Log:
Assessments - 4, GPA: 3.5 ( )

Instruções de Operação Waterford Precision Cycles, Modelo Glass Island Hood

Fabricante : Waterford Precision Cycles
Arquivo Tamanho: 156.85 kb
Arquivo Nome : 9998467e-4a73-4ddf-88b4-77533670a9b9.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Always observe governing laws and regulations regarding ducting waste gases. All rec- ommendations given must be scrupulously observed to avoid any possible fire hazard. 2 CONTROL PANEL The control panel is situated on the front of the hood and comprises of a digital display and 5 touch control switches with the following functions: (See Fig.9) Fan ON/OFF Switch Reduces the speed of the fan (Min speed 1) Digital display,displays the speed of the fan 1-6 Increases the speed of the fan (Max speed 6) OFF delay switch, press once display flashes, fan switches off automatically after 15 minutes Light ON/OFF switch SPECIFICATIONS The electronic controls on your ducting cooker hood have multiple functions-features: Motor on-off Function The motor is turned on and off by pressing push-button no.1. When you turn on the cooker hood it automatically starts running at the third speed. Timer Function This function permits you to program your cooker hood so that the motor and lights turn off automatically 15 minutes after you have activated this function. To program press push-button no.4. At the bottom on the right of the display a point will flash indicating that the timer function is activated. Lights on-off Function To turn the lights on and off press push-button no. 5. Specific Features The electronic controls provided on your ducting cooker hood have advanced features to facilitate maintenance and correct utilisation. Prompt-Clean Metal Filters After every 30 hours of use a microprocessor, prompts the user that it is time to clean the metal grease filters to guarantee better ducting performance and to improve hygiene. This prompt is indicated by the letter “A” which flashes on the display. To delete this prompt, once the filters have been cleaned and with the cooker hood off (not powered), maintain push-button 2 pressed for more than 5 seconds. When you press this push-button the letter “A” will come up on the display and then disappear after 5 seconds. The microprocessor zeros the number of hours and starts a new count from zero until reaching 30 hours prompting this maintenance procedure. VENTILATION If there is an appliance fitted in the vicinity which requires air for combustion, additional air vents will be required to alleviate the possibility of spillage of products of combustion, from the appliance/flue while the fan is in operation. Refer to B.S. 5440 Part 2 & I.S. 813. Where such an installation exists a test for spillage should be carried out with all appliances requiring air for combustion and all extraction fans running at maximum rate, (i.e. tumble dryers, extraction fans) with all external windows and doors closed. If spillage occurs following the above operation, an additional air vent of sufficient size to prevent this occurrence should be installed. FITTING INSTRUCTIONS 1. Fix the ceiling bracket to the ceiling, making sure that the riveted brackets for fixing the stainless steel casing are to the side. Adjust the chimney section to the required length. See Fig. 2 & 2a. 2. Slide the stainless casing over the chimney section keeping vents to the side. See Fig.3. 3. Mount the chimney section on the ceiling bracket, note tabs must fit into the slots on the ceiling bracket to hold this section in place while fitting the fixing screws. See Fig.4. 4. Fit 4 fixing screws one in each corner. See Fig. 5. Fit the glass onto the hood section using clamps provided (See Fig 6). Connect the plug and socket between the chimney and the hood section. 5. Lift the glass section into place, the clip on either side will hold hood in place while fitting the fixing screws. See Fig 7. 3 THE MANUFACTURER WILL NOT BE RESPONSIBLE IF THESE RECOMMENDATIONS AND INSTRUCTIONS REGARDING INSTALLATION, MAINTENANCE AND USE ARE NOT OBSERVED AND RESPECTED WHEN USING THE COOKER HOOD. Fig.1 Fig.3 Riveted Brackets Vents Fig.2 Fig.2a 4 Fig.4 Fig.5 Fig.6 Clips to hold Hood Glass glass in place 5 Fig.7 DIMENSIONS 6 An AGA Company WARRANTY We undertake to repair or replace, free of charge to you any part found to be faulty within the 12 month period from the date of purchase provided that: * The fault is, in our opinion, caused by defective workmanship, or material and not by accident, misuse, neglect or normal wear and tear. * Any manufacturing defect is reported to the stockist from whom you bought the appliance within 12 months of the date of purchase. * The Waterford appliance is installed to the Manufacturer’s recommendations and by a suitably qualified person. * The guarantee registration form is completed fully and returned to us within 30 days of the purchase date. IMPORTANT NOTICE: Any alteration to this appliance that is not approved in writing by Waterford Stanley will render the guarantee void. Waterford Stanley Ltd., Unit 210, IDA Industrial Estate, Cork Road, Waterford, Ireland. Tel: (051) 302300 Fax (051) 302315 Rev: 001 DP 080212 7 ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias