Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Antari Lighting and Effects, Modelo DNG-100

Fabricante : Antari Lighting and Effects
Arquivo Tamanho: 68.49 kb
Arquivo Nome : 14023e36-82f8-2d24-fd40-89f7d11d4770.pdf
Língua de Ensino: enfrde
Ir para baixar



Facilidade de uso


2004 Antari Lighting and Effects Ltd. User Manual Antari Fog Cooler Congratulations on the purchase of your new ANTARI FOG COOLER Introduction Thank you for choosing the ANTARI Fog Cooler. You now own a rugged and powerful state-of-the-art machine. Prior to use, we suggest that you carefully read all of the instructions. By following the suggestions found in this user manual, you can look forward to the reliable and satisfactory performance of your ANTARI Fog Cooler for years to come. Please follow these operation, safety and maintenance instructions to ensure a long and safe life for your fog cooler. Pay attention to all warning labels and instructions printed on the exterior of your ANTARI Fog Cooler ¦ Ideal operating temperature is 10 - 30 degrees Celsius. ¦ After moving or transporting this unit, wait five minutes before operating. ¦ Input fog must be clean. Contaminated fog may damage internal parts. ¦ There must be a free air space of at least 15 cm (6 inches) between the fog cooler intake and the fog machine output. ¦ After interrupting operation, wait three minutes before starting again. ¦ Keep this device dry. ¦ For inside use only. Not designed for outside use. ¦ For the 110V models, use 3-prong grounded electrical outlet only. Prior to use take care to determine that the unit is installed at the rated voltage. ¦ Keep fog cooler upright. Do not tilt this device. Angle of inclination may not exceed 10 degrees. ¦ Turn off or unplug when not in use. ¦ This machine is not water- or splash-proof. If moisture, water, or fog liquid gets inside the housing, immediately unplug the unit and contact a service technician or your ANTARI dealer before using it again. ¦ No user serviceable parts inside. Refer to your ANTARI dealer or other qualified service personnel. ¦ For adult use only. Fog cooler must be installed out of the reach of children. Never leave the unit running unattended. ¦ Locate the fog cooler in a well-ventilated area. Never cover the unit’s vents. The fog cooler is best installed 1 meter away from all objects. ¦ Use only ANTARI FLR Fog Liquid. ¦ If your ANTARI Fog Cooler fails to work properly, discontinue use immediately. Pack the unit securely (preferably in the original packing material) and return it to your ANTARI dealer for service. Unpacking & Inspection Open the shipping carton and verify that all equipment necessary to operate the system has arrived intact. Refer to the ”Features” section for information on what 2 items are included with your model. If any equipment is missing contact your ANTARI dealer immediately. Before beginning initial setup of your ANTARI Fog Cooler, make sure that there is no evident damage caused by transportation. In the event that the unit’s housing or cable is damaged, do not plug it in and do not attempt to use it until after contacting your ANTARI dealer for assistance. Setup ¦ Remove all packing materials from shipping box. Check that all foam and plastic padding is removed, especially in the nozzle area. ¦ Attach power cord to rear of fog cooler. ¦ Place the fog cooler’s intake within six inches (15 cm) of a fog machine’s output. ¦ Plug power cord into a grounded electrical outlet. Turn power switch on rear of unit to ”ON” position. ¦ Waiting time for cooling is approximately two minutes. Operation ¦ ANTARI Fog Cooler’s output volume is determined by the output volume of the fog machine to which it is attached. ¦ Your ANTARI dealer has the hoses and adapters required for an optimal installation of the fog cooler. See the two illustrations below: In the first example, a fog conducting hose (FT-10) is attached to a fog machine’s output nozzle via an adapter (FTA-1 or FTA-2) and then connected to an adapter (FTA-10) attached to the fog cooler’s intake. In the second example, substitute the guide plate (FTA-12) with a fog conducting hose (FT-10) that attaches to the front of the fog cooler via an adapter (FTA-11). This configuration allows the fog cooler’s output to be guided to a desired area without being affected by air currents generated by movement, wind, fans or air conditioners. 3 During operation, if you experience mechanical noise or no output, unplug immediately. Check power connections and fog machine operation. Wait three minutes and then plug the unit in again. After plugging the unit in and turning it on, wait for two minutes. If the problem persists, discontinue operation and return the machine to your ANTARI dealer. Maintenance Clean the water carrier regularly to avoid overflowing. Clean with a damp cloth. Store in a dry place. Save these instructions 4 Bedienungsanleitung Bedienungsanleitung Antari Nebelkuhler Wir begluckwunschen Sie zum Kauf Ihres neuen ANTARI NEBELKUHLERS. Einfuhrung Danke, da. Sie sich fur den ANTARI Nebelkuhler entschieden haben. Damit besitzen Sie nun ein robustes und leistungsstarkes Gerat mit modernster Technik. Bitte lesen Sie vor dem Gebrauch des Gerates sorgfaltig alle Anweisungen. Wenn Sie die Anweisungen in di...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias