Log:
Assessments - 2, GPA: 5 ( )

Instruções de Operação Hunter Fan, Modelo 43041-01

Fabricante : Hunter Fan
Arquivo Tamanho: 10.08 mb
Arquivo Nome : 43041.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


If you have questions, contact the manufacturer. 2. Before servicing or cleaning the unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. when the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. 3. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. 4. Sufficient air is needed for proper combustion and exhausting of gasses through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards, such as those published by the National Fire Prevention Association (NFPA), and the American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) - protected branch circuit. 8. Never place a switch where it can be reached from a tub or shower. 9. Install fan at least 5 feet (1.52 m) above the floor. 10. This unit must be grounded. 11. Unit must not be installed in a ceiling thermally insulated to a value greater than R40. CAUTION Warning ! ! 1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. 2. To avoid motor bearing damage and noisy/unbalanced impellers, keep drywall spray, construction dust, etc. off power unit. 3. DO NOT install this product in a wall. This product is designed for installation in ceilings up to a 12/12 pitch (45 degrees). Ductwork must point upward. 4. Please read specification label on product for further information and requirements. DISCONNECT ELECTRIC POWER SUPPLY AND LOCK OUT SERVICE PANEL BEFORE SERVICING UNIT PREVENTATIVE MAINTENANCE A clean fan provides better service. Disconnect the power supply and clean the fan as listed below. TO CLEAN GRILLE: Use a mild detergent, such as dishwashing liquid, and a soft cloth. DO NOT use abrasive cloths, steel wool pads or scouring powders. TO CLEAN FAN ASSEMBLY: Unplug motor cord from receptacle. To remove motor plate, find the single tab on the motor plate (located next to the receptacle). Push up rear motor plate tab while pushing out on the side of the housing or insert a screwdriver into the slot in the housing (next to tab) and twist screwdriver. Gently vacuum fan, motor and interior of housing. METAL AND ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER. MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. COOKING AREA Do Not Install Above Or Inside This Area 45° 45° Floor Cooking Equipment * x4 * x2 B I C A Check all the parts. If damaged, call 1-888-830-1326 for replacements. Extra Screws 3/8” Cable Connector * NOTE: Strain relief cable connector must be installed. Not Included. 95044-01-000 D 95029-01-000 E 75191-01-000 F 03242-07-133 G 98037-01-000 H 74508-03-133 I x2 77521-01-000 J 65219-01-000 K 97956-01-000 L 75184-01-133 M 97958-01-000 N 77537-01-000 O Included. Tools Needed. Estimated assembly time: 30 to 60 minutes Before Installation NOTE: Remove all packing materials before installation. 2 1 I H Loosen screws. Turn off the power source. 4 3 H E Remove the motor/blower from the housing. Remove packing material. 5 6 Remove the pre-loaded screw tip covers. Back out the pre-loaded screw tips until flush with the side of the housing. 7 8 F G Remove the wiring cover screw. Remove the wiring cover. 9 10 E C B Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Choose Installation Option For New Construction - attaching to joist fo to step A11, page 6 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page 15 5/81/2 New Construction – attaching to joist A12 A11 E Screw pre-loaded screws into joist or framing. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. A13 Pull wires through the strain relief. A14 Ground Black Green 2 Pin Bare Copper A White Black Main Switch 1 (AC In) Fan Motor White F White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. 0 A16 A15 E F G Connect 4” duct and vent to the outside. Tape joints. If duct...

Este manual também é adequado para os modelos :
Fans - 81021 (10.08 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias