Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação American Standard, Modelo ERVR300A9P00A

Fabricante : American Standard
Arquivo Tamanho: 45.19 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Press the fan icon until the light for the percent desired is on. TO TURN THE ERV OFF: Press the fan icon until all lights are off. The control is off. The ERV motor is de-energized. (Power is still persent inside the unit. Always unplug cord from outlet before servicing!) GENERAL SETTINGS: For systems installed in an area with high humidity. The Percent Timer should be set to deliver the Minimum Ventilation Requirements. VACATION SETTINGS: For systems installed in an area with high humidity. If the A/C system thermostat setting is elevated or set up while on vacation or for extended periods of time (over 2 days), the Percent Timer and ERV should be turned OFF. After returning from vacation or when the system thermostat is lowered to normal daily setting, the Percent Timer and ERV should be reset to the previous runtime %. WHEN WINDOWS ARE OPEN: When windows are open in your home the Percent Timer and ERV should be turned OFF. NOTE for ERV systems with more than one control: Another control may be causing your ventilator to run -even if the runtime % light on this control is off. If you wish to keep your ventilator from running, check that none of your controls are calling for unit operation. Installation 1. Install control in a standard 2" x 4" electrical box, with a minimum depth of 1.5", with the two screws provided. 2. Wire Size: 18 gauge, no more than 500 feet. Wiring is non-polar. 3. The two wires from the ERV should be attached to the ‘C’ and ‘R’ positions on the terminal block on the back of the PT Control. See Figure 13. 4. Use Lutron Decora™ cover plate to complete the installation (supplied by installer). PUSH BUTTON POINT-OF-USE CONTROL (OPTIONAL ACCESSORY) For use with all ERV models Operation The Push Button (PB) Point-of-use Control lets you manually turn on your energy recovery ventilator for a short period of operation – for example, when you are using a bathroom. The PB Control must be connected to a PT control to operate. 20-40-60 minute ventilation control: Press the fan icon and your ventilator will run for 20 minutes (See Figure 3). Press again and the unit will run 40 minutes. A third press provides for 60 minutes of operation. Percent Timer Control does not need to be on for the PB Control to operate the ERV unit. You can cancel a cycle at anytime. Just press the fan icon and hold for about five seconds. You can start another cycle by pressing the fan icon. NOTE for ERV systems with more thanone control: Another control other than the push button may be causing your ventilator to run. If you wish to keep your ventilator from running, check that none of your controls are calling for unit operation. Installation 4. Install control in a standard 2" x 4" electrical box, with a minimum depth of 1.5", with the two screws provided. 5. Wire Size: 18 gauge, no more than 500 feet. Wiring is non-polar. 6. Two wires from the PB Control should be attached to the ‘PB” positions on the terminal block on the back of the Percent Timer Control. 7. For two PB controls, one wire from each can be twisted together and inserted into a single position on the terminal block on the Percent Timer Control. The wires must be a 18 gage solid wire. If more than two PB controls are attached or 18 gage stranded wire is used then pigtails must be inserted into the ‘PB’ positions on the Percent Timer Control and the leads attached to the pigtails with wire nuts. 8. Use Lutron Decora™ cover plate to complete installation. User’s Information Limited Warranty Energy Recovery Ventilator (ERV) ERVR100, 200, 300 (Parts Only) Models for Residential Use* This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding owner of the real property to which the ERV is originally affixed, and applies to products purchased and retained for use within the U.S.A. and Canada only. If any internal functional part of your ERV fails because of a manufacturing defect within five years from the date of the original purchase, Warrantor will furnish without charge the required replacement part. Any local transportation, related service labor, diagnosis calls, and related items are not included. If compatible ERV controls are incorporated in the HVAC system and are installed at the same time as your ERV, then if any Warrantor furnished internal functional part of the ERV controls fail because of a manufacturing defect within five years from the date of original purchase, Warrantor will furnish the required replacement part. Any local transportation, related service labor, diagnosis calls, refrigerant and related items are not included. THIS LIMITED WARRANTY IS IN LIEU OF ANY EXPRESS WRITTEN LIMITED WARRANTY ACCOMPANYING ANY OF THE ABOVE INDOOR PRODUCTS. If the heat transfer core should become defective because of a manufacturing defect within ten years from the date of original purchase, Warrantor will furnish without charge the required replacement heat transfer core. Any local transportation, rela...

Este manual também é adequado para os modelos :
Fans - ERVR100A9P00A (45.19 kb)
Fans - ERVR200A9P00A (45.19 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias