Fabricante : Faber
Arquivo Tamanho: 416.59 kb
Arquivo Nome : fdbd121f-8b29-49bb-93bc-9758c11ca9cb.pdf
|
Facilidade de uso
For best performance, use no more than three 90° elbows. To calculate the length of system you need, add the equivalent feet (meters) for each vent piece used in the system. See the following example. 90° elbow 6 ft. (1.8 m) 3 ft. (0.93 m) 3-1/4" x 10" (8.3 cm x 25 cm) vent system 3-1/4" x 10” wall (8.3 cm x 25 cm) cap Maximum length = 26 ft. (8 m) 1 — 90° elbow = 5 ft. (1.5 m) 9 ft. (2.8 m) straight = 9 ft. (2.8 m) 1 — wall cap = 0 ft. (0 m) Length of 3-1/4" x 10" (8.3 cm x 25 cm) system = 14 ft. (4.3 m) Recommended standard fittings 3-1/4" x 10" (8.3 cm x 25 cm) 90° elbow = 5 ft. (1.5 m) 3-1/4" x 10" (8.3 cm x 25 cm) flat elbow = 12 ft. (3.7 m) 3-1/4" x 10" (8.3 cm x 25 cm) wall cap = 0 ft. (0 m) Product dimensions Note: Underside of hood must be a minimum of 24" (61 cm) from cooking surface. 7-3/4" (19.6 cm) 9-15/16" (25.2 cm)3-3/16" (8.1 cm) 2-11/32" (6.0 cm) 1-3/4" (4.4 cm) Do not use these knockouts 1-13/16" (4.6 cm) 2-9/16" (6.5 cm) 1-9/16" (4.0 cm) 1-3/16" (3.0 cm) 1-3/16" (3.0 cm) 4-3/4" (12.1 cm) 5-1/16" (12.9 cm) 9-27/32" (25.0 cm) 17-3/4" (45.1 cm) 13-3/8" (34.0 cm) 30" (76.2 cm) 36" (91.4 cm) Roof-vented model shown. Now start... 1.Put a thick protective covering over cooktop, set-in range or countertop to protect from damage or dirt. If installing over a freestanding range, disconnect and move the range to provide easier access to the upper cabinet and rear wall. Slide range onto cardboard or hardboard before moving to prevent damaging floor covering. 2.Place hood on a protective cover with filters facing down. 3.Determine which venting method (roof, wall or non-vented) will be used. •The hood is factory-set for roof venting. • For non-vented installations, go to Step 4. vent connection seal plate top knockout If venting through the wall, remove seal plate from back of hood and vent connector from top of hood. Reinstall vent connector onback of hood and seal plate on top of hood. 4.Remove knockout from the wiring opening (top or back) to be used. back knockout do not use these knockouts centerlines 5.Mark centerlines on rear wall and upper cabinet bottom. For non-vented installations: Extend centerline up onto soffit above hood. template 6.Align centerlines of template with centerlines marked on rear wall and upper cabinet bottom. Tape template in place. Mark location of the four holes used to secure hood to upper cabinet. 7.Depending on your installation, mark location of the wiring hole or vent cutout in upper cabinet or back wall needed as shown on template. 8.Remove template. 9.Drill four 3/16" (5.0 mm) diameter holes through upper cabinet for the hood mounting screws. 10.Drill the 1-1/2" (4.0 cm) wiring hole. 11.Make the vent cutout for 3-1/4" x 10" (8.3 x 25.4 cm) rectangular vent system. Note: It is recommended that vent system be installed before installing hood. 12.Turn the hood over so filters face up. 13.Rotate deflector away from filters. Pull grease filter handles toward back of hood to release locking tabs. Lift filters up, remove from hood and set aside. screw locations screw 14.Remove 2 screws from light panel tabs. On light panel surface directly behind tabs, push toward back of the hood to move tabs out through the slots. Remove panel and set aside with screws. remove screws wiring box cover 15.Remove 2 screws from wiring box cover located in the right hand rear corner and remove cover. Attach the U.L.- or CSA- listed strain relief to the hood wiring hole being used. 16.Turn hood over so filters face down. .Attach hood damper into vent connector. Make sure that damper swings freely. If wall or roof vent system cap has a damper, DO NOT atta...
Este manual também é adequado para os modelos :Fans - KHTU160 (416.59 kb)
Fans - KHTU160 (416.59 kb)
Fans - KHTU160 (416.59 kb)
Fans - KHTU160 (416.59 kb)