Changing the Orifice figure 1 CG901M only CG901M only (size numbers are stamped on the side, eg. 70= 0.70mm) (see figure 1). 8 Reset the venturi position aligning the end of the venturi tube with the edge of the slot in the bracket below it. Outermost position for LPG, innermost for NG (see figure 2). Some fine adjustment may be required for local conditions. 9 To replace the CG901M hob, repeat steps 3-6 in reverse. 10 Reset the minimum setting. See ‘Minimum Setting’ overleaf. The label supplied with the orifices should be placed over the existing gas type label to indicate the change. Venturi Position figure 2 NG Venturi Position LPG Venturi Position INSTALLATION INSTRUCTIONS US LEAK TESTING Leak testing of the appliance shall be conducted according to the manufacturer's instructions. The appliance and it's individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system in excess of 1/2 p.s.i. (3.5kPa). The appliance must be isolated from the gas supply piping system by closing it's individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures at or less than 1/2 p.s.i.(3.5kPa). Maximum inlet gas supply pressure 4" W.C. Natural Gas, 11" W.C. LP gas. Minimum gas supply pressure for regulator testing 5" W.C. Natural Gas, 12" W.C. LP gas. After installing the gas supply and making all connections check thoroughly for possible leaks. 1 Turn all control knobs on unit to "off" position. 2 Open the valve on the gas supply. 3 Using a leak detection fluid (e.g. Rocol leak detection spray) check each gas connection one at a time by brushing the solution over the connection. The presence of bubbles will indicate a leak. 4 If necessary, tighten the fitting and recheck for leaks. 5 Turn on burner valve and light each burner. 6 Check for a clear blue flame without yellow tipping. If burners show any abnormalities, check that they are located properly and in line with the injector orifice. MINIMUM SETTING OR TURNDOWN This has been set at the factory for NG but can be checked after the correct pressure has been reached. To adjust for minimum setting (if applicable), you will need a O 7/64 " x 1 3/4" (O2.5 x 45mm) screwdriver. (A suitable screwdriver is available as Fisher & Paykel spare part. FB200467). 1 Ignite the burner and set the knob to its minimum position. 2 Remove the knobs. 3 Rotate the turn down screw (down the hole in the spindle) while holding the shaft. Rotate slowly until a minimum regular flame is achieved. (The flame will diminish when the screw is turned clockwise and increase when turned counter clockwise). 4 When the setting is right check regulation by quickly rotating the knob from the maximum to the minimum delivery position. The flame must not go out and the autoreignition should not click. Replace the knob. Minimum setting adjustment (Note: this diagram is of GC901 but is similar for GC36). See the Product Installation Checklist attached to the product. INSTALLATION INSTRUCTIONS CHECKING THE GAS TYPE GC36 US Burners NG Orifice (mm) NG BTU (MJ/h)@ 0.15psi (4”H20) LP Orifice (mm) LP BTU (MJ/h)@ 0.41psi (11”H20) RH Rear LH Rear RH Front Simmer LH Front Wok Center 1.3mm 1.3mm 0.85mm 1.75mm 1.45mm 8,000 (8.4 MJ/h) 8,000 (8.4 MJ/h) 3,500 (3.47 MJ/h) 12,600 (13.3 MJ/h) 9,500 (10 MJ/h) 0.8mm 0.8mm 0.55mm 1.05mm 0.85mm 8,000 (8.4 MJ/h) 8,000 (8.4 MJ/h) 4,000 (4.2 MJ/h) 13,000 (13.7 MJ/h) 9,500 (10.0 MJ/h) GC901 / GC901M Burners NG Orifice (mm) NG BTU (MJ/h)@ 0.15psi (4”H20) LP Orifice (mm) LP BTU (MJ/h)@ 0.41psi (11”H20) RH Rear LH Rear RH Front Simmer LH Front Center (GC901) Center (GC901M) 1.3mm 1.1mm 0.85mm 1.3mm 1.75mm 2.15mm 8,000 (8.4 MJ/h) 5,800 (6.1 MJ/h) 3,000 (3.2 MJ/h) 8,000 (8.4 MJ/h) 14,000 (14.8 MJ/h) 20,000 (21.1 MJ/h) 0.8mm 0.7mm 0.55mm 0.8mm 1.05mm 1.22mm 8,200 (8.7 MJ/h) 5,700 (6.0 MJ/h) 3,500 (3.7 MJ/h) 8,200 (8.7 MJ/h) 13,000 (13.7 MJ/h) 19,000 (20 MJ/h) CONTACT DETAILS A Service Summary is attached to the underside of the product. For replacement parts or if further help is needed concerning this appliance call: Toll Free 1 888 9 FNP USA (1 888 936 7872) or write to: Fisher & Paykel Appliances Inc. 27 Hubble, Irvine CA 92618 or contact us through our web site, AVERTISSEMENTS ET INFORMATIONS SUR LA SECURITE FR AVERTISSEMENT ! Cet appareil devra etre installe en conformite avec les exigences d’installation de la compagnie du gaz locale ou avec le code d’installation applicable ou en l’absence de codes locaux avec le code national reglementant le gaz et le fioul ANSI Z223.1 ou CAN B149.1.2 (Canada) le plus recent. Les codes locaux reglementant l’electricite et la construction devront etre respectes. Une fois cet appareil installe, il ne devra pas etre utilise comme appareil de chauffage. Aucun materiau ou produit combustible ne devra etre place sur cet appareil a tout moment. Ne pas vaporiser de bombes aerosols a proximite de cet appareil pendant qu’il est en...
Este manual também é adequado para os modelos :Hobs - GC901 (1.17 mb)