Log:
Assessments - 0, GPA: 0 ( )

Instruções de Operação Bosch, Modelo PPH626B90A/01

Fabricante : Bosch
Arquivo Tamanho: 1.33 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


WARNING: Ensure that the hose assembly is restrained from accidental contact with the flue outlet of an under- bench oven. Before Leaving- Check all connections for gas leaks with soapand water. DO NOT use a naked flame for detecting leaks. Ignite all burners both individually and concurrently toensure correct operation of gas valves, burners and ignition. Turn gas taps to low flame position and observe stability ofthe flame for each burner individually and all together. Adherethe duplicate data plate to an accessible location near thehotplate. When satisfied with the hotplate, please instruct the user on thecorrect method of operation. In case the appliance fails to operate correctly after all checks have been carried out, refer to the authorised service providerin your area. It should be expressly noted that we cannot accept anyliability for direct or indirect damage caused by wrongconnection, leakage or improper installation. When beingrepaired, the appliance must always be disconnected from the mains supply; if required, notify our customer service. Coverting the cooktop from Nat.Gas to Universal LPG To change injectors All work involved in installation, setting and adaptation to a different gas type must be carried out by authorised personnel from our Service Centre and must comply with current regulations and the conditions laid down by the local gas company. Request change-over injectors from our customer service deparment (refer injector chart below for sizes). Natural Gas Universal LPG Burner Hourly Gas (MJ) Consumption Injector mark Hourly Gas (MJ) Consumption Injector mark Small 4,0 90 3,25 50 Medium 6,5 118 6,25 67 Large 12,0 1 60 10,0 85 wok (Center) 13,0 170 13,25 97 wok (Left front) 13,0 170 10,8 94 Before conversion the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position. 1 Remove the trivets, burner caps and burner heads. Refer Fig. 7. 2 Change the injectors using a 7-mm socket wrench and be sure to tighten them down properly so that they are fully airtight. Refer Fig. 8. 3 Re-assemble the burner component parts in reverse order. NOTE: it is not necessary to adjust the primary air control on these burners. 7 mm 87 Minimum flame adjustment. 1 Turn the control knob to minimum. 2 Remove the control knob from the valve spindle. Refer Fig. 9. 3 Apply pressure with the tip of the screwdriver to release the thread toward the tap's adjusting screw. Refer Fig.10. 4 The adjustment screw is positioned at the rear lower section of the valve. 5 To adjust the minimum flame for N.G. replace the control knob onto the spindle, light the gas and turn the control knob to the small flame position. Screw the adjustment screw anti-clockwise to estabilish a minimum stable flame position. The flame should remain alight and not burn back to the injector when the valve is turned quickcly from ‘Full On’ to the “Minimum flame” position and back a few times. To adjust the minimum flame position for ULPG the screw must be fully tightened down clockwise. 6 Refit the control knob. Never dismount the valve shaft: in the event of damage, change the entire valve. 9 10 Operating instructions Burner locations 1 5 3 4 6 6 1 2 5 4 3 1211 1. Medium burner 4. Small burner 2. Medium burner 5. Rapid burner 3. Wok burner 6. Control Knobs Depress control knob and turn anti-clockwise to “High Burner ignition & flame”position. Hold the knob down for a few seconds control until the flame ignites. Keep control knob depressed for a few seconds to activate the flame failure device. If ignition fails, depress knob again and wait for ignition. Turn anti-clockwise to set the flame to the desired intensity. If ignition fails depress knob and try again. If flame is not established in 15 seconds release the control knob and open a door and wait 1 minute beforeattempting a new ignition procedure. All burners are fitted with a flame failure device which shuts off the gas supply if the flame extinguishes for any reason. To re-ignite, wait 30 seconds for any unburnt gas to disperse before repeating the ignition procedure described above. To turn off the gas supply to a burner turn the control knob clockwise to the “OFF” position. (Refer Fig. 1 2 ) 12 Burner Position Graphic The control knob is used to adjust the flame of the gas burner. “Low flame” graphic= lowest output “High flame” graphic= higest output If the ignition sparkers are dirty, this makes the burners harder to light, so you should keep them as clean as possible. Clean them using a small brush andremember that the ignition sparkers must be treatedvery gently. User Instructions . Boiling burners . Use “High flame” setting to bring the pan to the boil, then adjust the flame between “High flame” and “Low flame” to maintain the required pan temperature. Important: The use of a cooktop leads to the production of heat and moisture in the kitchen .For this reason make sure that the room is properly ventilated.Keep natural ventilation ........... ....

Este manual também é adequado para os modelos :
Hobs - PPQ726B90A/01 (1.33 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias