Facilidade de uso


Install the suspension bracket to joists by using long screws (ST4.2X20) and secure it to the fan body by using screw II (ST4.2X12) (Fig.3) 4. Remove junction box cover and secure conduit or stress relief to junction box knock-out hole. (Fig.4) 6. Install a circular duct and secure it with duct tape or clamps. 5. Refer to wiring diagramof page 5. Follow all the local electrical safety codes as well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires: black to black; white to white; green to green; For model FV-08VKSL2 connect the two red wires to the switch for the speed control. Replace the junction box cover. (Fig.4) Mount junction box cover carefully so that lead wires are not pinched. CAUTION: Joist Joist Joist Duct tape or clamps Circular duct Conduit (FV-08VKML2) (FV-08VKSL2) Junction box cover Fig.2-1 Fig.2-2 Fig.3 Fig.4 Fan body Fan body 2 Long screws (ST4.2X20) 2 Long screws (ST4.2X20) Screws II (ST4.2X12) 4 Long screws (ST4.2X20) Joist 9 Conduit Red wires Green wires Lead wires Wire nut Junction box Green wires Lead wires Wire nut Junction box Conduit 7. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.5) 8. Insert the plug connector into the receptacle , and secure the lighting unit to the fan body with 1 screw (ST4.2X16) and 2 machine screws (M4X8). (Fig.5) II II III 9. Insert the fluorescent lamps and secure the night lamp into the lighting unit . (Fig.5) 10. Insert mounting spring into the slot as shown and adjust high/lowdelay time preset switch and low speed air volume preset switch. Refer to switch indication on page 5 (FV-08VKML2) (Fig.6-1) 11. Insert the sensor unit into the housing of the grille and insert other mounting spring into the slot as shown and mount grille to fan body (FV-08VKML2) (Fig.6-2, Fig.6-3) 12. Insert mounting springs into the slots as shown and mount grille to fan body. (FV-08VKSL2) (Fig.7) Mount grille carefully so that lead wire of sensor unit is not pinched. CAUTION: INSTALLATION (JOIST MOUNTING- ) CONTINUED Ceiling Lighting unit Machine screw (M4X8) Machine screw (M4X8) Screw III (ST4.2X16) Fluorescent lamps 4 W Night lamp Inches (mm) Plug connector II Mounting spring Mounting spring Ceiling Ceiling Ceiling Ceiling Grille Grille Grille Gloves Grille Slot Lighting unit Lighting unit Sensor unit Sensor unit Fig.5 Fig.6-1 Fig.6-2 Fig.6-3 Fig.7 Gloves 10 Receptacle II Plug connector II Gloves Gloves The machine screws must be tight fit. CAUTION: (FV-08VKML2) (FV-08VKSL2) Fig.8 Fig.9 Fig.10 Circular duct Conduit Inches (mm) Joist Junction box cover INSTALLATION (JOIST MOUNTING- ) (When spacing the fan body flange belowthe drywall or resilient channel) 1. Remove the machine screw by using screwdriver, disconnect plug connector fromreceptacle and remove adaptor fromfan body before installation, (Fig.8) 4. Insert the suspension bracket into fan body (refering to step 1 of installation I, page 8) 5. Insert the fan body into joists. (Fig.10) IMPORTANT: Make sure that adaptor claws are properly inserted into fan body slots. 2. Insert the suspension bracket into the adaptor and secure it to joists by using long screws (ST4.2X20) (Fig.9) Keep the distance B (1/ inch, 12.7mmor 5/8 inch, 15.9mm) for the thickness of ceiling board. 2 Spacing A between Joists inches (mm) Suspension bracket Suspension bracket I Suspension bracket III Suspension bracket II III If spacing A between joists is 21 1/4 to 23 1/ inches (540 to 597mm), connect suspension bracket and (C4 mark to C4 mark) according to page. 8 Select the suspension bracket according to spacing A as shown below: II III 2 13 1/4 15 1/ (336 394) ~ ~ 2 16 1/ 18 3/4 (419 ) ~ ~480 2 21 1/4 23 1/ (540 597) ~ ~ 2 Machine screw Screwdriver Fan body Fan body Slots Adaptor claws Gloves Gloves Gloves Gloves Adaptor Adaptor 2 Long screws (ST4.2X20) 2 Long screws (ST4.2X20) Joists Suspension bracket I Suspension bracket 16 1/2~18 3/4 (419~480) 13 1/4~15 1/2 (336~394) 21 1/4~23 1/2 (540~597) 1/2(12.7) 5/8 (15.9) 11 Receptacle Receptacle plug connector plug connector INSTALLATION (JOIST MOUNTING) CONTINUED INSTALLATION (JOIST MOUNTING) CONTINUED (FV-08VKML2) (FV-08VKSL2) Screw driver Screw (ST4.2X12) II 2 Long screws (ST4.2X20) Screw (ST4.2X12) II 2 Long screws (ST4.2X20) 4 Long screws (ST4.2X20) Machine screw Plug connector Receptacle Fig.11 Fig.12 Fig.13 Fig.14 I-joist Suspension bracket III INSTALLATION ( -JOIST MOUNTING) 6. Secure the fan body to adaptor by using machine screw and plug connector to receptacle (Fig.11) 7. Secure the suspension bracket to joists by using long screws (ST4.2X20) and secure it to fan body by using screw (ST4.2X12) in vertical direction (Fig.12) II 8. Follow steps 7 to 12 of Installation (page 10) to complete the installation work. I C1 C2 C3 C4 Suspension bracket The suspension bracket can comply with different kind of -joists. III III I 1. Before installation, secure the lighting unit to fan body (referin...

Este manual também é adequado para os modelos :
Fans - FV-08VKSL2 (871.3 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias