Log:
Assessments - 4, GPA: 3.8 ( )

Instruções de Operação Wells, Modelo WVSW VENTLESS HOOD

Fabricante : Wells
Arquivo Tamanho: 399.03 kb
Arquivo Nome : 6b0348d6-b483-43b9-93fd-82402a4a4cb3.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


531 p/n 305812 OpManual for Conveyor Hood 6 OPERATING CONTROLS Controls include a lighted POWER SWITCH and an amber REPLACE FILTER indicator light. Press POWER SWITCH to ON anytime conveyor warmer is operating. When power is first turned on, the REPLACE FILTER light will glow. As the fan comes up to speed and air flow is established, the REPLACE FILTER light will go out. If the REPLACE FILTER light does not go out, the filters must be replaced. However, the fan will continue to operate when the REPLACE FILTER light is lit. FILTER REMOVAL AND INSTALLATION Disconnect power from hood and conveyor warmer before servicing filters. Remove screw from filter access panel on front (operator's) side of hood. Slide filter pack (high efficiency filter and charcoal filter) from filter chamber. Slide new filter pack into filter chamber. Be sure airflow markings on both filters point "up". Close access panel and reinstall screw. IMPORTANT: Filters are disposable. Never attempt to wash either filter. Filters will absorb water if washed, causing food contamination and possible equipment damage. Fig. 4 Operating Controls CAUTION! RISK OF INJURY Disconnect power from hood and conveyor warmer before servicing filters. IMPORTANT: DO NOT store anything on top of the hood. DO NOT block the exhaust opening. IMPORTANT: Both the high efficiency and charcoal filters must be in place at all times during operation. OPERATION 531 p/n 305812 OpManual for Conveyor Hood OPERATION 531 p/n 305812 OpManual for Conveyor Hood Fig. 5 Filter Installation 7 PREPARATION Unplug hood and conveyor warmer Allow to cool completely before cleaning FREQUENCY Daily TOOLS Mild Detergent Soft Cloth or Sponge 1. Disconnect power from hood and conveyor warmer before cleaning. 2. Remove entry and exit canopies. Canopies may be washed in a sink or dishwasher. Rinse and dry canopies thoroughly. 3. Wipe interior and exterior surfaces of hood with a soft cloth or sponge dampened with water and a mild detergent. IMPORTANT: Never attempt to wash either filter. Filters will absorb water if washed, causing food contamination and possible equipment damage. 4. Rinse all washed areas by wiping with a clean soft cloth dampened with clean water. Dry with a soft cloth. 5. Reinstall entry and exit canopies. Procedure is complete CAUTION! RISK OF INJURY Disconnect power from hood and conveyor warmer before cleaning. IMPORTANT: DO NOT spill or pour water into controls, control panel or wiring. DO NOT spill or pour water into exhaust opening. DO NOT submerge hood in water or wash with water or steam spray. Damage to internal components will occur. Damage to internal components from water damage is not covered by warranty. CLEANING INSTRUCTIONS 8 531 p/n 305812 OpManual for Conveyor Hood CLEANING INSTRUCTIONS 8 531 p/n 305812 OpManual for Conveyor Hood TROUBLESHOOTING SUGGESTIONS TROUBLESHOOTING SUGGESTIONS SYMPTOM No operation, no lights REPLACE FILTER light remains lit (never shuts off) If filters are clean and fan is operating If fan is not operating PROBABLE CAUSE Cord unplugged Circuit breaker off or tripped Damaged power cord or plug Damaged power switch Filters dirty New filter still in plastic wrapper Exhaust opening blocked Filter opening blocked Vacuum hose kinked Vacuum line plugged Damaged vacuum switch Fan jammed Damaged motor start capacitor Damaged fan motor CORRECTIVE ACTION Plug cord into appropriate power receptacle. Reset circuit breaker Replace power cord Replace power switch Replace filters Remove plastic wrapper Clear or clean exhaust duct and opening Clear filter opening Unkink vacuum hose Clean or replace vacuum line Replace vacuum switch Unjam fan Replace start capacitor Replace fan motor 531 p/n 305812 OpManual for Conveyor Hood 9 SERVICE INSRTUCTIONS IMPORTANT: DO NOT store anything on top of the hood. DO NOT block the exhaust opening. Filter operation is monitored by a vacuum switch and a system of vacuum hoses. The switch energizes the REPLACE FILTER light if airflow through the filters is insufficient for efficient operation. The light is a warning only, and does not control the operation of the hood. VACUUM DIAGRAM WIRING DIAGRAM 10 531 p/n 305812 OpManual for Conveyor Hood PARTS & SERVICE PARTS & SERVICE DESCRIPTION PART NO. HIGH EFFICIENCY FILTER 16 x 20x 4 22862 CHARCOAL (CARBON) FILTER 14 x 20 x 7/8 22403 IMPORTANT: Use only factory authorized service parts and replacement filters. For factory authorized service, or to order factory authorized replacement parts, contact your Wells authorized service agency, or call: Wells Bloomfield, LLC 2 Erik Circle P. O. Box 280 Verdi, NV 89439 Service Parts Dept. phone: (775) 689-5707 fax: (775) 689-5976 Service Parts Department can supply you with the name and telephone number of the WELLS AUTHORIZED SERVICE AGENCY nearest you. CUSTOMER SERVICE DATA please have this information available if calling for service RESTAURANT _____________________________ LOCATION _____________ INSTALLATION DATE ________________...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias