Facilidade de uso
9. Reinstall the water panel evaporator assembly into the humidifier. Take care not to over- bend the water level sensor assembly. Push the top of the water panel evaporator assembly firmly back until it snaps into place. 10. Push the end of the feed tube back firmly into the distribution tray. Reset the damper to desired position. Replace the front cover. 11. Turn on the water supply. 12. Check system operation: Humidifier Control: (Automatic or Manual) Check system operation and reset change water panel indicator by setting the knob to “Test/Reset”. With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE. 13. Reset Humidifier Control to its original position. Check operation. MODEL - 11 MODEL 600 MODEL 600 MAINTENANCE INSTRUCTIONS for APRILAIRE HUMIDIFIER MODEL 600 CAUTION! Sudden operation may cause personal injury or property damage. Turn Humidifier Control to “off” or 1. Front Cover 2. Feed Tube 3. Integral Damper 4. Water Panel Evaporator Assembly 5. Distribution Tray 6. “V” Notches 7. Water Panel 8. Scale Control Insert 9. Drain Hose lowest setting before servicing. 1. Note Humidifier Control setting and turn dial to the “OFF” position. 2. Turn off water supply. 3. Press the tabs in the latches on the top and bottom of front cover (1) and pull cover off base with both hands. Set aside. 4. Carefully pull the plastic feed tube (2) out of the distribution tray (5) at the top of the Water Panel evaporator assembly (4). Pull this assembly out by grasping at top and tipping out. 5. Remove the distribution tray (5) from the water panel evaporator assembly by lifting straight up from the scale control insert (8). Lightly scrape out any calcium deposits and clean the “V” notches (6) but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. See page 3 if removed. 6. Slide the Water Panel evaporator (7) out from the Scale Control Insert (8). Clean the insert frame of calcium deposits with a putty knife. Inspect Water Panel evaporator (Stock No. 35 for Model 600) and substitute a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel back into the scale control insert with the colored spot up and snap the distribution tray back into place. 7. Re-install the Water Panel evaporator assembly into the unit by fitting its drain into the round receptacle at the base of the unit. Push the assembly in at the top against the beveled tabs that will hold it in place. Push the end of the feed tube back firmly into the distribution tray and replace the front cover. 8. Remove the drain hose (9) from the bottom of the unit and bend and flex it to loosen the internal calcium deposits. Then flush it with water under pressure and slip it back onto the drain fitting. 9. Turn on the water supply. 10. Check system operation: Humidifier Control: (Automatic or Manual) Check system operation and reset change water panel indicator by setting the knob to “Test/Reset”. With furnace blower operating and furnace calling for heat, humidifier will operate for one minute. DO NOT LEAVE IN TEST MODE AS HUMIDIFIER WILL NOT OPERATE. 11. Set Humidifier Control to its original position. - 12 MAINTENANCE INSTRUCTIONS for APRILAIRE HUMIDIFIER MODEL 700 WARNING! 120 volts may cause serious injury from electrical shock. Disconnect power and shut off water supply before servicing. MODEL 4567813 2 1. Front Cover 2. Base 3. Water Panel Evaporator Assembly 4. Distribution Tray 5. ”V” Notches 6. Water Panel 7. Scale Control Insert 8. Drain Hose 9. Power Cord 9 1. Note Humidifier Control setting and turn dial to the “OFF” position. 2. Disconnect electrical power and turn off water supply. 3. Unlatch humidifier cover assembly (1) from base assembly (2) at the bottom of the cover, lift, and set aside. 4. Pull out the water panel evaporator assembly (3) by grasping at the top and tipping out. 5. Remove the distribution tray (4) from the water panel evaporator assembly (3) by unsnapping the plastic holding strips from the tabs at the end of the tray. Lightly scrape out any calcium deposits and clean the “V” notches (5) but do not scrape off the granular coating from the bottom. This textured surface helps ensure even water flow for maximum performance. 6. Slide the Water Panel evaporator (6) out from the Scale Control Insert (7). Clean the Scale Control Insert by twisting and flexing it to loosen the calcium deposits or use a putty knife. Inspect the Water Panel evaporator (Stock No. 35) and replace with a new Genuine Aprilaire Water Panel if necessary. Slide the Water Panel evaporator back into the scale control insert with the colored spot up and snap the distribution tray (4) back into place. 7. Re-install the water panel evaporator assembly (3) into the base assembly (2). Push it in at the top between the retaining ribs that hold the assembly in place in a vertical pos...
Este manual também é adequado para os modelos :Umidificadores - 550 (90.85 kb)
Umidificadores - 600 (90.85 kb)