Log:
Assessments - 3, GPA: 3.7 ( )

Instruções de Operação Emerson, Modelo CF2455BS00

Fabricante : Emerson
Arquivo Tamanho: 277.5 kb
Arquivo Nome :
Língua de Ensino: en
Ir para baixar



Facilidade de uso


b. Connect the black fan wire to the black receiver wire (TO MOTOR L). c. Connect the black supply wire to the black/white receiver wire (AC IN L). d. Cut off the ends of the blue and yellow receiver wires and strip back insulation 1/2-inch from the ends of the wires. e. Connect the blue fan wire to the blue receiver wire (BOTTOM LIGHT). f. Connect the yellow fan wire to the yellow receiver wire (UPPER LIGHT). g. Connect the green ground wires from the hanger bracket and the hanger ball to the supply ground wire (bare or green). OUTLET BOX BLACK SUPPLY WIRE BLACK/WHITE RECEIVER WIRE BLACK FAN WIRE BLUE FAN WIRE BLUE RECEIVER WIRE YELLOW FAN WIRE YELLOW RECEIVER WIRE CEILING COVER WHITE RECEIVER WIRE WHITE FAN WIRE WIRE CONNECTOR RECEIVER WHITE SUPPLY HANGER BALL GROUND WIRE HANGER BRACKET GROUND WIRE HANGER BRACKET BLACK RECEIVER WIRE OPEN PORTION OF RECEIVER HERE 8 BLUE RECEIVER WIRE YELLOW RECEIVER WIRE BLUE FAN WIRE DOWNROD BLACK FAN WIRE SW105 RECEIVER WHITE FAN WIRE WHITE RECEIVER WIRE BLACK RECEIVER WIRE YELLOW FAN WIRE BLACK/WHITE RECEIVER WIRE BLACK SUPPLY WIRE WHITE SUPPLY WIRE BLUE RECEIVER WIRE YELLOW RECEIVER WIRE BLUE FAN WIRE DOWNROD BLACK FAN WIRE SW105 RECEIVER WHITE FAN WIRE WHITE RECEIVER WIRE BLACK RECEIVER WIRE YELLOW FAN WIRE BLACK/WHITE RECEIVER WIRE BLACK SUPPLY WIRE WHITE SUPPLY WIRE Figure 15 WARNING ! Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result. 1-1/4" THREADED STUDS (2) HANGER BRACKET OUTLET BOX RECEIVER 4. After connections have been made, separate the white and green wires from the black, blue and yellow wires. 5. Carefully turn the wires upward and insert them up through the open side of the hanger bracket and CEILING COVER into the outlet box. Push the green and white wires into one side of the outlet box; push the black, blue and yellow wires into the other side of the outlet Figure 16 box. Final Assembly 1. Screw the two 1-1/4” threaded studs (supplied) into the tapped holes in the hanger bracket (Figure 16). 2. Lift the ceiling cover up to the threaded studs and CEILING COVER turn until studs protrude through the holes in the 1-1/4" ceiling cover (Figure 17). THREADED STUD 3. Secure the ceiling cover in place by installing two lockwashers and two knurled knobs (supplied) (Figure 17). Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the Figure 17 downrod. KNURLED KNOB LOCKWASHER 4. Screw in three 40-watt (maximum) candelabra base lamps in the uplight assembly sockets and three 60-watt (maximum) candelabra base lamps in the light kit plate sockets for the lower light. WARNING ! To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling. 9 5. Obtain the die cast glass holders and light kit glass from the protective bags. 6. Position the light kit glass carefully on a convenient surface with the open side face down. 7. Remove the protective cover from the adhesive backed material on the glass holders (Figure 18). PROTECTIVE COVER ON ADHESIVE BACKED MATERIAL DIE CAST Figure 18 GLASS HOLDER 8. Firmly press the die cast glass holders into position on the light kit glass (Figure 19). DIE CAST GLASS HOLDER LIGHT KIT GLASS Figure 19 9. Repeat these procedures for the second die cast holder. 10. Carefully turn the light kit glass assembly over. Thread two knurled knob screws (supplied) several turns onto the die cast glass holders (Figure 20). Leave approximately 3/16” of the stud threads revealed. TURN KNURLED KNOB SCREW SEVERAL TURNS INTO THE GLASS HOLDER LIGHT KIT GLASS DIE-CAST GLASS HOLDER Figure 20 11. Raise the light kit glass assembly and insert the two knurled knobs through the two keyholes in the light kit adapter. Turn the light kit glass assembly counterclockwise to engage the knurled knob screws in the slots (Figure 21). Carefully reach between the fan blade flanges and the light kit glass and securely tighten the two knurled knob screws. LIGHT KIT ADAPTER LIGHT KIT GLASS KNURLED KNOB SCREW ROTATE LIGHT KIT GLASS COUNTERCLOCKWISE VIEWED FROM TOP Figure 21 12. Your ceiling fan is now installed and wired and ready for use. 10 Setting Operating Frequency of Wall Control and Receiver (Figure 22) Your wall control and receiver have code switches which must be set in one of 16 possible code combinations. The four levers (numbered 1, 2, 3, and 4) on the switches are factory-set in the ON (up) position. Change the switch settings as follows: 1. Slide the four switch levers in the wall control to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 2. In the receiver, slide the four switch levers to the same positions as set in the wall cont...

Este manual também é adequado para os modelos :
Fans - CF2455ORB00 (277.5 kb)
Fans - CF2455PW00 (277.5 kb)

Escreva a sua própria avaliação do dispositivo



Mensagem
Seu nome :
Introduza os dois dígitos :
capcha





categorias