|
Facilidade de uso
If after the installation of your unit, the circuit breaker trips or the fuse fails on a repeated basis, then a dedicated circuit will likely be required.Any new wiring must be done in compliance with local and national codes and other applicable regulations in order to reduce the risk of fire, electric shock or other injuries. Therefore, it is strongly recommended that you hire a licensed electrician to complete any such work. 117191-01A GROUNDING INSTRUCTIONS This stove is for use on 120 volts. The cord has a plug as shown in Figure 2. An adapter is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available. To decrease the desired temperature, turn the temperature dial counter clockwise towards number 1. The heater has a built-in thermostat so it will shut off automatically once the settemperature is reached. It will also turn on automatically if the room temperature drops below the set temperature on the dial. Note: When the heater is turned on for the first time, it may release a slight, harmless odor.Thisodoris a normal occurrence caused by the initial heating of the internal heating Figure 2 - Grounding Methods Figure 3 - Electric Stove Control Panel OPERATING INSTRUCTIONS Once the unit has been properly connected to a ground electrical outlet, it is ready to operate. Note: Ensure the circuit breakers for power supply are turned on. CONTROL PANEL OPERATION Controls are located on the back of the unit (see Figure 3). 1. Main ON/OFF power switch: This switch is located at the furthest right corner on the control panel when looking at the back of the unit. Turn the switch to ON and unit will be ready to operate. The "|" indicates ON and "O" indicates OFF. 2. Heater Switch and Control Dial: The heater switch has a sun directly below it. To turn the heater on, flip the Heater Switch to ON position (the "|" indicates ON and "O" indicates OFF). The Control Knob has a thermometer below it. Turn the dial clockwise past the number 8. You should elements and should not occur again. 4. Flame Control Dial: This dial controls the intensity of the flame. Light Adjustment Dial Main Power SwitchFlame Control Dial Heater SwitchHeat Control Dial Grounding Pin Adapter CLEANING AND MAINTENANCE WARNING: Always discon- nect power and allow the heater to cool before performing any cleaning,maintenanceorreloca- tion of this heater. Turn controls to OFF and remove plug from outlet or turn off circuit breaker to heater. Turn off heater and circuit breaker to heater before performing any cleaning and/or maintenance. Al- low heater to cool completely. BULB REPLACEMENT hear a small clicking sound indicating the heater has started and heat will emit the from the vents at the top of the unit. To turn off heater, turn the temperature dial counter clockwise past number 1 and flip the Heater Switch to OFF position. To increase the desired temperature, turn the temperature dial clockwise towards Number 8. WARNING: The halogen light bulbs in your unit can become extremely hot. Allow at least 10 minutes between turning off the heater and removing the light bulbs to avoid accidental burns. 117191-01A CLEANING AND MAINTENANCE Continued There are a total of 7 halogen light bulbs (type GX6.35 rated 120 volts, 35 watts) in your unit. • 2 bulbs provide illumination for the ember bed beneath the log set • 2 bulbs provide illumination for the flame generation assembly • 1 bulb provides illumination for the top contrasting light • 2...
Este manual também é adequado para os modelos :Hobs - CGESBM (375.22 kb)
Hobs - CGESBM (375.22 kb)
Hobs - CGESBM (375.22 kb)
Hobs - CGESBM (375.22 kb)