Log:
Assessments - 2, GPA: 3.5 ( )

Instruções de Operação Windster, Modelo WS-55 SERIES

Fabricante : Windster
Arquivo Tamanho: 474.68 kb
Arquivo Nome : WS-55.pdf
Língua de Ensino: en
Ir para baixar



por este dispositivo também tem outras instruções :
Fans - WS-55 SERIES (384.88 kb)

Facilidade de uso


DUCTING This style of range must be vented via ducting to the outside of the house. Follow general rules when ducting the hood: Use correct size of ducting (6" or 7” round ), do not reduce size of ducting, make all turns gradual, no short corners. If ducting ran will be longer than 10 feet enlarge duct by at least 1" inch diameter after each 10 feet. Tape all joints in ducting and all gasketed openings on hood for a tight seal. For round ducting from the top: For the gray plastic (included) over the circular opening on top in order to provide a tight seal for ducting to attach to. The GRAY ring is designed to fit either 6“ or 7” ducting. 11 12CorrectionSymptomFan are not operatable. Illuminating lightdoes not workHood vibrates. A. Checkpower source to see if it isnormal. B. Check power inlet plug to see if it isplugged firmly into it's socket. A. Disconnect the power source. B. Check light, replace it with a newone if it is burned out. A. Check for damaged vanes. B. Check if exhaust duct is secured. N. TROUBLESHOOTINGSNOTE : Any faults with this unit should only be attended to by a qualified technician. P. CIRCUIT DIAGRAM(4+4uf 350V) 50/60 HZ4u4u SWITCHBLACKBLUEREDBLUEREDWHITEACGREENEARTH GROUNDBLACKLAMPWHITEWHITEYELLOWBLUEYELLOWREDBLUEBLUEYELLOWREDBLUEMOTORMOTORCAPACITOR12CorrectionSymptomFan are not operatable. Illuminating lightdoes not workHood vibrates. A. Checkpower source to see if it isnormal. B. Check power inlet plug to see if it isplugged firmly into it's socket. A. Disconnect the power source. B. Check light, replace it with a newone if it is burned out. A. Check for damaged vanes. B. Check if exhaust duct is secured. N. TROUBLESHOOTINGSNOTE : Any faults with this unit should only be attended to by a qualified technician. P. CIRCUIT DIAGRAM(4+4uf 350V) 50/60 HZ4u4u SWITCHBLACKBLUEREDBLUEREDWHITEACGREENEARTH GROUNDBLACKLAMPWHITEWHITEYELLOWBLUEYELLOWREDBLUEBLUEYELLOWREDBLUEMOTORMOTORCAPACITOR Q. Parts Layout Diagram 13 Q. PARTS LAYOUT DIAGRAM 1 2 5 7 8 9 10 11 21 4 6 3 22 23 24 25 26 27 28 17 18 19 20 15 16 12 13 14 PARTS LIST No. Description Parts no. Per hood 1 Hood casing 55-01 1 2 Air chamber 55-02 1 3 Bottom board 55-03 1 4 Wire box 55-04 1 5 Motor housing 55-05 2 6 Oil collector (large) 55-06 2 7 Motor (L/R) 55-07 2 8 Fan (L/R) 55-08 2 9 Oil tunnel 55-09 2 10 Safety mesh (L/R) 55-10 2 11 Oil collector (small) 55-11 2 12 Exhaust pipe connector 55-12 1 13 Power cord 55-13 1 14 Earth 55-14 1 15 Light switch 55-15 1 16 Speed switch 55-16 2 17 Screw 55-17 3 18 Lamp shade 55-18 1 19 Washer 55-19 1 20 Screw 55-20 2 21 Capacitor 55-21 1 22 Wire connector (large) 55-22 1 23 Wire connector (small) 55-23 1 24 Light bulb 55-24 1 25 Light bulb socket 55-25 1 26 Cord bushing 55-26 1 27 Wire box cover (small) 55-27 1 28 Wire box cover (large) 55-28 1 * Specifications subject to change without notice. 14 S. Size 15 S. SIZE 20-7/8” 6-1/2” 30” (36”)(42”) (1). Mount the recirculation kit to the bottom of the cabinet. (Screws not included with recirculation kit) (2). After securing the recirclation kit to the bottom of the cabinet, make sure to run the path for the electrical power cord. (3). Before mounting the range hood, be sure to connect the electrical power cord. Mount the range hood using the screws porvided to the bottom (4 sides) of the recirculation kit. (30” - 5 pcs screws) (36”/42”/48” - 9 pcs screws) (4). Before powering the unit, make sure all screws and power cord have been properly connected. After all connections have been secured your recirculating range hood is ready for use. Note: Before mounting the range hood and recirculation kit, please must refer the following from the manual. 1. P.5 “E. Preparing the Range Hood” remove the top electrical knockout (recirculation kit is same step) 2. P.7 ” . 3. P.8 “H. ”. G. Providing electrical power” Mounting Range Hood To Cabinet R. Recirculation Kit Installation (optional) (1) (2) (3) (4) Limited Warranty Windster Hoods Inc. warrants this product against defects in material or workmanship as follows: 1) Labor: For a period of one (1) year from the date of purchase, if this product is determined to be defective, Windster will repair or replace the product, at its option, at no charge. After the warranty period, you must pay for all labor charges. During the “labor” warranty period there will be no charge for labor. 2) Parts: In addition, Windster will supply, at no charge, new or rebuilt replacements in exchange for defective parts for a period of two (2) years. After the warranty period, you must pay for all parts costs. During the “parts” warranty period, there will be no charge for parts You must carry-in or mail-in your product during the warranty period. This warranty only applies to products purchased and serviced in the United States or Canada. What Is Not Covered By These Warranties: 1) Conditions and damages resulting from any of the following: . Improper installation, delivery, or maintenance. . Any repair, modification, alteration or adjust...


Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias