Facilidade de uso
– To ensure free access to work under the ventilation hood, a distance of a minimum of 26" (660 mm) above the electric cooktop is also recommended. – Take the user's body height into consideration when selecting the installation height. Adequate work space at the cooktop and optimal operation of the ventilation system should be ensured. – However, the greater the distance from the cooktop, the less effectively cooking odors are drawn in. – If the top of the hoods telescopic extension piece will be mounted flush to the ceiling, regard the possible unit height when selecting the installation height. Appliance dimensions Drilling diagram To prepare a backing plate, the spacings for the 5 mm screws need to be drilled as shown. * The dimension between the ceiling and the middle bracket may vary depending on the position of the vent cut-out and the power socket. It should be installed as low as possible. If the ventilation hood will be mounted directly to the wall, follow the additional instructions given in the included "Installation diagram". Plywood backing The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ." (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage. (If plywood backing is not needed, proceed to the included "Installation diagram".) To install a plywood backing . Find the studs to the left and right of the mounting location by tapping the wall or using a stud finder. . Mark a vertical cutting line along the center of each stud. CAUTION When cutting or drilling into the wall or ceiling, do not damage electrical wiring and other hidden utilities. . Remove the drywall between the cutting lines and replace it with plywood of a matching thickness (min. ." (13 mm) thick). Tape the joints and refinish the wall. . Proceed to the enclosed "Installation diagram" to complete the installation. . Determine and mark the location of the retaining plate for the canopy as outlined on the "Installation diagram". . Make a cutting line 3" (76 mm) above and 3" (76 mm) below the outline of the retaining plate. Installation Before installation read the information in the "Dimensions" and "Important Safety Instruction" chapters. Under certain conditions, there is a danger of poisonous fumes by when the ventilation system and a furnace drawing interior air run at the same time. Installation instructions The individual installation steps are described in the included Installation diagram. Protective film (stainless steel units) The casing is covered with a protective film to prevent scratching during transport. . Please peel off the film before installing the casing parts. It can be removed without tools. Dismantling If the hood needs to be disassembled, follow the instructions on the "Installation diagram" in the reverse order. A lever is enclosed for easier removal of the chimney extension. . After removing the two screws from the chimney, slide the lever between the chimney and the chimney extension and gently apply pressure to ease the chimney from its hooks. Installation materials Installation 28 Installation . 3 protective shields to prevent scratches to the chimney during installation. . 1 vent collar for use with 6" (150 mm) exhaust ducting. . 1 reducing collar for use with 5" (125 mm) exhaust ducting. . Upper wall bracket for securing the telescopic extension piece . Middle wall bracket for securing the telescopic extension piece . Lower wall bracket for securing the ventilation system . Installation kit for recirculation mode contains diverter, hose and hose clips (optional accessory). 6 Screws5x40mm (S8 wall anchors included in the packaging are not for use in USA / CDN) The screws and wall anchors are suitable for solid brick walls. For other wall constructions, use appropriate materials. Ensure that the wall can support the weight. 2 M 6 locking nuts for securing the motor assembly. 2 Screws 3.9 x 7.5 mm for securing the chimney. 1 Lever for dismantling the chimney. Installation instructions Electrical connection WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is off while installation or repair work is performed. . Verify that the voltage, load and circuit rating information found on the data plate (located behind the grease filters), match the household electrical supply before installing the hood. . Use only with ventila...
Este manual também é adequado para os modelos :Fans - DA 398-5 (1.01 mb)