Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Dacor, Modelo 35610C

Fabricante : Dacor
Arquivo Tamanho: 177.42 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


IGNITION HT SPARK Spark Generator Ispra Control's BF 50046 - 230-240V 0.6 YA T120 Spark Gap : Fixed HEAT INPUT Rear Left Burner 2.0 kW (6824 BTU/HR) (semi rapid) Front Left Burner 3.0 kW Natural Gas (10236 BTU/HR) (rapid) 2.8 kW L.P.G. (9554 BTU/HR) Rear Right Burner 2.0 kW (6824 BTU/HR) (semi rapid) Front Right Burner 1.0 kW (3412 BTU/HR) (auxiliary) APPLIANCE CLASS 3 APPLIANCE CATEGORY II2H3+ GAS SUPPLY Natural gas G20 / 20mbar BURNER RAPID SEMI-RAPID AUXILIARY (large) (medium) (small) TYPE OF GAS POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 3.0 0.65 2.0 0.45 1.0 0.33 NATURAL GAS 20 mbar NOMINAL FLOW VALUE = RATE m3/h 0.286 0.057 0.190 0.038 0.095 0.028 37.78 MJ/m3 NOZZLE REFERENCE 119 Adjust. 96 Adjust. 70 Adjust. Ws - 50.7 MJ/ m3 1/100 mm NOMINAL THERMAL LPG GAS POWER kW 2.8 0.65 2.0 0.45 1.0 0.33 28-30/37 mbar NOMINAL FLOW VALUE = RATE g/h 202 43.5 144 29 72 21,5 49.92 MJ/Kg NOZZLE REFERENCE 86 40 71 32 50 28 1/100 mm Burner Dia. Tap By-pass Tap colour 1/100 mm Auxiliary 28 Red/Red Semi-rapid 32 Blue/Blue Rapid 40 Black/Black Aeration adjustment none Important safety requirements This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition). Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions. The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air vent is required. However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3. If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements. Location The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room. Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm. between the rear edge of the hob and the wall. A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls. The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 400 mm. If it is fitted below 400 mm. a space of 50 mm. must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm. CLEARANCES REQUIRED CLEARANCES REQUIRED WHEN FITTING THE GAS HOB WHEN FITTING THE GAS HOB WITHOUT A COOKER HOOD ABOVE WITH A COOKER HOOD ABOVE 400 mm 400 mm 100 mm 50 mm 50 mm 55 mm 600 mm FO 0813 700 mm 700 mm 400 mm 400 mm F...

Este manual também é adequado para os modelos :
Hobs - 34602G (177.42 kb)
Hobs - 34611C (177.42 kb)
Hobs - 34611C (177.42 kb)
Hobs - 35604G (177.42 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias