Log:
Assessments - 3, GPA: 4.7 ( )

Instruções de Operação Napoleon Fireplaces, Modelo GDIZC-N

Fabricante : Napoleon Fireplaces
Arquivo Tamanho: 744.08 kb
Arquivo Nome : 7badcf05-5c9a-fff4-51c7-1205cd40173b.pdf
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :

Facilidade de uso


Smoke shelves, shields and baffles may be removed if at tached by mechanical fasteners. The ventilation openings in the fireplace may be obstructed by the backer plates, aluminium trim etc. but these parts are not to be applied so as to have an airtight seal. 36" 15 1/2" 25" 10 9/16" 5 ." AIR INLET EXHAUST 4 15/16" 15 1/2" 11 5/8" 7 3/8" 3"O 44 7/8" 36 1/2" 4 SIDED BACKER PLATE ALUMINUM TRIM 3 & 4 SIDED BACKER PLATES - SIDE VIEWS 4 SIDED BACKER PLATE - FRONT VIEW W415-0223 / E / 03.05.09 6 W415-0223 / E / 03.05.09 2" OVERLAP EXHAUST SEALANT HI-TEMP INTAKE VENT CONNECTION ASSEMBLY Move the insert close to its fi nal position inside the woodburning fi replace. This unit is equipped with 6 levelling screws located as follows: two are on either side of the circulation blower on the rear panel; four are located front and back on either side beneath the log support. Level using four of the levelling screws. See Figure 1a. Levelling the unit will eliminate rocking or excessive noise when the fan is in operation. Once the unit is level, move it partially into place within the fi replace to allow for all connections to be made. It is not practical to level the insert once the it has been installed. Determine the required depth prior to installing the unit and adjust the four levelling screws accordingly. Chimney installation must conform to both national and local code requirements. The chimney must be lined with one 2" or 3" diameter liner for intake and one 3" diameter liner for exhaust. The minimum and maximum vent lengths are 10 and 35 feet respectively. Recommended Napoleon kits come in 3 lengths: While the liners must be continuous from the fi replace to the terminal, to achieve the needed length, they may be coupled, using an aluminium coupler, provided installation is sealed & secured. We recommend that exhaust vents that pass through unheated spaces, such as a garage or attic, be wrapped in a protective sleeve to minimize condensation and reverse fl ow symptoms. See Trouble Shooting for details. This unit is approved for use with a 2" liner for air intake and a 3" liner for exhaust. For best performance, however, it is recommended to use two 3" liners. If a 2" liner is used for the intake, it is necessary to adjust the primary air shutter. See "Air Shutter Settings" on page 11. 1. OUTSIDE: Slip one end of a liner a minimum of 2" over one of the collars of the terminal. Secure using 3 screws. Then seal the joint and screw heads with high temperature sealant. Repeat with the other liner. NOTE: We recommend that the other end of the exhaust liner be marked to eliminate the exhaust liner being connected to the intake collar at the unit. FIGURE 3 4. Detach the two screws from the back of the fi rebox and remove the panel, as illustrated. 5. Reaching in through the insert, manoeuvre the vent connection assembly through the openings in the fi rebox top, taking care not to damage the gasket. In case of a low ceiling fi replace, the extension should be removed and reinstalled after the vent connection is secured to the fi rebox. Attach the restrictor plate to the centre stud and secure the assembly using the three studs and .-20 hex nuts. INSERT VENT CONNECTION CHIMNEY CONNECTION FIGURE 4 FIGURE5a-b 1-2" & 1-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST & 2-3" TO 2" REDUCER: GDI-2320KT VENT KIT 20FT GDI-2325KT VENT KIT 25FT GDI-2335KT VENT KIT 35FT 2-3" DOUBLE PLY ALUMINUM LINER-INLET AND EXHAUST: GDI-320KT VENT KIT 20FT GDI-325KT VENT KIT 25 FT GDI-335KT VENT KIT 35 FT 2. Gently stretch the liners to the required lengths and insert into the chimney. Place the terminal onto the top of the chimney cap and fi t the fl ashing plate to suit. Make weather tight by sealing with caulking (not supplied) and fasten to the chimney with screws and plugs (not supplied) 3. INSIDE: Attach and secure the fl ex liners to the vent connection assembly using the same procedure as before, ensuring that the marked exhaust liner is attached to the exhaust collar. EXHAUST COLLAR LABELED INTAKE OVERLAP SEALANT HI-TEMP FLASHING PLATE 2" TERMINAL GDI-223 FIGURE 2 RESTRICTOR PLATE STUDS VENT CONNECTOR EXTENSION 7 W415-0223 / E / 03.05.09 For ease of accessibility, an optional remote wall switch or millivolt thermostat may be installed in a convenient location. Route 2-strand solid core millivolt wire from the gas fi replace insert to the wall switch / millivolt thermostat. The recommended maximum lead length depends on the wire size: WIRE SIZE MAX. LENGTH 14gauge 100 feet 16gauge 60 feet 18gauge 40 feet Do not connect either the wall switch, thermostat or gas valve to electricity (110 VOLTS). To adjust the trim: If the mitre is out of alignment, open each side and loosen the two screws at either side trim hinge. Slide the trim up or down to adjust and re-tighten screws. There is also a very slight in/out adjustment that can be made. Note: Since the side panels open and close, to access the controls, a gap is necessary at the mitre joint. The...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias