Facilidade de uso


8. Never place a switch where it can be reached from a tub or shower. 9. Install fan at least 5 feet (1.52 m) above the floor. 10. This unit must be grounded. 11. Unit must not be installed in a ceiling thermally insulated to a value greater than R40. 12. For supply connection, use wires suitable for at least 90. C (194. F). Do Not Install Above Or Inside This Area Cooking Equipment Floor 45° 45° COOKING AREA 41937-01 10/26/2010 3 E F G H I L M N 95047-03-000 77481-01-000 03242-07-133 95261-02-000 74508-03-133 96397-01-214 for model 81001 96397-02-444 for model 81003 75184-01-133 86812-01-000 J 77522-01 K 65219 O 75733-01-214 for model 81001 75733-01-444 for model 81003 x4 * * *NOTE: Strain relief cable connector must be installed. Not Included. A B C x2 D Extra Screws 3/8” Cable Connector x2 1 Turn off the power source. Tools Needed. (Not supplied.) Estimated assembly time: 30 to 60 minutes Before Installation Check all the parts. If damaged, call 1-888-830-1326 for replacements. Included. 2 E I Loosen screws. NOTE: Remove all packing materials before installation. 41937-01 10/26/2010 4 5 4 7 G 8 F Remove the motor/blower from the housing. H E 3 Remove the pre-loaded screw tip covers. Remove the wiring cover screw. 6 Back out the pre-loaded screw tips until flush with the side of the housing. Remove the wiring cover. Remove packing material. 41937-01 10/26/2010 5 9 E Pop out the first wiring access slug. Use second if needed. Insert the strain relief (not included) into the housing and secure with washer. Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. New Construction 10 B C Choose Installation Option For New Construction - go to step A11, page 5 For Existing Construction - go to step B11, page 8 A11 E 5/8 1/2 5/8 1/2 A12 Screw pre-loaded screws into joist or framing. 41937-01 10/26/2010 6 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper A14 Ground Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option Connect wires as shown. A13 Route wires through the strain relief. For supply connection, use wires suitable for at least 90. C (194. F). A016 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. A15 E G F Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. 41937-01 10/26/2010 7 A19 I A20 Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Secure the motor by tightening the 2 screws. Turn on the power source. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. A17 0 0 H A18 ON OFF A21 Test the motor. If the motor does not run, check the plug connection. A22 C1 Go to step on page 10 to attach grille. 41937-01 10/26/2010 8 B11 EXISTING FAN E B12 Existing Construction B13 2 1 B14 Route wires through the strain relief. For supply connection, use wires suitable for at least 90. C (194. F). Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7 1/4”x 7 3/4”). Move the housing into position above the ceiling. Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. E B15 Install the housing flush with the sheetrock and secure by tightening the pre-loaded screws into the joist. 41937-01 10/26/2010 9 H B18 H B19 B20 I Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Connect wiring harness. DO NOT ALLOW THE MOTOR TO HANG FROM THE WIRING HARNESS. Secure the motor by tightening the 2 screws. A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper B16 Ground Main Switch 1 (AC In) *Option Fan & Main Light Together Switch 2 (AC In) *Option Connect wires as shown. F B17 G Install the wiring cover plate. 41937-01 10/26/2010 10 ON OFF B22 B23 C1 Go to step on page 10 to attach grille. B21 Test the motor. If the motor does not run, check the plug connection. Turn on the power source. L O C2 M N C1 Attaching the Grille Remove the thumbscrews. Remove glass dome. 41937-01 10/26/2010 11 C4 K C5 J C6 Remove the strain relief bracket screw. Position the strain relief bracket under the motor as shown. Insert the strain relief bracket’s dog-leg tab so that it hooks over the lip of the motor. Reinstall the strain relief bracket screw. L C3 Connect wiring harness. DO NOT ALLOW THE FIXTURE TO HANG FROM THE WIRING HARNESS. C7 L L C8 M Align posts 1, 2, and 3 (stamped into motor housing) with posts 1, 2, and 3 (stamped into light fixture). Slide light fixture over posts. Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. 41937-01 10/26/20...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias