Log:
Assessments - 1, GPA: 4 ( )

Instruções de Operação CDA, Modelo EVPK9

Fabricante : CDA
Arquivo Tamanho: 500.9 kb
Arquivo Nome : 356788f9-20a5-438c-baa4-72ffbe78390e.pdf
Língua de Ensino: en
Ir para baixar



Facilidade de uso


3. Then lower the grease filter to remove it completely. To replace the grease filters, repeat the steps in reverse. Please note: Cleaning the grease filter in the dishwasher may lead to discolouration. This is normal and does not constitute a fault with the appliance. Changing the charcoal filter (re-circulating only) When the display flashes alternating the speed selected with the letter F, the charcoal filters must be replaced. After the charcoal filter has been replaced, the electronic memory must be reset by touching key A for approximately five seconds, until the letter F stops flashing. To attach a new charcoal filter, first open the cover panels and the filters as described above. Then offer up the charcoal filter into the frame as shown in figure 3. Repeat with the other charcoal filter. Then replace the grease filters and cover panels. Fig. 2 Fig. 3 3Care and Maintenance IMPORTANT : DO NOT PERFORM MAINTENANCE OR CLEANING OF THE EXTRACTOR WITHOUT FIRST SWITCHING OFF THE ELECTRICITY SUPPLY. Cleaning You should use a nonabrasive cleaner. Any abrasive cleaner (including Cif) will scratch the surface and could erase the control panel markings. You can clean your extractor effectively by simply using a dilute solution of water and mild detergent and drying to a shine with a clean cloth. Cleaning the grease filter The grease filters should be kept clean to minimise the risk of fire. When the display flashes alternating the speed selected with the letter A, or at least once a month, you should remove and clean the grease filters with hot soapy water. You can also wash the grease filters in a dishwasher, ensuring that you place it in an upright position to prevent damage from other items in the dishwasher. After rinsing and drying, replace the filters. After the grease filters has been replaced, the electronic memory must be reset by touching key A for approximately five seconds, until the letter A stops flashing. To remove the grease filters follow the steps below: 1. Open the stainless steel cover panels by pulling them downward from the centre. They will hinge to the sides. 2. Pull open the handle on the grease filter as shown in fig 2. It will release at the handle side. 3. Then lower the grease filter to remove it completely. To replace the grease filters, repeat the steps in reverse. Please note: Cleaning the grease filter in the dishwasher may lead to discolouration. This is normal and does not constitute a fault with the appliance. Changing the charcoal filter (re-circulating only) When the display flashes alternating the speed selected with the letter F, the charcoal filters must be replaced. After the charcoal filter has been replaced, the electronic memory must be reset by touching key A for approximately five seconds, until the letter F stops flashing. To attach a new charcoal filter, first open the cover panels and the filters as described above. Then offer up the charcoal filter into the frame as shown in figure 3. Repeat with the other charcoal filter. Then replace the grease filters and cover panels. Fig. 2 Fig. 3 4Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. Using a flat blade screwdriver, carefully prise off the lamp cover as shown in figure 5. Remove the bulb and replace with a 12V 20W halogen light bulb. Finally, replace the light bulb cover. Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights. The light is designed for use during cooking and not for general room illumination. Extended use of the light can reduce the life span of the bulb. Bulb replacement is not covered by the guarantee. Only use bulbs recommended for your extractor. Do not fit bulbs of a higher power rating. Bulbs of a lower power rating may be adequate for use, generally last longer and use less energy. CDFig. 5 4Changing the Light DO NOT CHANGE THE LIGHT BULB IMMEDIATELY AFTER USE AS THE BULB WILL BE HOT. ALLOW IT TO COOL BEFORE REMOVING IT. Using a flat blade screwdriver, carefully prise off the lamp cover as shown in figure 5. Remove the bulb and replace with a 12V 20W halogen light bulb. Finally, replace the light bulb cover. Do not touch bulbs or adjacent areas during or straight after prolonged use of the lights. The light is designed for use during cooking and not for general room illumination. Extended use of the light can reduce the life span of the bulb. Bulb replacement is not covered by the guarantee. Only use bulbs recommended for your extractor. Do not fit bulbs of a higher power rating. Bulbs of a lower power rating may be adequate for use, generally last longer and use less energy. CDFig. 5 5DOUBLE POLE SWITCHED FUSED SPUR OUTLET USE A 3 AMP FUSE Mains Electricity Connection THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON, USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE. We recommend that the appliance is conn...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias