|
Facilidade de uso
For recirculation make sure that the openings in the extension piece are positioned at the same height as the air outlets in the directional unit of the fan motor. Installation The paper protective sheet protects the Fitting the tower extension piece from being scratched Before fitting remove the protective when the tower is being fitted. It is foil. removed when fitting is complete. Fold the protective sheet at the top. Remove the protective foil from around the sticking points. Stick the protective sheet to the extension piece so that it is smooth at the sides and flush at the bottom. A protective cardboard sheet protects the tower from accidental scratching during fitting. Remove the protective foil from around the sticking points. Attach the protective sheet to the front of the tower so that it protrudes slightly below the bottom edge. Installation Hold the main tower gently apart and fit it over the extension piece. Then slide the tower down approx. 2 cm into the canopy. Adjust the tower. Remove the protective sheets. Now secure the tower on both sides with two 3.9 x 7.5 mm screws. Remove the protective foil from the canopy. Before using the appliance for the first time take the grease filter out and remove the protective foil from the filter frame. Then replace the filter. Connection for air extraction Danger of toxic fumes. Please heed the "Warning and Safety instructions" to avoid the danger of toxic fumes. The cooker hood should be installed according to local building regulations. Seek approval from the building inspector where necessary. – All ducting, pipework and fittings must be of non-flammable material. – The extraction ducting should be as short and straight as possible. – To ensure efficient air extraction the diameter of the exhaust ducting should not be less than 150 mm. If exhaust ducting with a diameter of less than 150 mm or flat ducting were to be used, the noise level of the cooker hood would increase and extraction would be less efficient. Only reduce the diameter of the ducting if absolutely necessary, e.g. where narrower ducting has already been installed. – Only use wide radius bends. Tight bends reduce the air throughput of the cooker hood. – Only use smooth pipes or flexible hoses made from non-flammable materials for extraction connection. – Where ducting is horizontal it must be laid to slope away at at least 1 cm per metre. This is to ensure that condensate cannot drain back into the cooker hood. – If the exhaust air is to be ducted into the open air, the installation of a telescopic wall vent is recommended. –If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue. Connection for air extraction Important: If the exhaust ducting is to run through rooms, ceiling space etc. where there may be great variations in temperature between the different areas, the problem of sweating or condensation will need to be addressed. The exhaust ducting will need to be suitably insulated. Condensate trap In addition to insulating the exhaust ducting, we recommend that a suitable condensate trap is also installed to collect and evaporate any condensate which may occur. When installing a condensate trap ensure that it is positioned vertically and if possible directly above the exhaust connection. Electrical connection All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with national and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. The manufacturer can not be held responsible for unauthorised work. Ensure power is not supplied to the appliance while installation or repair work is being carried out. U.K., IRL, NZ, ZA: The cooker hood is supplied for connection to an a.c. 230 V single phase 50 Hz supply. AUS: The cooker hood is supplied for connection to an a.c. single phase 240 V, 50 Hz supply. The voltage, rated load and fusing are given on the data plate. This is visible when the grease filters have been removed. Ensure that these match the household mains supply. For U.K.: Connection should be made either by a double pole fused spur connection unit, or a fused plug and a suitable switched socket. The On-Off switch should be easily accessible after the appliance has been built in. When switched off there must be an all- pole contact gap of 3 mm in the switch (including switch, fuses and relays according to EN 60 335). If the socket is not accessible after installation (depending on country) an additional means of disconnection must be provided for all poles. For extra safety it is advisable to install a residual current device (RCD) with a trip current of 30 mA (in accordance with DIN VDE 0664, VDE 0100 Section 739). Do not connect via an extension lead. Important UK If the appliance is fitted with a non-rewireable plug (BS 1363 UK) and the socket outlets are not suitable for the plug supplied, or if the existing plug ne...
Este manual também é adequado para os modelos :Fans - DA 216-2 (914.86 kb)
Fans - DA 216-2 EXT (914.86 kb)
Fans - DA 217-2 (914.86 kb)
Fans - DA 219-2 (914.86 kb)