Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Vermont Casting, Modelo 360DVS2

Fabricante : Vermont Casting
Arquivo Tamanho: 1.94 mb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


10006326 360DVS Series Direct Vent Fireplaces B120B121B122B123B124B126B125LG320 Side of Fireplace Venting Side Fig. 40 360DVS log placement. Side of Fireplace B121 B123 B120 B122 B126 Fig. 41 360DVS log placement. Lava Rock and Ember Material Placement Your log set contains Ember Material and two types of Lava Rocks. Set these materials in place after the logs have been installed. Ember Material (Pt. #51915) Remove ember material from the bag and separate it into small pieces, then scatter it over burner tiles in a random fashion. Do not pack down ember material; leave it in a ‘fluffy’ state. Lava Rock (Pt. #10001454) Remove lav rock material from packaging and spread it over ceramic floor panels outside log stack. Do not place this lava rock material on burner tiles. B125 LG321 Flame & Temperature Adjustment RN/ RP Models For units equipped with ‘HI/LO’ valves the flame adjustment is accomplished by rotating the ‘HI/LO’ adjustment knob located near the center of the gas control valve. (Fig. 42 and Fig. 43) LOHI Turn counterclockwise to decrease flame height Turn clockwise to increase flame height Fig. 42 Flame adjustment knob for Honeywell valve. 10006326 25 360 DVS Series Direct Vent Fireplaces Turn counterclockwise to increase flame height LOHITurn clockwise to decrease flame height Fig. 43 Flame adjustment knob for SIT valve. Flame Characteristics 3/8” - 1/2” (10 - 13mm) F584-703 Fig. 45 Correct pilot flame appearance. It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the pictorials illustrated below. (Figs. 45 & 46) If the flame patterns appear abnormal, contact a qualified service provider for service and adjustment. LG323 LG322 Fig. 46 Correct log flame appearance. 26 10006326 360 DVS Series Direct Vent Fireplaces Maintenance Burner and Burner Compartment It is important to keep the burner and the burner compartment clean. At least once per year remove the logs and lava rock/ember material. Vacuum and wipe out the burner compartment. Remove and refit the logs per the instructions in this manual. Always handle the logs with care as they are fragile and may also be hot if the fireplace has been in use. FK24/FK12 Fan Assembly The fan unit requires periodic cleaning. At least once per month in the operating season, open the lower louvre panels and wipe or vacuum the area around the fan to remove any build up of dust or lint. Brass Trim Clean the brass trim pieces using a soft cloth lightly dampened with lemon oil. Do not use water or household cleaners on any brass components. Cleaning the Standing Pilot Control System The burner and control system consists of: • burner tube • gas orifice • pilot assembly • thermopile • millivolt gas valve Most of these components may require only an occasional checkup and cleaning and some may require adjustment. If repair is necessary, it should be performed by a qualified technician. 1. Turn off pilot light at gas valve side. 2. Let fireplace cool if it has been running. 3. Remove window frame assembly. (Refer to Window Frame Assembly Removal section) 4. Remove logs. 5. Vacuum burner compartment especially around orifice primary air openings. 6. Visually inspect pilot. Brush or blow away any dust or lint accumulation. 7. Reinstall logs. 8. Ignite pilot; refer to Lighting Instructions. 9. Reinstall window frame assembly. To obtain proper operation, it is imperative that the pilot and burner’s flame characteristics are steady, not lifting or floating. Typically, the top 3/8 – 1/2” (10 – 13 mm) of the thermopile should be engulfed in the pilot flame. (Page 26, Fig. 46) To adjust pilot burner (to be done by a qualified service technician): 1. Remove pilot adjustment cap. 2. Adjust pilot screw to provide properly sized flame. 3. Replace pilot adjustment cap. The primary air shutter is set at factory and should be adjusted, if necessary, only by a qualified service technician. Cleaning Electronic Ignition System The Electronic Ignition burner/control system consists of: • main burner • gas orifice • pilot burner • 24VAC valve with transformer The process for taking care of Electronic Ignition units is identical to that for taking care of Standing Pilot models. 34 10006326 35 360DVS Series Direct Vent Fireplaces 10006326 LOHI PILOT ADJ PILOT ON OFF 4a/b 5a/b 6 9 11 11 8 10 7 12 18 24 27 17 2 29 28 22 23 26 21 20 25 19 13 14 3a/b 15a/b 16a/b 6326 360DVS parts 31a/b 32 35 33 HI LO 34a/b 25 36 37 30 1 1a 1b 1c 1d 1e 1f 1g CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 360DVS Series 360 DVS Series Direct Vent Fireplaces 360DVS Series (Items marked ‘*’ are not shown in the parts illustration) Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR 1. Log Set (complete) 10006350 10006350 10006350 10006350 1a. Log - Rear (B120) 10006315 10006315 10006315 10006315 1b. Log - Front Left (B121) 10006316 10006316 10006316 1000631...

Este manual também é adequado para os modelos :
Fans - 360DVS3 (1.94 mb)
Fans - 360DVSL (1.94 mb)
Fans - 360DVSR (1.94 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias