MAINTENANCE The motor is permanently lubricated and never needs oiling. If the motor bearings are making excessive or unusual noises, replace the motor with the exact service motor. You should replace the impeller at the same time. 2 American Society for Heating, Refrigeration and Air-Conditioning Engineers (ASHRAE), and the local code authorities. 5. When cutting or drilling into wall(s) or ceiling, do not damage electrical wiring or other hidden utilities. 6. Ducted fans must always be vented to the outdoors. 7. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) – protected branch circuit. 8. Never place a switch where it can be reached from a tub or shower. 9. Install fan at least 5 feet (1.52 m) above the floor. 10. This unit must be grounded. 11. Unit must not be installed in a ceiling thermally insulated to a value greater than R40. W ARNING DISCONNECT ELECTRIC pOWER SUppLY AND LOCK OUT SERVICE pANEL BEFORE SERVICING UNIT Do Not Install Above Or Inside This Area Cooking Equipment Floor 45° 45° COOKING AREA 41718-01 01/28/2008 028_41718_EngS_1.28.08_Arial.indd 2 1/28/08 10:47:06 AM 41718-01 01/28/2008 3 D E F G H I L M N x4 * * *NOTE: Strain relief cable connector must be installed. Not Included. A B C 95044-01-000 95029-01-000 75191-01-000 03242-07-133 95491-01-000 74508-03-133 95583-01/02/03/04-000 J 77521-01 K 65219 75184-01-133 94990-01/02/03-000 x2 I Extra Screws 3/8” Cable Connector x2 1 Turn off the power source. Tools Needed. (Not supplied) Estimated assembly time: 30 to 60 minutes Before Installation Check all the parts. If damaged, call 1-888-830-1326 for replacements. Included. 2 E I Loosen screws. NOTE: Remove all packing materials before installation. 028_41718_EngS_1.28.08_Arial.indd 3 1/28/08 10:47:09 AM 41718-01 01/28/2008 4 5 4 7 G 8 F Remove the motor/blower from the housing. H E 3 Remove the pre-loaded screw tip covers. Remove the wiring cover screw. 6 Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover. Remove packing material. 028_41718_EngS_1.28.08_Arial.indd 4 1/28/08 10:47:11 AM 41718-01 01/28/2008 5 9 E Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction - attaching to joist 10 B C Choose Installation Option For New Construction - attaching to joist go to step A11, page 5 For New Construction - suspended between joists go to step B11, page 8 For Existing Construction - accessible from above go to step C11, page 11 For Existing Construction - accessible only from below go to step D11, page15 A11 E 5/8 1/2 5/8 1/2 A12 Screw pre-loaded screws into joist or framing. 028_41718_EngS_1.28.08_Arial.indd 5 1/28/08 10:47:13 AM 41718-01 01/28/2008 6 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A14 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option A13 Pull wires through the strain relief. Connect wires as shown. A016 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. A15 E G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 028_41718_EngS_1.28.08_Arial.indd 6 1/28/08 10:47:15 AM 41718-01 01/28/2008 7 A19 I Secure the motor by tightening the 2 screws. A20 Turn on the power source. Connect wiring from the motor to the wiring cover plate. 0 A17 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. 0 H A18 ON OFF A21 Test the motor. If the motor does not run, check the plug connection. A22 E1 Go to step on page 17 to attach grille. 028_41718_EngS_1.28.08_Arial.indd 7 1/28/08 10:47:18 AM 41718-01 01/28/2008 8 B11 D E 5/8 1/2 5/8 1/2 B12 1/8” Bit B14 B15 B16 E B13 Slide the mounting rails into brackets. Mark position of screws by using holes as a template. Insert screws, leaving space between the screw head and the joist. Screws are not provided. New Construction – suspended between joists Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Drill a hole in the center of each outline. Attach the rails onto the screws. 028_41718_EngS_1.28.08_Arial.indd 8 1/28/08 10:47:21 AM 41718-01 01/28/2008 9 Tighten screws. Pull wires through the strain relief. Connect wires as shown. B17 B18 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B19 Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option B21 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may n...

Este manual também é adequado para os modelos :
Fans - Saturn 90052 (6.64 mb)
Fans - Saturn 90054 (6.64 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias