Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Venmar, Modelo QDE

Fabricante : Venmar
Arquivo Tamanho: 3.12 mb
Arquivo Nome :
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


If using 6'' (150 mm) round ducts, use a transition. Use 2'' (50 mm) metal foil duct tape to seal joints. 2. MEASURE THE INSTALLATION Dimensions for the most common installations are shown below. We recommend to install the hood at a minimum of 20” (508 mm) from an electric range and at 24” (610 mm) from a gas range. For optimal performance, the hood should not be installed more than 30” (762 mm) from cooktop. - 4 - 3. PREPARE THE INSTALLATION Make sure the following items are included: - Hood - Filters (2) - Adapter/damper assembly 3%” x 10'' (located inside the hood, under the bottom panel) - Compact fluorescent lamps (120 V, 13 W, PLC13, 2700 K with G24q-1 base) (packed behind the light diffuser) - Parts bag (located inside the hood, under the bottom panel) including: 1 wire clamp, 5 no. 8 x 1/2'' double thread screws, 2 wire connectors and 6 no. 6 x 1/2'' screws Part sold separately: - Transition 3%”x 10” to 6” round (optional, for 6” round ducts installation only) CAUTION |When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves. | Cut-out the openings for duct (A) and power cable (B), in cabinet or wall, according to the direction of discharge chosen. See figures below. Horizontal discharge: Vertical discharge: 4. PREPARE THE HOOD Remove both filters from the hood. Disassemble the adapter/damper (A) from the hood. NOTE: The adapter/damper is located inside the hood. Remove the bottom panel (B) to access the adapter/damper. Refer to figure beside. - 5 - 4. PREPARE THE HOOD (CONT’D) Punch out the appropriate electrical knock-out hole. Using a long nose pliers, remove the knock-out for the chosen opening (vertical on top or horizontal at the back of the hood). See figures below. Vertical discharge Horizontal discharge 5. INSTALL THE ADAPTER/DAMPER NOTE: If this hood replaces another one, please note that the location of the air exhaust can vary from one manufacturer to another. Horizontal discharge, new installation Fold down the foldable flange (C) of the adapter/damper. This flange must be at 90° from the remaining flanges. Use the lower screw holes on each side of the adapter/damper to assemble it to the back of hood. See below. Horizontal discharge, hood replacement It may be necessary to adjust the adapter/damper location to the existing wall discharge opening. Leave the foldable flange (C) of the adapter/damper as is. Use the upper screw holes on each side of the adapter/damper to assemble it to the back of hood. See below. - 6 - 5. INSTALL THE ADAPTER/DAMPER (CONT’D) Vertical discharge For a vertical discharge installation only, leave the foldable flange (C) of the adapter/damper as is. This flange must be located towards the front of the hood. See beside. All installations Using two 1/2” screws, secure the adapter/damper to the top or back of the hood. Seal the adapter/damper to the hood using metal foil duct tape. NOTES: 1. For the best ventilation performance. if a round duct must be used, the duct diameter must be 6” or more. Use a 3%” x 10” to 6” round transition. 2. The wall duct must be well prepared to receive the adapter. Before performing the installation. make sure the adapter fits easily in the duct. 6. INSTALL THE HOOD Run power cable to installation location. Place the hood at its location. Using a pen, mark the position of the screws (smaller part of the embossed keyholes). Remove the hood and install four 1/2” double thread screws at sides locations (A). leaving a 1/8” gap. Place the wire clamp. insert the cable in the hood and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it in position. Make sure the adapter/damper assembly enters the ducting and the damper opens freely. Secure the hood by tightening the screws completely. Install the last 1/2” double thread screw (B) in the remaining embossed hole. 7. CONNECT WIRING A WARNING Risk of electrical shock. Electrical wiring must be done by qualified personnel in accordance with all applicable codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally. Connect cable to range hood wiring using included wire connectors. Connect BLACK to BLACK. WHITE to WHITE and GREEN or BARE WIRE to GREEN ground screw (1). |Do not forget to connect the ground! - 7 - 8. REINSTALL BOTTOM PANEL AND FILTERS 9. FLUORESCENT LAMPS /h WARNING |This hood has fluorescent lamps containing mercury. Dispose of appropriately, according to local laws and requirements. | This range hood must use compact fluorescent lamps (120 V, 13 W, PLC13, 2700 K with G24q-1 base) (included). NOTE: The range hood is shipped with both fluorescent lamps packed behind the light diffuser. 1. To access fluorescent lamps, remove the light diffuser by pushing on its both tabs and pulling it down. 2. To install the fluorescent lamps,...

Este manual também é adequado para os modelos :
Fans - ESB10 (3.12 mb)
Fans - ESC270 (3.12 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias