Instruções de Operação Carrier, Modelo AIR-COOLED CONDENSER UNITS 09BY006-024

Fabricante : Carrier
Arquivo Tamanho: 314.76 kb
Arquivo Nome : 09by-2si.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


Complete Pre-Installation Checks ..1 Step 2 . Rig and Place Unit ................7 • RIGGING • PLACING THE UNIT • VIBRATION ISOLATION • POSITIONING THE 09BY UNIT • VERTICAL DISCHARGE Step 3 . Install Accessory Low-Ambient Kit or Inlet Filter Kit (If Required) ................8 Step 4 . Install Rain Drain .................8 Step 5 . Complete Refrigerant Piping .......8 • GENERAL • REFRIGERANT LINE SIZING • PRESSURE RELIEF • REFRIGERANT RECEIVER • LIQUID LIFT • SWEAT CONNECTIONS • FIELD PIPING • MANIFOLDING CIRCUITS • CHECK VALVE • SERVICE VALVES Step 6 . Ductwork ........................10 • CONDENSER AIR DUCT INSULATION Step 7 . Insulate the Unit .................11 Step 8 . Complete Electrical Connections ..11 • GENERAL • MAIN POWER WIRING • CONTROL CIRCUIT POWER WIRING • GENERAL WIRING NOTES START-UP .................................13 System Evacuation and Dehydration ........13 Charging Procedure .......................13 Check Operation of Condenser Fan Motor Controls and Rotation of Fans ...........13 Adjust Fan Speed .........................13 SERVICE ................................. 13-15 Cleaning Condenser Coils .................13 Lubrication ................................13 Condenser Fan Adjustment ................13 • TO CHANGE FAN SPEED • PULLEY ALIGNMENT • BELT TENSION ADJUSTMENT • TO CHANGE FAN WHEEL • TO REPLACE FAN BEARING MAINTENANCE ............................15 Cleaning ..................................15 Inspection .................................15 Air Filters .................................15 Condensate Drain .........................15 TROUBLESHOOTING ......................16 START-UP CHECKLIST ................ CL-1,CL-2 SAFETY CONSIDERATIONS Installing, starting up, and servicing air-conditioning equipment can be hazardous due to system pressures, electrical components, and equipment location. Only trained, qualified installers and service mechanics should install, start-up, and service this 09BY equipment (Fig. 1). When working on the equipment, observe precautions in the literature and on tags, stickers, and labels attached to the equipment. Follow all safety codes. Wear safety glasses and work gloves. Keep quenching cloth and fire extinguisher nearby when brazing. Use care in handling, rigging, and setting bulky equipment. ELECTRICSHOCKHAZARDSeparatepowersources(mainandcontrolpowercircuits)areusedfortheseunits.Besurebothmainandcontrolpowercircuitsaredisconnectedbeforeservicing. GENERAL The 09BY air-cooled condenser is a remote air-cooled condenser designed to be used with the 50BZ vertical packaged units. See Table 1. Airflow is horizontal, both into and out from the same face of the unit. The unit is designed to be mounted indoors in a window, through the wall in high-rise buildings, or on the wall on the building exterior. See Fig. 2 for typical applications. Ductwork is not needed, but may be added easily if required by the application. Airflow is provided by centrifugal fans with an adjustable belt drive to meet varying static requirements. Units may also be matched with other compressor and evaporator combinations. Contact your local representative for more details. Check space requirements, service clearances, floor strength, location of piping, size of power supply, and location of duct- work (if used) before installing. See Fig. 3 for unit dimensions and Table 2 for unit operating weights. INSTALLATION Step 1 — Complete Pre-Installation Checks — Examine unit for damage incurred during shipment. File claim immediately with transit company if damage is found. Check the shipment for completeness. Verify that the nameplate electrical requirements match the available power supply. Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Book 2 4 PC 111 Catalog No. 530-969 Printed in U.S.A. Form 09BY-2SI Pg 1 9-96 Replaces: 09BY-1SI Tab 4a 4a Fig. 1 — 09BY Unit (008-014 Shown) 2 HANGER TO OUTSIDE RODS 09BY DISCHARGE DUCT INLET DUCT INSULATE IF THROUGH CONDITIONED SPACE TO RAIN DRAIN (REQUIRED IF RAIN WILL ENTER UNIT) TO REFRIGERANT PIPING COMPRESSOR/ EVAPORATOR UNIT 09BY IN REMOTE APPLICATION WITH DUCTWORK (Shown Suspended from Ceiling) OUT IN OUTSIDE WALL HEIGHT AS REQUIRED FOR WINDOW OR WALL OPENING POWER CONNECTION WALL LOUVERS (FIELD SUPPLIED)50BZ 09BY TO RAIN DRAIN (REQUIRED IF RAIN WILL ENTER UNIT) FLOOR LEGEND STAND* Refrigerant Connection Field-Supplied Refrigerant Piping 09BY DIRECT CONNECTION TO 50BZ UNIT *Field-Supplied Floor Stand (Height to Match Wall Opening). Fig. 2 — Mounting Applications 3 09BY DIMENSIONS (English) 09BY DIMENSIONS (SI) DIMENSION 006 (Ft-in.) 008 (Ft-in.) 012 (Ft-in.) 014 (Ft-in.) 016,024 (Ft-in.) A 2-111.2 3-613.16 3-613.16 3-613.16 5-0 B 1-711.16 1-115.8 1-115.8 1-115.8 2-97.16 C 4-07.16 4-8 5-31.2 5-11 7-69.16 D 1-111.4 2-39.16 2-39.16 2-39.16 2-11 E 0-111.8 1-2 1-2 1-2 1-73.4 F 0-63.16 0-57.8 0-711.16 0-117.16 1-1111.16 G 1-15.16 1-35.8 1-47.8 ...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias