Log:
Assessments - 2, GPA: 3 ( )

Instruções de Operação Jenn-Air, Modelo CGESBL

Fabricante : Jenn-Air
Arquivo Tamanho: 456.26 kb
Arquivo Nome : c615bf8d-1294-3e74-692c-454816664644.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Prior to permanently installing the unit, test to make sure the unit operates properly by plugging the power supply cord into a conveniently located 120-volt grounded outlet. CAUTION: The unit's power supply cord must be connected to a properly grounded and pro- tected 120-volt outlet. Always use ground fault protection where required by the electri- cal code. WARNING: Do not operate the unit if it is damaged or has malfunctioned.Ifyoususpectthe unit is damaged, return the unit to an authorized service facility for examination, electrical or me- chanical adjustment or repair. Frequency 60 Hz Heater Power 1500 W Heater Output 5000 BTUs Power Supply 120V; 15 Amp Grounded, Circuit Figure 1 - Heater Dimensions Note: A dedicated power supply circuit is recom- mended for the unit but not required. Additional electrical appliances on the same circuit may ex- ceed the current (amperage) rating for that circuit. If after the installation of your unit, the circuit breaker trips or the fuse fails on a repeated basis, then a dedicated circuit will likely be required. Any new wiring must be done in compliance with local 27" 15" 26" 12.5" 25.25" 18" CGESBMR Remote Controlled 18" Electric Stove CGESBL Remote Controlled 27" Electric Stove and national codes and other applicable regulations in order to reduce the risk of fire, electric shock or other injuries. Therefore, it is strongly recommended that you hire a licensed electrician to complete any such work. 117190-01A GROUNDING INSTRUCTIONS This stove is for use on 120 volts. The cord has a plug as shown in Figure 2. An adapter is available for connecting three-blade grounding-type plugs to two-slot receptacles. The green grounding lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. The adapter should not be used if a three-slot grounded receptacle is available. Grounding Pin Adapter Figure 2 - Grounding Methods 2. Display ON/OFF Dial: There is a flame icon directly below this dial and it is the knob at. After you turn the Main Power switch to the ON position, turn the Display Dial to desired setting. Both the logset and the flame will light up inside the fireplace OPERATING INSTRUCTIONS Once the unit has been properly connected to a ground electrical outlet, it is ready to operate. Note: Ensure the circuit breakers for power supply are turned on. CONTROL PANEL OPERATION Controls are located on the back of the unit (see Figure 3). 1. Main ON/OFF power switch: This switch is located at the furthest right corner on the control panel when looking at the back of the unit. Turn the switch to ON and unit will be ready to operate. The "|" indicates ON and "O" indicates OFF. IMPORTANT: Once you turn the main switch to the ON posi- tion, the remote control can no longer be used. In order to use the remote control, you must keep the main ON/OFF switch in the OFF. Display Dial Main Power SwitchFlame Control Dial Heater Switch Heat Control Dial 3. Heater Switch and Control Dial: The heater switch has a sun directly below it. To turn the heateron,fliptheHeaterSwitchtoONposition (the"|"indicatesONand"O"indicatesOFF). The Control Knob has a thermometer below it. Turn the dial clockwise past the number 8. Youshouldhearasmallclickingsoundindicating the heater has started and heat will emit throughventslocatedatthebottomoftheunit. To turn off heater, turn the temperature dial counter clockwise past number 1 and flip the Heater Switch to OFFposition. Heat will stop coming out of the vent. To increase the desired temperature, turn the temperature dial clockwise towards Number 8. To decrease the desired temperature, turn the temperature dial counter clockwise towards number 1. The heater has a built-in thermostat so it will shut off automatically once the settemperature is reached. It will also turn on automatically if the room temperature drops below the set temperature on the dial. Note: When the heater is turned on for the first time, it may release a slight, harmless odor.Thisodoris a normal occurrence caused by the initial heating of the internal heating elements and should not occur again. 4. Flame Control Dial: This dial controls the intensity of the flame. Figure 3 - Electric Stove Control Panel OPERATING BY REMOTE CONTROL 1. Plug in your electric fireplace and it will beep once. This means you have power and your remote is ready to operate your electric fireplace. IMPORTANT: To control the electric fireplace by remote, the Main ON/OFF power switch on the fireplace must be in the OFF position; the remote control will NOT work if the manual ON/OFF switch is in the ON position. 117190-01A OPERATING INSTRUCTIONS Continued 2. When operating the rem...

Este manual também é adequado para os modelos :
Hobs - CGESBL (456.26 kb)
Hobs - CGESBL (456.26 kb)
Hobs - CGESBL (456.26 kb)
Hobs - CGESBL (456.26 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias