To resolve this issue, do one of the following:
• Power down and then power up the storage system.
• Remove the cable from the port that is experiencing the login failure and then reconnect it.
Disk Resource Pending Timeout for Microsoft Windows cluster configurations
If the disk resource count is greater than 8, HP recommends increasing the Pending Timeout parameter
for each disk resource from 180 seconds to 360 seconds. Increasing the timeout value helps maintain
continuous operation of disk resources across SAN perturbations.
To view and set the Pending Timeout parameter:
1. Open the Microsoft Cluster Administrator.
2. Select a disk group resource in the left pane.
3. Right click each disk resource in right pane, one at a time, and select Properties.
4. Select the Advanced tab from the Properties menu.
5. Locate the Pending Timeout value and change it to 360.
8


...

Este manual também é adequado para os modelos :
dados de dispositivos de processamento - HP StorageWorks EVA3000 EMEA Bundles (112.67 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias