|
Facilidade de uso
TIMER For your convenience, Honeywell provides a timer control that can fit a wide variety of needs, for example, exhaust humid air from the bathroom or kitchen (see the installation guide for selection and part numbers). WALL SWITCH A wall switch can also be used to switch your ventilator fan speed to high. The fan will run at high speed until the wall switch is turned off. When any remote device is activated the ventilator will run at high speed. All remote devices must be in the off position to return the fan to the speed manually selected on the rotary fan speed control knob. Getting the most from your Fresh Air Ventilation System HOW MUCH VENTILATION DO I NEED? During the seasons that your windows and doors are closed (winter and summer if you have air conditioning), the ventilator should operate continuously when the home is occupied, and either continuously or intermittently when not occupied. For most installations, the ventilator will normally be set to operate continuously on low speed with the option of going to high speed as the need arises. For example, if you are entertaining and there is a large number of people present (some may be smoking), the ventilator should be switched to high speed. YOUR VENTILATOR MAY BE SET TO HIGH SPEED BY: 1. selecting the highest speed on the ventilator or 2. if the system includes an optional remote control, switch it to the ON position. NOTE: To set the dehumidistat, refer to the previous section of this booklet. To operate other remote devices, refer to the device owner.s manual. 69-0994.4 6 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS WARNING Electrical Shock Hazard. Can cause personal injury or equipment damage. Disconnect power supply before performing maintenance. The Perfect Window. Fresh Air Ventilation System must be maintained on a regular basis for best efficiency. Honeywell recommends that the ventilator be cleaned and checked at least twice a year, preferably at the beginning of each heating and cooling season. Check and Clean EXTERIOR HOODS Exterior hoods should be inspected at least once a month. Be sure exhaust and fresh air supply hoods are not blocked up or restricted by leaves, grass or snow. In winter, it is especially important to make sure snow is not blocking the hoods or that frost has not built up on the wire mesh (bird screen). WARNING Can cause personal injury or equipment damage. Hood blockage can cause a change of pressure in building which can lead to possible spillage from combustible appliances. AIR FILTERS Air filters should be cleaned twice a year. The standard filters supplied with your ventilator are removable and washable. 1. Open access door and slide out core. Refer to Core Maintenance section for cleaning instructions. 2. Remove filter clip. 3. Remove filters from the core and rinse with water or a combination of soap and water. Do not clean in a dishwasher. 4. After cleaning, place filters (wet or dry) back in their position and reattach the retaining clip. 7 69-0994.4 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Clean the core twice each year. FILTER CLIP FILTER 1. Open the access door and carefully grip the ends of the core and pull evenly outward. The core can be snug, but it will slide out of the cabinet. NOTE: Do not handle the fins because damage can occur. 2. Once out of the cabinet, remove the filters (refer to Air Filter Maintenance section). 3. Wash the core in warm soapy water.do not use a dishwasher. 4. Reinstall the clean filters. 5. Reinstall the clean core. NOTE: Do not detach the foam on the ends of the core or the core label, water does not damage them. To install the clean core: 1. First mount the bottom core guide into the bottom H channel. 2. Mount either side core guide, followed by the other side. 3. Mount the top core guide into the top H channel. 4. With all four comers in place and the core straight and even, push on the core center until the core slides to the back of the cabinet. NOTE: The core will appear to stick out from the cabinet approximately 1/8 in. (3mm). It is designed this way, so that the access door will fit tightly against the core. MANUAL CONTROL MODEL CORE GUIDE M11702A 69-0994.4 8 HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS HR150 AND HR200 Perfect Window. FRESH AIR VENTILATION SYSTEMS Clean the drain line once a year. 1. Inspect the drain line, drain spout and P trap for blockage, mold or kinks. 2. Flush with warm soapy water and replace if worn or bent, or if it can not be clean...
Este manual também é adequado para os modelos :Fans - PERFECT WINDOW HR150 (233.88 kb)
Fans - PERFECT WINDOW HR150 (233.88 kb)
Fans - PERFECT WINDOW HR200 (233.88 kb)