Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação Whirlpool, Modelo 99044504A

Fabricante : Whirlpool
Arquivo Tamanho: 446.28 kb
Arquivo Nome : 55ce55f8-2573-4c5d-b46f-def26cb4b822.pdf
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


3. Use saber or keyhole saw to cut a rectangular opening for vent. 4. Repeat steps 1-3 for the underside of the top of the cabinet. 5./." (13.3 cm) 5./." (13.3 cm) *5./." (14 cm) *From wall, not cabinet frame Cabinet cutouts *1./." (3.8 cm) Wall Venting To make a 4" x 10." (10.2 cm x 26.7 cm) rectangle in the wall: 1. Make 2 lines by measuring from floor 65..." (167.3 cm) and 62..." (158.4 cm) or ..." (3.2 mm) and 3..." (9.2 cm) down from underside of cabinet and mark on the centerline on the back wall. 2. Mark lines 5." (13.3 cm) to the right and left of the centerline on the wall. 3. Use saber or keyhole saw to cut a rectangular opening in the wall for the vent. ..." 3 ..." Cabinet front 5 ..." (3.2 mm) (9.2 cm) (13.3 cm) Centerline Style 2 -Cut Openings for 7" (17.8 cm) Round Vent System Roof Venting To make a 7..." (18.4 cm) circle on the underside of the cabinet top and bottom: 1. Mark a centerline on the underside of the cabinet bottom. 2. Mark a line 5" (12.7 cm) from the back wall on the underside of the top of cabinet. 3. Draw a circle using a compass or 7..." (18.4 cm) circle template. 4. Use saber or keyhole saw to cut a 7..." (18.4 cm) diameter opening. 5. Repeat steps 1-4 for the underside of the top of the cabinet. Style 3 - Cut Openings for 3." x 10" (8.3 x 25.4 cm) Rectangular Vent to 7" (17.8 cm) Round Vent Transition Roof Venting To make a 4" x 10." (10.2 x 26.7 cm) rectangular cutout on the underside of cabinet bottom: 1. Mark lines 1." (3.8 cm) and 5." (14.0 cm) from the back wall on the centerline of the underside of cabinet. 2. Mark lines 5." (13.3 cm) to the right and left of the centerline on the underside of cabinet. 3. Use saber or keyhole saw to cut a rectangular opening for vent. 5./." (13.3 cm) 5./." (13.3 cm) *5./." (14 cm) *From wall, not cabinet frame *1./." (3.8 cm) To make a 7..." (18.4 cm) circle on the underside of the cabinet top: 1. Mark a centerline on the underside of the top of cabinet. 2. Mark a line 5" (12.7 cm) from the back wall on the underside of the top of cabinet. 3. Draw a circle using a compass or 7..." (18.4 cm) circle template. 4. Use saber or keyhole saw to cut a 7..." (18.4 cm) diameter opening. Install Vent System 1. Install vent through the vent opening in upper cabinet or wall. Complete venting system according to the selected venting method. See “Venting Requirements” section. 2. Use caulking to seal exterior wall or roof opening around the cap. 7 ./." (18.4 cm) diam. cabinet cutouts *From wall, notcabinet frame *5" (12.7 cm) 7 ./." (18.4 cm) diam. Cabinet cutouts *From wall, notcabinet frame *5" (12.7 cm) Install Range Hood 1. Remove terminal box cover. Depending on your installation, remove either back or top wiring knockout. A A. Terminal box cover 2. Remove the rectangular and round vent connectors from hood. Set the connectors and screws aside for use if connecting to a rectangular vent system. 3. For vented installations: ¦ Check that the louver cover is installed in front of hood. ¦ Remove either top or rear rectangular vent knockout. If using round vent, remove both top rectangular and semicircular knockouts. ¦ If using rectangular vent, attach rectangular damper/vent connectors. ¦ Reinstall round vent connector. NOTE: If the wall cap is directly behind the vent connector, the dampers in the connector and wall cap must not interfere with each other. Remove the vent connector damper if they interfere. For non-vented installations: ¦ Remove louver cover from front of hood. 4.Lift the range hood up under cabinet and determine final location by centering beneath cabinet. Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood. Set range hood aside on a covered surface. A A. Keyhole slot 5. Use ..." (3 mm) drill bit and drill 4 pilot holes as shown. A A. Drill pilot hole 6. Install the 4 - #10 x ..." mounting screws in pilot holes. Leave about ..." (6.4 cm) space between screw heads and cabinet to slide range hood into place. ..." (6.4 mm) WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 7. For Direct Wire Installations: ¦ Install a UL listed or CSA approved strain relief. A A. UL listed or CSA approved strain relief ¦ Pull about 12" (30 cm) of wire through wall or cabinet and into opening. For Power Supply Installations: ¦ Follow instructions included with power supply cord kit marked for range hoods. 8. Using 2 people, lift range hood into final position, feeding electrical wire through wiring opening. Position the range hood so that the large end of the keyhole slots are over the screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. 9. Check that damper, if used, rotates up and down freely. 10. For Vented Installations Only: Connect ventwork to hood. Seal...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias