Log:
Assessments - , GPA: ( )

Instruções de Operação Essick Air, Modelo 4D7 300

Fabricante : Essick Air
Arquivo Tamanho: 307.76 kb
Arquivo Nome :

Língua de Ensino: enesfr

O documento está colocado, por favor, espere
O documento está colocado, por favor, espere

Facilidade de uso


If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. If an extension cord must be used, it should also accept the wide blade plug and meet this electrical rating. 2) Do not place the cord under rugs, near loose drapes, in traffic areas, nor near heat sources or combustible materials. 3) Do not use the humidifier if the cord is damaged. 4) Always unplug the power cord before filling, cleaning, servicing, or when the unit is not in use. 5) This humidifier is UL listed with Essick Air brand evaporative wicks in place. To maintain your UL rating, see your service center for all repairs. 6) Regular cleaning is recommended. Refer to the CARE & MAINTENANCE section in the manual. INTRODUCTION Your Essick Air evaporative humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals, or dissolved and suspended solids. Because the water is evaporated, there is just clean and invisible moist air. As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at the beginning of every season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier’s efficiency. Use only Essick Air brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1-800-547-3888. The 400 and 600 Series humidifiers use Essick Air wick # 1041 and air filter #1051. Only the Essick Air evaporative wick guarantees the certified output of your humidifier. Use of wicks other than Essick Air brand will void your warranty as well as the certification of output and may reduce the efficiency of your humidifier. Dry air is drawn into the humidifier through the back and moisturized as it passes through the evaporative wick. It is then fanned out into the room. 1) Water bottles 2) Chassis/Power Pak (motor and fan assembly) 3) Evaporative wick 4) Water channel/tray 5) Dry room air intake 6) Moist air output CAUTION: Do NOT position the unit directly in front of a hot air duct or radiator. Do NOT place on soft carpet. ASSEMBLY, CONTROLS & OPERATION 1) Remove the two polyfoam inserts from the top of the humidifier. 2) Lift off the water bottle cover (left-hand side). Remove the water bottle, lift off the chassis/power pack and then remove the humidifier cabinet from the carton. 3) Remove the evaporative wick, float assembly (black rod with white float), and all of the remaining packaging materials from the cabinet. Check to see that you have all of the following items removed from the boxes accessory kit and cabinet before discarding the packaging: o Filler hose o Caster kit o Bacterial treatment sample o Two water bottles with caps o Evaporative Wick o Cord Set (400 Series only) o Two End Covers o Optional AirCare® filter #1051 (included in 697 and all 400 Series only) May be purchased separately for other 696 model IMPORTANT FILLING INFORMATION 1. Your humidifier is equipped with two water bottles. When both the water bottle and reservoir have emptied, the humidifier fan will automatically shut off, but will start again automatically when the water bottle and reservoir are refilled. 2. When the bottle is being filled for the first time and the wick is still dry, it will take approximately 20 minutes to drain the bottle into the reservoir. After the bottle has emptied, it should be refilled again to obtain maximum running time. 3. When refilling the bottle and the wick is still wet, it will take approximately 12 minutes to refill the reservoir. At this time, you should refill the bottle for maximum running time. CASTERS 4) Turn the emptied cabinet upside down. Insert each caster stem into the four caster holes on each corner of the humidifier bottom. The casters should fit snugly and be inserted until the stem shoulder reaches the cabinet surface. Do not force. 5) Turn the cabinet right side up. EVAPORATIVE WICK 6) The wick has a mounting rib on the top edge which hooks over a rib at the inside back of the cabinet. This allows the wick to hang in the water channel (see illustration). Hang wick into cabinet as shown. AIR CLEANING FILTER (OPTIONAL for 4D7, 427, 447, 697 models) 7) The AirCare filter has four tangs that engage into four keyhole slots that mount the AirCare filter onto the outside of the back of the cabinet. CHASSIS/POWER PACK 8) Place the chassis/power pack unit into the cabinet, so it fits without tipping or rocking. 9) Fill the bottle with cool, fresh (preferably unsoftened) water. If you only have softened water available in your home, you can use it, but you will notice a buildup of minerals on the wick much sooner. The bottle holds 2.75 (400 Series) 2.6 (600 Series) gallons. When filling, be careful not to pressurize it by overfilling. Bottle dama...

Este manual também é adequado para os modelos :
Umidificadores - 447 302 (307.76 kb)
Umidificadores - 697 500 (307.76 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias