Fabricante : Nilfisk-ALTO
Arquivo Tamanho: 4.2 mb
Arquivo Nome : d9d1bb63-37a7-464a-b21e-513fa1d8293b.pdf
|
Facilidade de uso
WARNING! To reduce the risk of fire, electric shock, or injury: • Do not leave the machine unattended when it is plugged-in. Unplug the unit from the power outlet when not in use. • Unplug the machine from the power outlet before cleaning or servicing. • Turn off all controls before unplugging. • To avoid electric shock, do not expose to rain or snow. Store and use indoors. • Wear hearing protection if desired. The measured sound level of the MX 521 H is 75dB(A). • Do not allow to be used as a toy. Close attention is necessary when used near children. • Use only as described in this manual. Use only the manufacturer’s recommended attachments. • Inspect the power cord regularly for damage, such as cracking, ageing, or damaged insulation. Replace the power cord with the same type as original if any damage is found. Do not use with damaged cord or plug. • Use a defoamer any time you get foam in the recovery tank, to prevent motor damage. • If foam or liquid comes out of the vacuum motor or exhaust, turn the machine off immediately. • If the machine is not working as it should, has been dropped, damaged, left outdoors or flooded with water, return it to a service center. • Do not pull the machine by the cord, do not use the cord as a handle, close a door on the cord, or pull the cord around sharp edges or corners. Do not run the machine over the cord. Keep the cord away from heated surfaces. To unplug, grasp the plug, not the cord. • Do not handle the plug, the cord, or the machine with wet hands. • Extension cords must be 12/3 and no longer than 50 feet. Replace the cord or unplug immediately if the ground prong becomes damaged. • Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair, and anything that may reduce air flow. • Do not pick up anything that is burning or smoking, such as cigarettes, matches, or hot ashes, or any health endangering dusts. Do not use to pick up flammable or combustible liquids such as gasoline or use in areas where they may be present. • Use extra care when cleaning on stairs. • Connect to a properly grounded outlet only. • Liquid pumped out could be dangerous because of temperature, pressure, or chemical content. • Do not let the pump run dry. If you run out of water, turn the machine off and refill 11-600205211REVA INSPECTION: Carefully unpack and inspect your MX 521 H for shipping damage. Each machine is tested and inspected before shipping. Any shipping damage incurred is the responsibility of the carrier. You should notify the carrier immediately if you notice damage to the box or to the machine or parts. CLEANING SOLUTIONS: We recommend liquid cleaning chemicals. Powder chemicals may be used, but unless mixed very thoroughly they could cause a build-up in the pump, lines, heat exchanger and/or quick disconnects. Any problem caused by a chemical build-up is not covered by warranty. Use a neutral cleaner with a pH between 6 and 9 to avoid premature wear of the pump, seals, and/or other components. Damage caused by the use of strong chemicals is not covered by the warranty. MAINTENANCE: For optimum performance flush the machine with clear water at the end of each working day. Once a month, minimum, run a flushing compound through the machine to break up any mineral or chemical build-up that may have formed. Lubricate the wheels, castors, and quick disconnects with an all purpose silicone spray. The vacuum and the pump do not require any maintenance. Clean the body with an all purpose detergent, and protect it with an automobile interior polish. Record the serial number and model of your new extractor here: Serial Number: __________________ Model: MX 521 H__ Purchase Date:________________ Write the name and phone number of your distributor: (and be sure to register your warranty) OIOIOISWITCH TURNS THE HEATER ON 5 1 VACUUM ON/OFF SWITCH PUMP ON/OFF SWITCH SELECT CARPET OR UPHOLSTERY2 3 4 RED LIGHT INDICATES THE HEATER IS HEATING GET FAMILIAR WITH YOUR NEW EXTRACTOR Dump Hose Switch Recovery Plate Tank Lid Vacuum Hose Cuff Solution Hose Connection LatchWheel Castor Solution Tank Lid Vaccum inlet to tank Recovery Tank Solution Tank OPERATION 1 Inspect the machine, hoses, and cleaning tools for cleanliness and completeness. 2 Fill the solution tank with water. Using warm water may be a benefit in cleaning effectiveness, but do not use hot water (above 54°C / 130° F) in the tank. 3 Plug in the power cord. NOTE: the red light (1) will turn on only when the heat exchanger is actively heating. 4 Connect the priming hose to the solution outlet quick disconnect on the machine, turn ON the pump switch (4) and prime the air out of the pump by allowing the water to flow unrestricted. When the water is clear (no air in it) and flowing smoothly, turn the pump switch OFF. Once the pump has stopped, remove the priming hose. NOTE: Never remove the priming hose if the pump is still running. To prime the pump, the solution tank should be full of liqu...