Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação FCI Home Appliances, Modelo ECCB 30"

Fabricante : FCI Home Appliances
Arquivo Tamanho: 2.41 mb
Arquivo Nome : FCI_Cooktop_manual.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


Make sure the front edge of the counter top is parallel to the cooktop. Make final check that all required clearances are met. Figure 9. Step 6 Loosen the screws, rotate the brackets so that they extend beyond edge of the burner box. Tighten screws securely. Figure 10. Installation Manual Models ECCB/TCCB 30” – 36” ENGLISH Figure 11. Figure 12. WARNING THE CONDUIT IS 3 FEET LONG The junction box, must be located where it will allow considerable slack in the conduit for serviceability. Models ECCB/TCCB 30” – 36” ENGLISH Figure 11. Figure 12. WARNING THE CONDUIT IS 3 FEET LONG The junction box, must be located where it will allow considerable slack in the conduit for serviceability. Important: • For solid surface material installations such as Surel™ and Corian®, consult with solid surface manufacturer. Apply heat reflective tape such as Scotch® Aluminum Foil Tape #425 or #427 around the cutout so that it folds over on the top and sides. • Do not wrap the tape underneath the cooktop. Be sure the tape extends beyond the outermost flange of the cooktop. All corners should be covered with tape. Installation Manual Models ECCB/TCCB 30” – 36” ENGLISH Electrical Connections DANGER Disconnect power before servicing the product. Failure to do so could result in death or electrical shock. General information This cooktop does not require a neutral connection. If the cooktop is to be completely enclosed in a cabinet, feed the cooktop cable through the opening in the cabinet. Make the electrical connection following the appropriate steps for your installation. Your cooktop must be connected to the proper electrical voltage and frequency as specified in the table on the right. Figure 13. Location of serial tag Connect with copper wire only If the house has aluminum wiring, follow the procedure below: 1. Connect the aluminum wiring to the copper wire by using special connectors designed and Underwriters Laboratories-listed for joining copper to aluminum. Follow the electrical connector manufacturer's recommended procedure. 2. Aluminum/copper connection must conform with local codes and industry- accepted wiring practices. The flexible conduit (supplied) 3 feet long (100 cm) located at the right rear of the cooktop bottom box should be connected directly to junction box. Do not cut the conduit. A U.L - or CSA - listed conduit connector must be provided at each end of the power supply cable (at the cooktop and at the junction box.) A time delay fuse or circuit breaker is recommended. Do not ground to a gas pipe. Do not have a fuse in the grounding or neutral circuit. Fuse both supply (phase) lines. WARNING Improper connection of aluminum house wiring to the copper leads can result in a serious problem. Minimum supply wire size No. 10AWG No. 10AWG No. 10AWG *Digits identifying color cooktop National Fire Protection Association Batter/march Park Quincy, Massachusetts 02269 A three-wire, single phase, 240 volt 60 cycle electrical system (properly circuit protected to meet Local Codes of NFPA No.70) must be provided. Unit must be properly grounded in accordance with local wiring code. The chart below recommends the minimum circuit protector and wire size if the appliance is the only unit on the circuit. If smaller sizes of wire are used, the unit efficiency will be reduced and a fire hazard may be created. It is advisable that the electrical wiring and hookup be accomplished by a competent electrician. Installation Manual Models ECCB/TCCB 30” – 36” ENGLISH Recommended Minimum Wire size (AWG) 12 -10 8 -8 -6 Be sure your appliance is properly installed and grounded by a qualified technician. Ask your dealer to recommend a qualified technician or an authorized repair service. This cooktop does not require a neutral connection. If the cooktop Is to be completely enclosed In a cabinet, feed the cooktop cable through the opening in the cabinet. Make the electrical connection following the appropriate steps for your installation. This appliance is manufactured with a green ground wire connected to the cooktop chassis. After making sure that the power has been turned off, connect the flexible conduit from the cooktop to the junction box using a U.L. listed conduit connector. Figures 14 and 15 and the instructions provided below present the most common way of connecting the cooktops. Your local codes and ordinances, of course, take precedence over these instructions. Complete electrical connections according to local codes and ordinances DANGER Risk of Electric Shock, frame grounded to neutral of appliance through a link. Grounding through the neutral conductor is prohibited for new branch-circuit installations (1996 NEC); mobile homes; and recreational vehicles, or in an area where local codes prohibit grounding through the neutral conductor. 3-Wire branch circuit Where local codes allow the connection of ground wire from the cooktop to the branch circuit neutral wire (gray or white colored wire) proceed as follows (see figure 14). 1. ...

Este manual também é adequado para os modelos :
Hobs - ECCB 30" (2.41 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias