Log:
Assessments - 3, GPA: 4 ( )

Instruções de Operação Miele, Modelo DA 420 V EXT

Fabricante : Miele
Arquivo Tamanho: 832.63 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :
Hoods - DA 420 V EXT (891.54 kb)ru

Facilidade de uso


If more than one appliance is fitted beneath the cooker hood and they have different minimum safety distances to the cooker hood, select the greater distance. If the distance falls below the recommended safety distance when the canopy is lowered, the max. interval it is allowed to be lowered must be re-set during installation. See the installation instructions for further advice. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders’ merchants. The appliance must not be connected to a chimney or vent flue which is in use. Neither should it be connected to ducting which ventilates rooms with fireplaces. If exhaust air is to be extracted into a chimney or ventilation duct no longer used for other purposes, seek professional advice. Warning and Safety instructions Using at the same time as other heating appliances that depend on the air from the room Warning - danger of toxic fumes Great care should be taken when using the cooker hood at the same time and in the same room or area of the house as another heating appliance which depends on the air in the room. Such appliances include gas, oil, wood or coal-fired boilers and heaters, continuous flow or other water heaters, gas hobs, cookers or ovens which draw air in from the room and duct exhaust gases out through a chimney or extraction ducting. When used in extraction mode, with or without an external motor, the appliance draws air in from the room in which it is installed and from neighbouring rooms. If there is insufficient air, an underpressure will occur. The heating appliance may be starved of oxygen, impairing combustion. Harmful gases such as carbon monoxide could be drawn out of the chimney or extraction ducting back into the room, with potentially fatal consequences. In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible. Ventilation can be maintained by air inlets which cannot be blocked, in windows, doors and outside wall vents, or by other technical measures, such as ensuring that the extractor can only be switched on when the heating appliance is switched off or vice-versa. A ventilation brick alone is not generally sufficient to ensure safe ventilation. The overall ventilation condition of the dwelling must be taken into account. If in any doubt, the advice of a competent builder or, for gas, a "Corgi" installer, must be sought. Warning and Safety instructions One of the following technical measures may be necessary to ensure safe operation. – If the only way of ensuring adequate ventilation is via an open window, a window contact switch should be fitted to ensure that the cooker hood can only operate when the window is opened sufficiently. A window contact switch kit is available from good builders’ merchants. Take care when ventilating the room through an open window that ventilation is not impaired by a closed blind or curtain. – The cooker hood can be set up to automatically switch on an air intake fan or open a motorised inlet flap when it is switched on. – The cooker hood can be set up to automatically switch off a heating appliance which also depends on the air from the room when it is switched on. The Miele control module DSM 400 offers the possibility of combining such components with the cooker hood (see "Operation with a control module"). This is available to purchase as an optional extra. If in any doubt, the advice of a competent builder or, for gas, a "Corgi" installer, must be sought. If the hood is being operated in recirculation mode, the above restrictions do not apply. Disposal of your old appliance Before disposing of your old appliance, first make it unusable. This should be done by a competent person. The manufacturer cannot be held liable for damage caused by non-compliance with these Warning and Safety instructions. Modes of operation The cooker hood works with . . . air extraction: The air is drawn in, cleaned by the grease filters and directed outside. The cooker hood is fitted with a non-return flap, which is closed when the cooker hood is switched off. No exchange of room air and outside air can take place. When the cooker hood is switched on, the non-return flap opens for the cooking vapours to be blown directly outside. . . . air recirculation: (Applies to the DA 420 V only. A conversion kit and charcoal filter are required, which are available as optional accessories: see "Technical Data") The air is drawn in and cleaned first by the grease filters and then by a charcoal filter. The cleaned air is then recirculated back into the kitchen through grilles in the top of the cooker hood telescopic tower. Before using the cooker hood in recirculation mode, ensure that the charcoal filter is in place. See "Cleaning and ...

Este manual também é adequado para os modelos :
Fans - DA 420 V (832.63 kb)
Fans - DA 424 V (832.63 kb)
Fans - DA 424 V EXT (832.63 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias