Log:
Assessments - 2, GPA: 4.5 ( )

Instruções de Operação GE, Modelo GE Monogram ZVC36

Fabricante : GE
Arquivo Tamanho: 3.53 mb
Arquivo Nome : 4a7870b9-ee03-450d-ab89-5c565a0ecfbb.pdf
Língua de Ensino: enesfr
Ir para baixar



Facilidade de uso


x 12. 90° flat elbow 102 ft. 8. round to 3-1/4. x 12. transition 2 ft. 3-1/4. x 12. to 8. round transition 5 ft. 8. round to 3-1/4. x 12. transition 90° elbow 6 ft. 3-1/4. x 12. to 8. round transition 90° elbow 13 ft. Round wall cap with damper 32 ft. 3-1/4. x 12. wall cap with damper 75 ft. Round roof cap 44 ft. Total Duct Run *Actual length of straight duct plus duct fitting equivalent. Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood. 10 11 Installation Preparation TOOLS AND MATERIALS REQUIRED (NOT SUPPLIED) Pencil and tape measure Wire cutter/stripper Step ladder Wire nuts Phillips and flat-blade screwdrivers Strain relief Spirit level Flashlight Safety glasses 8. ducting and caps as needed Aluminized duct tape 1/4. pivoting hex socket REMOVE THE PACKAGING CAUTION: Wear gloves to protect against sharp edges. CAUTION: LIFT THE INSERT SLEEVE OUT OF THE BOX BY GRASPING THE SIDES. 1. Open hood carton. 2. Remove the liner, foam and cardboard. 3. Remove the tape securing the filters to the insert sleeve, lift the tabs and remove the filters. 4. Unscrew the 5 nuts securing the damper vent plate assembly, and remove it from the insert sleeve. Set the 5 nuts and the damper vent plate assembly aside, as you will be re-installing it later in the installation process. 5. Remove the screws attaching the insert sleeve to the mounting board. Discard the screws. 6. Grasp the insert sleeve by the outside edges, and lift straight up and out of the carton. NOTE: Do not lift the insert sleeve by the blower motor. 7. Remove and properly discard the plastic wrapping. 8. Remove the parts box and other packaging. Electric drill and appropriate bits 1. conduit (for remote mounting only) Gloves 3/8. socket/ nut driver Knife Plumb line Silicone Needle-nose pliers Tin snips 12 Installation Preparation PARTS PROVIDED Locate the parts packed with the hood. CHECK INSTALLATION HARDWARE Count screws/ components. Screws shown actual size. Hood liner (packed in separate carton) Blanking plate for remote control opening* 6 wood screws for hood liner 8 wood screws for insert sleeve 5 nuts for damper plate assembly (not located in hardware bag–you must save nuts when you remove damper plate from inset hood while unpacking parts) Blower motor (30. and 36. Wide Models) Insert sleeve Filters 2 wing nuts with lock washers for blower motor *NOTE: To be used on custom hood when controls are remotely mounted. Damper plate Control wall bracket Control mounting plate 2 mounting plate screws 30 ft. of 4-wire cord (straight-pinned) with connector/converter NOTE: Not for telecommunications (telephone) network. 2 wall bracket screws Dual blower motor (42. and 48. Wide Models) Control mounting bracket 6 insert sleeve chassis plugs, 1 (optional) house wire hole plug, 2 rubber grommets, 4 insert sleeve washers REMOTE MOUNTING OF THE CONTROL (WIRED) Connector/ Converter Wall Installation Preparation DUCTWORK, WIRING LOCATIONS Determine the exact location of the insert sleeve. Mark the exact centerline location. The ceiling structure must be capable of supporting the weight of the insert sleeve (approximately 100 pounds), the canopy itself, any mounting hardware and any inadvertent user contact loads. • Measure from the top of the cooking surface to the bottom edge of the insert sleeve. Add insert sleeve installation height. Mark that location. • Use a level to draw a straight horizontal pencil line on the wall. NOTE: House duct should drop to 11-1/2. above bottom edge of insert sleeve. Location of house duct is important because it must align with vent of damper plate assembly. Ceiling ducting: If ductwork will vent straight up to the ceiling: • Use a level to draw a centerline straight up to the ceiling. • On the ceiling, measure 5-1/2. from the back wall to the centerline of an 8-1/2. hole. Rear Wall Ducting: (See important note.) If ductwork will vent to the rear: • Use a level to draw a centerline straight up to the ceiling. • Measure at least 22-1/2. above the pencil line that indicates the bottom installation height, to the centerline of an 8-1/2. dia. duct hole. (Hole may be elongated for duct elbow.) HOUSE WIRING LOCATION: • The junction box is located inside the top left side of the hood. • Wiring should enter the back wall at least 15. above the bottom of the insert sleeve, and within 6. of the left side of the centerline. 22-1/2. above pencil line indicatingbottom of hood 5-1/2. from rear wall to centerline *30. Minimum required *36. Maximum recommended installation height from cooking surface 36. from floor to countertop *30. Minimum required *36. Maximum recommended installation height from cooking surface 36. from floor to countertop Front viewSide view 11-1/2. 4. liner height 11-1/2. 22-1/2. above pencil line indicating bottom of hood 4. liner height IMPORTANT NOTE: If you are planning to vent through the rear wall,...

Este manual também é adequado para os modelos :
Fans - GE Monogram ZVC30 (3.53 mb)
Fans - GE Monogram ZVC42 (3.53 mb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias