Log:
Assessments - 3, GPA: 4.3 ( )

Instruções de Operação Air King, Modelo AK100LSL

Fabricante : Air King
Arquivo Tamanho: 190.52 kb
Arquivo Nome : 7d9bbb9a-9867-4100-a0aa-9dbd6a5f70a7.pdf
Língua de Ensino: enfr
Ir para baixar



Facilidade de uso


FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE. GENERAL SAFETY INFORMATION When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to person, including the following: 1. Read all instructions before installing or using exhaust fan. 6. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. 2. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. 7. Ducted fans must always be vented to the outdoors. 3. Before servicing or cleaning the unit, switch power off at 8. This unit must be grounded. service panel and lock the service disconnecting means to 9. To avoid motor bearing damage and noisy and/or unbalanced prevent power from being switched on accidentally. When impellers, keep drywall spray, construction dust, etc. off the service disconnecting means cannot be locked, securely power unit. fasten a prominent warning device, such as a tag, to the service panel. WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, 4. Installation work and electrical wiring must be done by DO NOT USE THIS FAN WITH ANY SOLID-STATE SPEED CONTROL DEVICE. qualified person(s) in accordance with all applicable codes and standards, including fire-related construction. 10. Acceptable for use over a bathtub or shower when installed 5. Sufficient air is needed for proper combustion and exhausting in a GFCI protected branch circuit. of gases through the flue (chimney) of fuel burning equipment 11. NEVER place a switch where it can be reached from a tub or to prevent back drafting. Follow the heating equipment shower. manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA) WARNING: DO NOT USE IN KITCHENS and the American Society for Heating, Refrigeration, and Air Conditioning Engineers (ASHRAE), and the local code authorities. CAUTION: FOR GENERAL VENTILATING USE ONLY. DO NOT USE TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS. SAVE THESE INSTRUCTIONS 210572080 Rev. A 8-05 1 of 12 INSTALLATION INSTRUCTIONS CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. SECTION 1 Preparing the Exhaust Fan 1. Unpack fan from the carton and confirm that all pieces are present. In addition to the exhaust fan you should have: 1 - Grill 1 - Damper Assembly (attached) 4 - Mounting Rails 2 - 13 Watt Fluorescent Bulbs 1 - Instruction/Safety Sheet 2. Choose the location for your fan. To ensure the best air and sound performance, it is recommended that the length of ducting and the number of elbows be kept to a minimum, and that insulated hard ducting be used. Larger duct sizes will reduce noise and airflow restrictions. This fan will require at least 8" of clearance in the ceiling or wall, and will mount through drywall up to 3/4" thick. The fan mounts between 16" or 24" on center joists using the 4 provided mounting rails. 3. Select the most convenient electrical knockout and remove using a straight-blade screw driver (Figure 1). SECTION 2 Figure 1 New Construction 1. Install the rails on the housing and position the housing next to the joist. Line up housing so that it will be flush with the finished ceiling. Secure the ends of the rails with screws or nails (not included) to the joists and slide the housing into the final position (Figure 2). Figure 2 Joist Housing Mounting Rails SECTION 3 Existing Construction 1. Set housing in position between the joist and trace an outline onto the ceiling material (Figure 3). Set housing aside and cut opening, being careful not to cut or damage any electrical or other hidden utilities. Install the rails on the housing and position the housing in the previously cut hole so that it is flush with the finished ceiling. Secure the ends of the rails to the joists (Figure 2). SECTION 4 Ducting CAUTION: ALL DUCTING MUST COMPLY WITH LOCAL AND NATIONAL BUILDING CODES. 1. Connect the ducting to the fan’s duct collar (Figure 4). Secure in place using tape or screw clamp. Always duct the fan to Figure 3 Joist the outside through a wall or roof cap. SECTION 5 Wiring CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. CAUTION: ALL ELECTRICAL CONNECTIONS MUST BE MADE IN ACCORDANCE WITH LOCAL CODES, ORDINANCES, OR NATIONAL ELECTRICAL CODE. IF YOU ARE UNFAMILIAR WITH METHODS OF INSTALLING ELECTRICAL WIRING, SECURE THE SERVICES OF A QUALIFIED ELECTRICIAN. NOTE: This unit includes a side access panel for wiring that does not require the removal of the fan’s blower assembly. If you choose to wire the unit from the inside, you will need to remove the blower assembly and internal wiring compartment. Both methods are equally effective. 1a. External Wire Compartment: Remove the wire compartment cover screw and plac...

Este manual também é adequado para os modelos :
Fans - AK80LSL (190.52 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias