Log:
Assessments - 4, GPA: 4.5 ( )

Instruções de Operação Essick Air, Modelo 916 600

Fabricante : Essick Air
Arquivo Tamanho: 683.25 kb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


5/04 Important Safeguards READ BEFORE USING YOUR HUMIDIFIER 1) This appliance has a polarized plug (one blade is wider than the other). To reduce the risk of electric shock, this plug is intended to fit into a polarized 120-volt AC, 15-amp outlet, only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. If an extension cord must be used, it should also accept the wide blade plug and meet this electrical rating. 2) Do not place the cord under rugs, in traffic areas, or near heat sources. 3) Do not use the humidifier if the cord is damaged. 4) Always unplug the power cord before cleaning, servicing or when the unit is not in use. 5) Do not place the humidifier near loose drapes, combustible materials, or heat-producing objects. 6) This humidifier is UL approved with Bemis by Essick Air brand evaporative wicks in place. To maintain your UL rating, see your service center for all repairs. Use only Bemis by Essick Air brand replacement wicks and chemicals. To order parts, wicks and chemicals call 1- 800-547-3888. 7) Regular cleaning is recommended. Refer to CARE & MAINTENANCE section in this manual Introduction Your Bemis by Essick Air evaporative humidifier adds invisible moisture to your home by moving dry inlet air through a saturated wick. As air moves through the wick, the water evaporates into the air, leaving behind any white dust, minerals or dissolved and suspended solids. Because the water is evaporated, there is no messy mist or spray and no white dust, just clean and invisible moist air. As the evaporative wick traps accumulated minerals from the water, its ability to absorb and evaporate water decreases. We recommend changing the wick at least once a year, preferably disposing of the used one at the end of the humidifying season and starting with a new one at the beginning of the next humidifying season. In hard water areas, more frequent replacement may be necessary to maintain your humidifier's efficiency. Care and Maintenance IMPORTANT: We recommend cleaning your humidifier once a week. Follow instructions. Humidifiers provide comfort by adding moisture to dry, heated indoor air. To get the most benefit from the humidifier and avoid product misuse, follow all instructions carefully, specifically the operation, care and maintenance guidelines. Please note this is an electrical appliance and requires careful attention when in use. In addition, if you do not follow the recommended care and maintenance guidelines, microorganisms may be able to grow in the water within the humidifier's reservoir. Caution: Disconnect power before cleaning or servicing unit. 1) Turn unit off. 2) Unplug electrical cord from wall outlet. 3) Lift off motor and fan assembly (top portion of humidifier). REMOVING SCALE 4) Carefully lift wick from cabinet, allowing any water to drain from wick into cabinet. 5) Empty cabinet into sink. Remove any remaining water from cabinet with a sponge. Fill reservoir with one 8 oz cup of undiluted white vinegar. Let solution stay 20 minutes. Clean all interior surfaces with a soft brush. Dampen a soft cloth with undiluted white vinegar and wipe out reservoir to remove scale. 6) Rinse cabinet thoroughly with fresh water to remove scale & cleaning solution before disinfecting. DISINFECTING RESERVOIR 7) Fill reservoir with mixture of one teaspoon chlorine bleach in one gallon water. Let solution stay 20 minutes, swishing every few minutes. Wet all surfaces. 8) Empty reservoir after 20 minutes. Rinse with water until bleach smell is gone. Dry with clean cloth or paper towel. 9) Replace wick in cabinet by sliding the wick into position between locating ribs in sides of cabinet. 10) Replace motor and fan assembly ensuring that it seats correctly on the front and back edge of the cabinet and that the cord is not caught on the edge of the unit. 11) Plug cord into wall outlet. Turn unit on. Summer Storage 1) Clean unit as outlined in Care & Maintenance section. 2) Discard used wick. (install a new Bemis by Essick Air wick at the beginning of the next season. Only Bemis by Essick Air wicks guarantee the output of your humidifier.) 3) Allow unit to dry thoroughly before storage. Do not store with water inside unit. EVAPORATIVE WICK 12) We recommend replacing the wick at least once a season more often in hard water areas. When it appears excessively clogged with mineral deposits, discard it and restore your humidifier's efficiency with a new wick. Bemis by Essick Air evaporative wick number 1044 fits the 900 Series tabletop humidifiers. For replacement wicks call 800-547-3888. Only Bemis by Essick Air evaporative wicks guarantee the out-put o...

Este manual também é adequado para os modelos :
Umidificadores - 926 000 (683.25 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias