Log:
Assessments - 3, GPA: 3.3 ( )

Instruções de Operação Bertazzoni, Modelo Z36600X

Fabricante : Bertazzoni
Arquivo Tamanho: 1.89 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be installed in conformity with the national standards in force. 2 INSTALLATION MANUAL BACKGUARD INSTALLATION INSTRUCTION Please follow the following installation instructions afther installing the cooktop: 1) Remove n°2 screws fixing worktop as shown in fig.1 2) Place front part of the backguard and attach it from bottom side with the two removed screws (point 2) as shown in fig .2 3) Fix the front part of the backguard with the screws supplied with the backguard kit (fig.3) 4) Assemble back part with front part of backguard and fix them with a screw supplied with the backguard kit (fig.4) 1 2 3 4 WORKTOP FRONTGUARD INSTALLATION INSTRUCTIONS In order to increase the clearance between front edge of the worktop and the burners for your safety it is recomended to install the worktop frontguard supplied with the appliance. For installation instructions follow the instructions indicated in the following figures 3 PROXIMITY TO SIDE CABINET INSTALLATION 1. This rangetop may be installed directly adjacent to existing 36" (91.5 cm) high base cabinets. IMPORTANT: The top grate support MUST be 3/8" (.95 cm) above the adjacent base cabinet countertOP. 2.The rangetop CANNOT be installed directly adjacent to sidewalls, tall cabinets, tall appliances, or other side vertical surfaces above 36" (91.5 cm) high. There must be a minimum of 6" (15.2 cm) side clearance from the rangetop to such combustible surfaces above the 36" (91.5 cm) counter height. 3.3. Within the 6" (15.2 cm) side clearance to combustible vertical surfaces above 36" (91.4 cm) I the maximum wall cabinet depth must be 13" (33.0 cm) and wall cabinets within this 6" (15.2 cm) side clearance must be 18" (45.7 cm) above the 36" (91.4 cm) high countertop. 4.4. Wall cabinets above .the rangetop must be a minimum of 36" (91.4 cm) for the open top burner models and a minimum of 42" (106.7 cm) for the sealed burner models above the rangetop cooking surface for the full width of the rangetop. This minimum height requirement does nQ1 apply if a rangehood is installed over the cooking surface. A 6”(15.2cm) MIN B 36”(91.5cm) C 36”(91.5cm) D 13”(33.0cm)MAX E 18”(45.7cm)MIN F 36”(91.5cm) G 6”1/2(16.5cm) H 1”(2.5cm) MIN i 9/16” (1.8cm) L 2”( 5 cm) MIN 120 VAC/60 Hz withing 48” (122.9cm) of right rear or rangetop 4 COOKER HOOD INSTALLATION The bottom of the hood should be 25 . " (65 cm) min. to 31 . " (80 cm) above the countertop. Refer to the rangehood installation instructions for additional information. These dimensions provide for safe and efficient operation of the hood. ELECTRICAL CONNECTION This unit is manufactured for a polarized, grounded 120 volt/60 Hz, 16 amp system. Electric power consumption is about 1 W. The minimum of 102 VAC is required for proper operation of gas ignition systems. This circuit must be grounded and properly polarized. The unit is equipped witth a SJT power cord, and in case of replacement, the cable shall be replaced with one of the same type, size and length. WARNING Electrical Grounding Instructions This appliance is equipped with a three prong plug for your protection against shock hazard and should be plugged directly into a properly grounded socket. Do not cut or remove the grounding prong from this plug. WARNING ELECTRICAL SHOCK HAZARD • Disconnect electrical power at the circuit breaker box or fuse before installing the appliance • Electrically ground appliance • Use copper conductors only. Failure to follow these instructions could result in seriuos injury or death 5 Wiring diagram For freestanding gas range model C36600X (Z36 6 00 X) C3Y0..U4X(2 or 5)A CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. For freestanding gas range model C36500X (Z36 5 00 X) C3W0..U4X(2 or 5)A CAUTION: label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. 6 GAS CONNECTION All gas connections must be made according to national and local codes. This gas supply (service) line must be the same size or greater than the inlet line of the appliance. This range uses a 1/2" NPT (see fig. in this chapter for details of gas connections installations) inlet. Sealant on ali pipe joints must be resistive to LP gas. 1. Manual Shut-off Valve: This installer-supplied valve must be installed in the gas service line ahead of the appliance in the gas stream and in a position where it can be reached quickly in the event of an emergency. The manual shut-off valve shall be installed properly in order to be accessible when appliance is installed in definitive position. In Massachusetts: A 'T' handle type manual gas valve must be installed in the gas supply line to this appliance. 2. Pressure Regulator (see fig. in this chapter) a) All cooking equipment must ...

Este manual também é adequado para os modelos :
Hobs - C36500X (1.89 mb)
Hobs - C36600X (1.89 mb)
Hobs - Z36500X (1.89 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias