Log:
Assessments - 6, GPA: 4 ( )

Instruções de Operação Bionaire, Modelo BU5210-CN

Fabricante : Bionaire
Arquivo Tamanho: 585.71 kb
Arquivo Nome :
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


6. Plug the humidifier into a 120V electrical outlet. OPERATING INSTRUCTIONS 1. To turn the humidifier on, switch the Slider Wheel to produce the highest moisture level. A lower setting will produce lower moisture level but with longer run time (for BU5110 only). The detailed settings for each model are shown as below: BU5110: Low ( ) High BU5210: Off (O) - On ( ) 2. When the humidifier runs out of water, the transducer will automatically shut off and the fan will keep running to dry any residual water out of the base and chamber. 3. Once the tank is empty, turn the Slider Wheel to the Off position and unplug the unit. 4. Before refilling the tank, empty any residual water from the base and tank. Follow daily maintenance instructions. 5. Fill tank with cool, fresh tap water. DO NOT fill with warm water as this may cause leaking. Replace the cap on tank FIRMLY. Follow step 5-6 in pre-operating instructions. WARNING: Do not tilt, move, or attempt to empty unit while it is operating. Shut off and unplug before removing the water tank and moving the unit. IMPORTANT: If you do not plan to use your humidifier for two or more days, make sure any residual water is drained from the water tank and base to prevent any algae or bacteria growth in stagnant water. Make sure the tank is dry. NOTE: This humidifier is equipped with an agency required overflow feature. To prevent spillage or overflow of water, avoid tilting the humidifier while carrying. CLEANING AND MAINTENANCE INSTRUCTIONS Humidifiers provide comfort by adding moisture to dry, heated indoor air. To benefit most from the humidifier and avoid product misuse, follow all instructions carefully. Please note that this is an electrical appliance and requires attention when in use. In addition, if you do not follow the recommended care and maintenance guidelines, micro-organisms may be able to grow in the water within the humidifier's tank. You must routinely follow the cleaning procedures that follow in order to ensure proper, efficient operation of your humidifier. Proper maintenance and cleaning is essential to the continued performance of your unit and the avoidance of algae or bacteria build-up. DAILY MAINTENANCE 1. Be sure the unit is OFF and is disconnected from the electrical outlet. 2. Remove the tank from the humidifier and place in sink or tub. 3. Drain any remaining water and rinse thoroughly to remove any sediment or dirt. Wipe clean and dry with a clean cloth or paper towel. 4. Refill with cool tap water. Do not overfill. WEEKLY MAINTENANCE To Remove Scale: 1. Repeat steps 1-3 above. 2. Clean the base by partially filling it with one 8-oz (0.24 litre) cups of undiluted white vinegar or by using Clean-AwayTM solution (model DMS216) by the manufacturer. Leave this solution in the tank for 20 minutes, while cleaning all interior surfaces with a soft brush (brush not included). Gently scrub the area around the transducer with a soft brush. Remove the scale by wiping the entire base with a cloth dampened with undiluted white vinegar. 3. Rinse clean with warm water to remove cleaning solution before disinfecting the tank. To Disinfect Tank 1. Fill humidifier tank 1/2 full with water and 1/2 tablespoon of chlorine bleach. 2. Let the solution stand for 20 minutes, swishing every few minutes. Wet all surfaces. 3. Carefully empty the tank after 20 minutes, and rinse with warm water until you cannot detect any bleach smell. Dry with a clean cloth or paper towel. 4. Refill the water tank as directed in Operating Instructions, and turn the unit on. STORAGE INSTRUCTIONS When not using your humidifier for an extended period of time: 1. Clean, rinse and thoroughly dry the humidifier as directed in weekly maintenance. DO NOT leave any water in the unit when storing. Leaving water in the unit may render the unit inoperable for the following season. 2. Place the humidifier in the original carton and store in a cool, dry place. REPLACEMENT ACCESSORIES To order the replacement accessories you can do any of the following: • Visit your local retailer • Go to • Call consumer service at 1-800-253-2764 SERVICE INSTRUCTIONS Do NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void the warranty. The inside of humidifier contains no user serviceable parts. All servicing should be performed by qualified personnel only. Should your humidifier require service, please call 1-800-253-2764 in North America for further assistance. 1 YEAR LIMITED WARRANTY Sunbeam Products, Inc. doing business as Jarden Consumer Solutions or if in Canada, Sunbeam Corporation (Canada) Limited doing business as Jarden Consumer Solutions (collectively “JCS”) warrants that for a period of one year from the date of purchase, this product will be free from defects in material and workmanship. JCS, at its option, will repair or replace this product or any component of the product found to be defective during the warranty period. Replacement will ...

Este manual também é adequado para os modelos :
Umidificadores - BU5110-CN (585.71 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias